215 research outputs found

    The liquid krypton calorimeter cryogenics for the NA48 experiment

    Get PDF
    The NA48 cryogenic system has to provide stable thermal conditions (120 K) in a 9000 liter liquid krypton calorimeter, and has to ensure safe and loss free storage of the liquid during idle periods. Direct cooling of the krypton by nitrogen is used in emergency cases, while an intermediate cooler, containing saturated liquid argon at around 10 bar (117 K) is used under normal operation conditions when high thermal stability is needed. The krypton pressure is, during data taking, regulated to a value of (1.05 ±\pm 0.01) bar for a period of about 8 months of continuous operation of the calorimeter

    Cryogenics for CERN experiments: past, present and future

    Get PDF
    Use of cryogenics at CERN was originated (in the 1960s) by bubble chambers and the associated s.c. solenoids. Complex cryoplants were installed to provide cooling at LH2 and LHe temperatures. Continuity (in the 1970s) in He cryogenics for experiments was provided by spectrometer magnets for fixed target physics of the SPS accelerator. More recently (in the 1980s), large "particle-transparent" s.c. solenoids for collider experiments (LEP) have been built demanding new cryoplants. The LHC experiments (in the 2000s) will continue the tradition with s.c. dipoles (ALICE and LHCb), solenoids (CMS, ATLAS) and toroids (ATLAS) of unusual size. Cryogenics for experiments using noble liquids follows the same trend since the development (in the 1970s) of the first shower LAr detectors. A LKr calorimeter (about 10 m3) will be operated in 1996 and the ATLAS experiment foresees a set of three huge LAr calorimeters (almost 90 m3 total volume of liquid) to be installed underground

    A new measurement of direct CP violation in two pion decays of the neutral kaon

    Get PDF
    The NA48 experiment at CERN has performed a new measurement of direct CP violation, based on data taken in 1997 by simultaneously collecting K_L and K_S decays into pi0pi0 and pi+pi-. The result for the CP violating parameter Re(epsilon'/epsilon) is (18.5 +/- 4.5(stat)} +/- 5.8 (syst))x10^{-4}.Comment: 18 pages, 6 figure

    Surgery, with or without tamoxifen, vs tamoxifen alone for older women with operable breast cancer: Cochrane review

    Get PDF
    The published literature comparing surgery, with or without adjuvant endocrine therapy, with endocrine therapy alone in older women with operable breast cancer was systematically reviewed.The design used is Cochrane review. Randomised controlled trials retrieved from the Cochrane Breast Cancer Group Specialised Register on 29 June 2005. Eligible studies recruited women aged 70 years or over with operable breast cancer, fit for surgery under general anaesthia. The studies compared surgery (either mastectomy or wide local excision, with or without endocrine therapy) to endocrine therapy alone. Primary outcomes were overall survival (OS) and progression-free survival (PFS). Double data extraction and quality assessment were undertaken. Seven eligible trials were identified of which six had published time-to-event data. The quality of the allocation concealment was adequate in three studies and unclear in the remainder. In each case the endocrine therapy used was tamoxifen. When surgery alone was compared to endocrine therapy alone, there was no significant difference in OS (hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.74–1.30, P=0.9), but a significant difference in PFS (HR 0.55, 95% CI 0.39–0.77, P=0.0006). When surgery with adjuvant endocrine therapy was compared to endocrine therapy alone, there was no significant difference in OS (HR 0.86, 95% CI 0.73–1.00, P=0.06), but a significant difference in PFS (HR 0.65 (95% CI 0.53–0.81, P=0.0001) for surgery plus endocrine therapy vs primary endocrine. The regimens have different side effect profiles with one study suggesting increased psychosocial morbidity at 3 months in the surgical arm, which resolves by 2 years. Primary endocrine therapy with tamoxifen is associated with inferior local disease control but non-inferior survival to surgery for breast cancer in older women. Trials are needed to evaluate appropriate selection criteria for its use in terms of patient co-morbidity and quality of life. Trials are needed to evaluate the clinical effectiveness of aromatase inhibitors as primary therapy for this population

    Effect of Activated Carbon Amendment on Bacterial Community Structure and Functions in a PAH Impacted Urban Soil

    Get PDF
    ABSTRACT: We collected urban soil samples impacted by polycyclic aromatic hydrocarbons (PAHs) from a sorbent-based remediation field trial to address concerns about unwanted side-effects of 2 % powdered (PAC) or granular (GAC) activated carbon amendment on soil microbiology and pollutant biodegradation. After three years, total microbial cell counts and respiration rates were highest in the GAC amended soil. The predominant bacterial community structure derived from denaturing gradient gel electrophoresis (DGGE) shifted more strongly with time than in response to AC amendment. DGGE band sequencing revealed the presence of taxa with closest affiliations either to known PAH degraders, e.g. Rhodococcus jostii RHA-1, or taxa known to harbor PAH degraders, e.g. Rhodococcus erythropolis, in all soils. Quantification by real-time polymerase chain reaction yielded similar dioxygenases gene copy numbers in unamended, PAC-, or GACamended soil. PAH availability assessments in batch tests showed th

    A measurement of the transverse polarization of Lambda-hyperons produced in inelastic pN-reactions at 450 GeV proton energy

    Get PDF
    A study of the polarization of Λ hyperons produced in inelastic pN reactions induced by the 450 GeV proton beam from the CERN SPS has been performed with the NA48 detector. The Λ hyperons were detected at a fixed angle of 4.2 mrad in the momentum range from 50 GeV/c to 200 GeV/c. The polarization changes from −0.053 ± 0.034 to −0.298 ± 0.074 for a transverse momentum range of the Λ between 0.28 GeV/c and 0.86 GeV/c. The antiΛ polarization is consistent with zero

    Direct search for light gluinos

    Get PDF
    We present the results for a direct search for light gluinos through the appearance of η3π0\eta\rightarrow 3\pi^{0} with high transverse momentum in the vacuum tank of the NA48 experiment at CERN. We find one event within a lifetime range of 10910310^{-9}-10^{-3}s and another one between 101010910^{-10}-10^{-9}s. Both events are consistent with the expected background from neutrons in the beam, produced by 450 GeV protons impinging on the Be targets, which interact with the residual air in the tank. From these data we give limits on the production of the hypothetical gg~g\widetilde{g} bound state, the R0R^0 hadron, and its R0ηγ~R^0\rightarrow\eta\widetilde{\gamma} decay in the R0R^0 mass range between 1 and 5~GeV

    A new measurement of direct CP violation in two pion decays of the neutral kaon

    Get PDF
    The NA48 experiment at CERN has performed a new measurement of direct CP violation, based on data taken in 1997 by simultaneously collecting KL and KS decays into pi0 pi0 and pi+ pi-. The result for the CP violating parameter Re(epsilon'/epsilon) is (18.5 +- 4.5(stat.) +- 5.8(syst.)) x 10^-4

    The CPLEAR detector at CERN

    Get PDF
    The CPLEAR collaboration has constructed a detector at CERN for an extensive programme of CP-, T- and CPT-symmetry studies using K0{\rm K}^0 and Kˉ0\bar{\rm K}^0 produced by the annihilation of pˉ\bar{\rm p}'s in a hydrogen gas target. The K0{\rm K}^0 and Kˉ0\bar{\rm K}^0 are identified by their companion products of the annihilation K±π{\rm K}^{\pm} \pi^{\mp} which are tracked with multiwire proportional chambers, drift chambers and streamer tubes. Particle identification is carried out with a liquid Cherenkov detector for fast separation of pions and kaons and with scintillators which allow the measurement of time of flight and energy loss. Photons are measured with a lead/gas sampling electromagnetic calorimeter. The required antiproton annihilation modes are selected by fast online processors using the tracking chamber and particle identification information. All the detectors are mounted in a 0.44 T uniform field of an axial solenoid of diameter 2 m and length 3.6 m to form a magnetic spectrometer capable of full on-line reconstruction and selection of events. The design, operating parameters and performance of the sub-detectors are described.

    Futur dels teixits intel·ligents

    Get PDF
    Els teixits intel·ligents del futur es desenvolupen amb nous materials i amb tecnologies innovadores, però també amb clau d'eficiència ambiental. Es revisen tendències de la indústria tèxtil relacionades, entre d'altres, amb: Teixits funcionals i materials amb propietats singulars. e-Textil, wearables i gestió 4.0. Automatització, robòtica i impressió 3D. Ecologia industrial, impacte ambiental i valorització energètic
    corecore