28,471 research outputs found
Integrating IR detector imaging systems
An integrating IR detector array for imaging is provided in a hybrid circuit with InSb mesa diodes in a linear array, a single J-FET preamplifier for readout, and a silicon integrated circuit multiplexer. Thin film conductors in a fan out pattern deposited on an Al2O3 substrate connect the diodes to the multiplexer, and thick film conductors also connect the reset switch and preamplifier to the multiplexer. Two phase clock pulses are applied with a logic return signal to the multiplexer through triax comprised of three thin film conductors deposited between layers. A lens focuses a scanned image onto the diode array for horizontal read out while a scanning mirror provides vertical scan
Failure assessment of lightly reinforced floor slabs. I: Experimental investigation
This paper is concerned with the ultimate behavior of lightly reinforced concrete floor slabs under extreme loading conditions. Particular emphasis is given to examining the failure conditions of idealized composite slabs which become lightly reinforced in a fire situation as a result of the early loss of the steel deck. An experimental study is described which focuses on the response of two-way spanning floor slabs with various materials and geometric configurations. The tests enable direct assessment of the influence of a number of key parameters such as the reinforcement type, properties, and ratio on the ultimate response. The results also permit the development of simplified expressions that capture the influence of salient factors such as bond characteristics and reinforcement properties for predicting the ductility of lightly reinforced floor slabs. The companion paper complements the experimental observations with detailed numerical assessments of the ultimate response and proposes analytical models that predict failure of slab members by either reinforcement fracture or compressive crushing of concrete. © 2011 American Society of Civil Engineers
Recommended from our members
Influence of surgery and rehabilitation conditioning on psychophysiological fitness
The purpose of this study was to assess changes in psychophysiological fitness following reconstructive knee surgery and early phase (2.5 months) physical rehabilitation. Nine patients (7 male, 2 female; mean age, 29.9 years) electing to undergo anterior cruciate ligament reconstructive surgery (central third, bone-patella tendon-bone graft) were assessed on four separate assessment occasions post-surgery. Repeated measures ANOVAs showed significant condition (injured/non-injured leg) by test occasion (2 weeks pre-surgery and 6, 8 and 10 weeks post-surgery) interactions for knee ligamentous compliance (anterior tibiofemoral displacement), peak force and electromechanical delay associated with the knee flexors of the injured and noninjured legs (F3,24 = 4.7 to 6.6; p < 0.01), together with individualized emotional profile disturbance scores that were significantly less at 10 weeks post-surgery compared to pre-surgery, 6 weeks and 8 weeks post-surgery (F3,24 = 7.6; p < 0.01). Spearman rank correlation coefficients identified significant relationships between musculoskeletal fitness and emotional profile scores at pre-surgery (r = 0.69–0.72; p < 0.05) and at 8 weeks post-surgery (r = 0.70–0.73; p < 0.05). The 6 Bi-POMS subscales and the 12 ERAIQ responses found inconsistent patterns of response and relationships across the assessment occasions. Overall, the patterning of changes and associations amongst emotional performance profile discrepancy scores in conjunction with those scores from indices of musculoskeletal fitness performance capability offered important support for the efficacy of an approach which integrates self-perceptive and objective measurements of fitness capability during rehabilitation following surgery to a synovial joint
Recommended from our members
An Evaluation of a Battery of Functional and Structural Tests as Predictors of Likely Risk of Progression of Age-Related Macular Degeneration.
Purpose: To evaluate the ability of visual function and structural tests to identify the likely risk of progression from early/intermediate to advanced AMD, using the Age-Related Eye Disease Study (AREDS) simplified scale as a surrogate for risk of progression. The secondary aim was to determine the relationship between disease severity grade and the observed functional and structural deficits. Methods: A total of 100 participants whose AMD status varied from early to advanced were recruited. Visual function was assessed using cone dark adaptation, 14 Hz flicker and chromatic threshold tests and retinal structure was assessed by measuring drusen volume and macular thickness. The predictive value of the tests was estimated using ordinal regression analysis. Group comparisons were assessed using analysis of covariance. Results: Change in cone dark adaptation (cone τ) and yellow-blue (YB) chromatic sensitivity were independent predictors for AMD progression risk (cone τ, pseudo R2 = 0.35, P < 0.001; YB chromatic threshold, pseudo R2 = 0.16, P < 0.001). The only structural predictor was foveal thickness (R2 = 0.05, P = 0.047). Chromatic sensitivity and cone dark adaptation were also the best functional tests at distinguishing between severity groups. Drusen characteristics clearly differentiated between participants with early and advanced disease, but were not able to differentiate between those with early AMD and controls. Mean differences in retinal thickness existed between severity groups at the foveal (P = 0.040) and inner (P = 0.001) subfields. Conclusions: This study indicates that cone τ, YB chromatic threshold and foveal thickness are independent predictors of likely risk of AMD progression
Ks band secondary eclipses of WASP-19b and WASP-43b with the Anglo-Australian Telescope
We report new Ks band secondary eclipse observations for the hot-Jupiters
WASP-19b and WASP-43b. Using the IRIS2 infrared camera on the Anglo-Australian
Telescope (AAT), we measured significant secondary eclipses for both planets,
with depths of 0.287 -0.020/+0.020% and 0.181 -0.027/+0.027% for WASP-19b and
WASP-43b respectively. We compare the observations to atmosphere models from
the VSTAR line-by-line radiative transfer code, and examine the effect of C/O
abundance, top layer haze, and metallicities on the observed spectra. We
performed a series of signal injection and recovery exercises on the observed
light curves to explore the detection thresholds of the AAT+IRIS2 facility. We
find that the optimal photometric precision is achieved for targets brighter
than Kmag = 9, for which eclipses as shallow as 0.05% are detectable at >5
sigma significance.Comment: Accepted for publication in MNRAS, 13 pages, 10 figure
FEEDER CATTLE PRICE SLIDES
A theoretical model is developed to explain the economics of determining price slides for feeder cattle. The contract is viewed as a dynamic game with continuous strategies where the buyer and seller are the players. The model provides a solution for the price slide that guarantees an unbiased estimate of cattle weight. An empirical model using Superior Livestock Auction (SLA) data shows price slides used are smaller than those needed to cause the producer to give unbiased estimates of weight. Consistent with the model's predictions, producers slightly underestimate cattle weights.Demand and Price Analysis,
Experimental investigation of open-ended microwave oven assisted encapsulation process
An open ended microwave oven is presented with improved uniform heating, heating rates and power conversion efficiency. This next generation oven produces more uniform EM fields in the evanescent region forming part of the heating area of the oven. These fields are vital for the rapid and uniform heating of various electromagnetically lossy materials. A fibre optic temperature sensor and an IR pyrometer are used to measure in situ and in real-time the temperature of the curing materials. An automatic computer controlled closed feedback loop measures the temperature in the curing material and drives the microwave components to
obtain predetermined curing temperature cycles for efficient curing. Uniform curing of the lossy encapsulants
is achieved with this oven with typical cure cycle of 270
seconds with a ramp rate of 1oC/s and a hold period of 2
minutes. Differential scanning calorimeter based measurement for the pulsed microwave based curing of
the polymer dielectric indicates a ~ 100% degree of cure
An Experimental Investigation of Wing-Tip Vortex Decay in Turbulence
Particle image velocimetry measurements were conducted for a wing-tip vortex decaying in free-stream turbulence. The vortex exhibited stochastic collapse with free-stream turbulence present, with the breakdown initiating earlier for higher levels of turbulence. An increased rate of decay of the vortex tangential velocity was also observed, increasing with increasing free-stream turbulence. The decay of the vortex tangential velocity without the free-stream turbulence was well represented by viscous diffusion, resulting in an increase in the core radius and decrease in the peak tangential velocity. With the addition of free-stream turbulence, the rate of decay of the peak tangential velocity of the vortex increases, whereas the rate of increase of core radius remains unchanged. The circulation of the vortex decayed in time when immersed in free-stream turbulence, whereas it remained approximately constant when free-stream turbulence was not present. This decay in circulation was found to be almost entirely due to a decrease in circulation of the vortex core, caused by the relative decrease in the peak tangential velocity without a corresponding increase in the core radius. The scaling of the radial profiles of velocity and circulation was also examined, and it was found that, regardless of the free-stream condition, the core was scaled by the peak tangential velocity and core radius. The region outside the core did not scale with these quantities, and an alternative scaling for circulation is proposed which results in improved collapse of the profiles
- …