1,252 research outputs found

    Safety level assessment of segmental linings in rock

    Get PDF

    Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

    Get PDF
    We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of 1.5⋅10−20Hz−1/21.5\cdot 10^{-20} Hz^{-1/2} at 2942.9 Hz. A strain sensitivity of better than 5⋅10−20Hz−1/25\cdot 10{-20}Hz{-1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than one order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3kHz range.Comment: 8 pages, 5 figures, submitted to Physical Review

    Optical absorption parameters of amorphous carbon films from Forouhi–Bloomer and Tauc–Lorentz models: a comparative study

    Get PDF
    International audienceParametrization models of optical constants, namely Tauc-Lorentz (TL), Forouhi-Bloomer (FB) and modified FB models, were applied to the interband absorption of amorphous carbon films. The optical constants were determined by means of transmittance and reflectance measurements in the visible range. The studied films were prepared by rf sputtering and characterized for their chemical properties. The analytical models were also applied to other optical data published in the literature pertaining to films produced by various deposition techniques. The different approaches used to determine important physical parameters of the interband transition yielded different results. A figure-of-merit was introduced to check the applicability of the models and the results showed that FB modified for an energy dependence of the dipole matrix element adequately represents the interband transition in the amorphous carbons. Further, the modified FB model shows a relative superiority over the TL ones for concerning the determination of the band gap energy, as it is the only one to be validated by an independent, though indirect, gap measurement by x-ray photoelectron spectroscopy. Finally, the application of the modified FB model allowed us to establish some important correlations between film structure and optical absorption properties

    Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory

    Full text link
    Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a field of view with a diameter of of 5 arc minutes. Multiplexed readout of the cryogenic microcalorimeter array is essential to comply with the cooling power and complexity constraints on a space craft. Frequency domain multiplexing has been under development for the readout of TES-based detectors for this purpose, not only for the X-IFU detector arrays but also for TES-based bolometer arrays for the Safari instrument of the Japanese SPICA observatory. This paper discusses the design considerations which are applicable to optimise the multiplex factor within the boundary conditions as set by the space craft. More specifically, the interplay between the science requirements such as pixel dynamic range, pixel speed, and cross talk, and the space craft requirements such as the power dissipation budget, available bandwidth, and electromagnetic compatibility will be discussed

    The Garisenda Tower in Bologna: Effects of degradation of selenite basement on its static behaviour

    Get PDF
    The Garisenda tower in Bologna, a 48 m tall structure with a square base of 7.45 meters per side, is characterized by an overall out of plumb of 3.32m in the South-East direction. Its construction dates back to the XI century and, due to its impressive leaning, in 1350–1353 the original height of 60m was reduced to the 48m of the present day (Cavani 1903; Giordano 2000). The tower can be seen as partitioned in a lower portion, with walls composed by two external leaves of selenite stones filled with rubble conglomerate, and an upper portion where the external leaves are made of masonry bricks. Recent investigations have proved that selenite blocks of the basement have been altered as a result of (a) exposition to high temperatures during important fires, that took place at the end of XIV and XVII centuries, and possibly because of the presence of forges (that were demolished at the end of the XIX centuries) and (b) high level of humidity in the inner lower part of the tower. This process has produced a gradual local disintegration of the selenite stones, leading in some case to a reduction of the original 50 to 60 cm thickness by an amount of about 20 cm. The contribution submitted to this conference is aimed at clarifying this important aspect, linked to the ageing and damage of structural stones and the related consequences in terms of stress distribution and concentrations that could induce fracture propagation and sudden collapse of the tower basement

    Fibrosis in systemic sclerosis: common and unique pathobiology

    Get PDF
    Fibrosis in systemic sclerosis (SSc), a complex polygenic disease associated with autoimmunity and proliferative/obliterative vasculopathy, shares pathobiologic features in common with other fibrosing illnesses, but also has distinguishing characteristics. Fibroblast activation induced by transforming growth factor-β (TGF-β), Wnts and innate immune receptors, along with oxidative stress and reactive oxygen species (ROS) are implicated in pathogenesis. On the other hand, the roles of endothelial-mesenchymal differentiation and bone marrow-derived fibrocytes remain to be established. Fibrotic responses are modulated by transcriptional activators and cofactors, epigenetic factors, and microRNAs that can amplify or inhibit ligand-induced signaling. The nuclear orphan receptor PPAR-γ appears to be important in governing the duration and intensity of fibroblast activation and mesenchymal progenitor cell differentiation, and defects in PPAR-γ expression or function in SSc may underlie the uncontrolled progression of fibrosis. Identifying the perturbations in signaling pathways and cellular differentiation programs responsible for tissue damage and fibrosis in SSc allows their selective targeting using novel compounds, or by innovative uses of already-approved drugs (drug repurposing)
    • …