37 research outputs found

    Exploring consensus on preventive measures and identification of patients at risk of age-related macular degeneration using the delphi process

    Get PDF
    Background: Early identification of AMD can lead to prompt and more effective treatment, better outcomes, and better final visual acuity; several risk scores have been devised to determine the individual level of risk for developing AMD. Herein, the Delphi method was used to provide recommendations for daily practice regarding preventive measures and follow-up required for subjects at low, moderate, and high risk of AMD evaluated with the Simplified Test AMD Risk-assessment Scale (STARS® ) questionnaire. Methods: A steering committee of three experts drafted and refined 25 statements on the approach to be recommended in different clinical situations [general recommendations (n = 2), use of evaluation tools (n = 4), general lifestyle advice (n = 3), and AREDS-based nutritional supplementation (n = 5)] with the help of a group of international experts, all co-authors of this paper. Thirty retinal specialists from Europe and the US were chosen based on relevant publications, clinical expertise, and experience in AMD, who then provided their level of agreement with the statements. Statements for which consensus was not reached were modified and voted upon again. Results: In the first round of voting, consensus was reached for 24 statements. After modification, consensus was then reached for the remaining statement. Conclusion: An interprofessional guideline to support preventive measures in patients at risk of AMD based on STARS® scoring has been developed to aid clinicians in daily practice, which will help to optimize preventive care of patients at risk of AMD

    Tono-Pen XL tonometry during application of a suction ring in rabbits

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study is to evaluate the use of Tono-Pen XL in measuring IOP during the application of a suction ring in rabbit eyes with manometrically controlled IOP.</p> <p>Methods</p> <p>Tono-Pen XL was calibrated against direct manometry in 10 rabbit eyes. A suction ring was then applied in 4 rabbit eyes and the IOP was determined manometrically during suction ring application at 350 mmHg vacuum pressure. Finally, in 6 catheterized rabbit eyes the IOP was measured with Tono-Pen XL during suction ring application at suction vacuum from 350 to 650 mmHg, while keeping actual IOP stable at 30 mmHg and 60 mmHg.</p> <p>Results</p> <p>Linear regression analysis revealed that the Tono-pen XL was reliable for IOPs between 10 and 70 mmHg (R<sup>2 </sup>= 0.9855). Direct manometry during suction ring application showed no statistically significant variation of Tono-Pen XL readings when the incanulation manometry intraocular pressure changed from 30 mmHg to 60 mmHg and no statistically significant correlation between suction vacuum and IOP measurements.</p> <p>Conclusion</p> <p>Tono-Pen XL measurements are unreliable during the application of a suction ring on living rabbit eyes even when the actual IOP is forced to be within the validated range of Tono-Pen XL measurements. This inaccuracy is probably related to altered corneal and scleral geometry and stress.</p

    Retinal vessel diameters and reactivity in diabetes mellitus and/or cardiovascular disease

    Get PDF
    Background: Retinal vessel calibre and vascular dilation/constriction in response to flicker light provocation may provide a measure distinguishing patients suffering from diabetes mellitus and/or cardiovascular disease. Methods: One hundred and sixteen age and sex matched patients with diabetes mellitus (DM), cardiovascular disease (CVD) and both DM and CVD (DM+CVD) underwent systemic and intraocular pressure measurements. Retinal vessel calibres were assessed using a validated computer-based program to compute central retinal artery and vein equivalents (CRVE) from monochromatic retinal images. Vessel dilation and constriction responses to flicker light provocation were assessed by continuous retinal vessel diameter recordings. Plasma endothelial markers von Willebrand factor (vWf) and soluble E selectin (sEsel) were measured by ELISA. Results: Retinal vessel calibres were comparable across groups but CRVE correlated significantly with disease duration in DM patients (r=0.57, p<0.001). Patients suffering DM only exhibited reduced arterial vasomotion at rest and reduced arterial constriction following flicker light induced vessel dilation compared to patients with CVD and those suffering both CVD+DM (p=0.030). Patients suffering from CVD+DM exhibited significant differences between each flicker cycle in regards to arterial maximum constriction (p=0.006) and time needed to reach arterial maximum dilation (p=0.004), whereas the other two groups did not show such inconsistencies between individual flicker cycles. vWf was raised in CVD+DM compared to the other two groups (p≤0.02), whilst sEsel was raised in CVD+DM compared to DM alone (p=0.044). Conclusions: Dynamic retinal vascular calibres as obtained by continuous diameter measurements using flicker light provocation can reveal subtle differences between groups suffering from CVD with and without DM. This difference in reaction pattern and lack of arterial constriction in DM may provide a suitable marker to monitor progression

    Overweight status is associated with extensive signs of microvascular dysfunction and cardiovascular risk

    Get PDF
    The aim of this present study was to investigate if overweight individuals exhibit signs of vascular dysfunction associated with a high risk for cardiovascular disease (CVD). One hundred lean and 100 overweight participants were recruited for the present study. Retinal microvascular function was assessed using the Dynamic Retinal Vessel Analyser (DVA), and systemic macrovascular function by means of flow-mediated dilation (FMD). Investigations also included body composition, carotid intimal-media thickness (c-IMT), ambulatory blood pressure monitoring (BP), fasting plasma glucose, triglycerides (TG), cholesterol levels (HDL-C and LDL-C), and plasma von Willebrand factor (vWF). Overweight individuals presented with higher right and left c-IMT (p = 0.005 and p = 0.002, respectively), average 24-h BP values (all p <0.001), plasma glucose (p = 0.008), TG (p = 0.003), TG: HDL-C ratio (p = 0.010), and vWF levels (p = 0.004). Moreover, overweight individuals showed lower retinal arterial microvascular dilation (p = 0.039) and baseline-corrected flicker (bFR) responses (p = 0.022), as well as, prolonged dilation reaction time (RT, p = 0.047). These observations emphasise the importance of vascular screening and consideration of preventive interventions to decrease vascular risk in all individuals with adiposity above normal range

    Rationale and study design of the prospective, longitudinal, observational cohort study “rISk strAtification in end-stage renal disease” (ISAR) study

    Get PDF
    Background: The ISAR study is a prospective, longitudinal, observational cohort study to improve the cardiovascular risk stratification in endstage renal disease (ESRD). The major goal is to characterize the cardiovascular phenotype of the study subjects, namely alterations in micro-and macrocirculation and to determine autonomic function. Methods/design: We intend to recruit 500 prevalent dialysis patients in 17 centers in Munich and the surrounding area. Baseline examinations include: (1) biochemistry, (2) 24-h Holter Electrocardiography (ECG) recordings, (3) 24-h ambulatory blood pressure measurement (ABPM), (4) 24 h pulse wave analysis (PWA) and pulse wave velocity (PWV), (5) retinal vessel analysis (RVA) and (6) neurocognitive testing. After 24 months biochemistry and determination of single PWA, single PWV and neurocognitive testing are repeated. Patients will be followed up to 6 years for (1) hospitalizations, (2) cardiovascular and (3) non-cardiovascular events and (4) cardiovascular and (5) all-cause mortality. Discussion/conclusion: We aim to create a complex dataset to answer questions about the insufficiently understood pathophysiology leading to excessively high cardiovascular and non-cardiovascular mortality in dialysis patients. Finally we hope to improve cardiovascular risk stratification in comparison to the use of classical and non-classical (dialysis-associated) risk factors and other models of risk stratification in ESRD patients by building a multivariable Cox-Regression model using a combination of the parameters measured in the study

    The relationship of systemic markers of renal function and vascular function with retinal blood vessel responses

    Get PDF
    Purpose: To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease.Methods: Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index.Results: Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p<0.05). Arterial reaction time was linked to serum creatinine (p=0.036) and eGFR (p=0.039), venous reaction time was linked to creatinine clearance (p=0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p<0.001 and p=0.003 respectively) and the dilatation amplitude (p=0.038 and p=0.048 respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p=0.004) and dilatation amplitude (p=0.017), vWf was linked to the maximum constriction response (p=0.016), and creatinine clearance to the baseline diameter fluctuation (p=0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p=0.022). Conclusions: Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses

    Strategies for reducing variance in laser Doppler flowmetry measurements

    No full text
    BACKGROUND: Scattering of blood flow data as assessed with laser Doppler flowmetry (LDF) in humans is a problem in many studies using this technique. We set out to reduce variability in LDF data by eliminating the effect of the total returning light level (DC) on LDF parameters in the choroid through partial regression analysis. METHODS: In 20 healthy subjects, choroidal blood flow parameters were measured at different DC values using a portable confocal LDF device. We used two different strategies to reduce scattering of data eliminating the effect of yield, which is defined as DC/gain. On the one hand, we used a previously described method based on a third-order polynomial fit, which combines all obtained data. On the other hand, we applied a new method based on a linear fit for each individual subject. RESULTS: Variability of data during changes in DC is higher for LDF parameters volume and flow than for velocity. Both methods were successful in reducing scattering of LDF parameters with varying DC. CONCLUSIONS: The present study indicates that both methods to correct for changes in yield were successful in reducing the variability of LDF measurements. When systematic changes in DC occur after an intervention, one needs to be careful in interpreting the obtained data and it remains to be shown if either of the two techniques is capable of correcting for this effect. The approach presented here may, however, represent an effective, easily applicable and valid approach to reduce scattering of data from using LDF to assess blood flow in the posterior pole of the human eye