378 research outputs found

    A New Anisotropic Four-Parameter Turbulence Model for Low Prandtl Number Fluids

    Get PDF
    Due to their interesting thermal properties, liquid metals are widely studied for heat transfer applications where large heat fluxes occur. In the framework of the Reynolds-Averaged Navier– Stokes (RANS) approach, the Simple Gradient Diffusion Hypothesis (SGDH) and the Reynolds Analogy are almost universally invoked for the closure of the turbulent heat flux. Even though these assumptions can represent a reasonable compromise in a wide range of applications, they are not reliable when considering low Prandtl number fluids and/or buoyant flows. More advanced closure models for the turbulent heat flux are required to improve the accuracy of the RANS models dealing with low Prandtl number fluids. In this work, we propose an anisotropic four-parameter turbulence model. The closure of the Reynolds stress tensor and turbulent heat flux is gained through nonlinear models. Particular attention is given to the modeling of dynamical and thermal time scales. Numerical simulations of low Prandtl number fluids have been performed over the plane channel and backward-facing step configurations

    The AMS-02 Time of Flight System. Final Design

    Full text link
    The AMS-02 detector is a superconducting magnetic spectrometer that will operate on the International Space Station. The time of flight (TOF) system of AMS-02 is composed by four scintillator planes with 8, 8, 10, 8 counters each, read at both ends by a total of 144 phototubes. This paper describes the new design, the expected performances, and shows preliminary results of the ion beam test carried on at CERN on October 2002.Comment: 4 pages, 6 EPS figures. Proc. of the 28th ICRC (2003

    The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -

    Full text link
    A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by means of a low intensity 20 GeV/c per nucleon ion beam obtained by fragmentation of a primary beam of Pb ions. Data have been collected with a single beam setting, over the range of nuclear charges 2<Z<~45 in various beam conditions and using different radiators. The charge Z and velocity beta resolutions have been measured.Comment: 4 pages, contribution to the ICRC 200

    Potentiometric measurement of urinary iodine concentration in patients with thyroid diseases with and without previous exposure to non-radioactive iodine

    Get PDF
    Background: Extensive application of measurement of urinary iodine concentration (UIC) in several benign and malignant thyroid diseases could profit by the availability of rapid and inexpensive measuring techniques. Aim of this study was to apply a simple and inexpensive commercially available potentiometric method for the quantification of UIC based on iodine-specific ion-selective electrodes (ISE) in patients with thyroid diseases. Methods: This retrospective study included patients with differentiated thyroid cancer (n=286) and patients with hyperthyroidism of different etiologies (n=203). Within the whole sample (n=489) 20 patients had previously (1 week-6 months) been exposed to iodine overload, either from contrast media (n=8) or amiodarone (n=12). Results: In patients not exposed to iodine, the histogram showed that the distribution of UIC violated normality. The peak of the curve occurred between 5.0 ÎĽmol/L and 6.0 ÎĽmol/L. Variability was sizeable (percent coefficient of variation, %CV: 66%, 95% confidence interval: 1.48-18.72 ÎĽmol/L). The group of exposed patients could be easily distinguished from not exposed patients (median UIC: 47.5 ÎĽmol/L vs. 5.42 ÎĽmol/L). UIC was significantly correlated to urinary creatinine concentration, but normalization to urinary creatinine increased the inter-subject variability of UIC (%CV=96% vs. 66%). In test-retest studies (n=25) the intra-class correlation coefficient was 0.73 for UIC, 0.82 for creatinine and 0.64 for the UIC: creatinine ratio. Conclusions: Iodine-specific ISE-based potentiometric methods can be successfully applied as an alternative to existing methods in patients with thyroid diseases. The promising characteristics of the method need to be confirmed in future larger prospective studies

    The Ring Imaging Cherenkov detector (RICH) of the AMS experiment

    Full text link
    The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and velocity of the charged cosmic particles. A RICH prototype consisting of 96 photomultiplier units, including a piece of the conical reflector, was built and its performance evaluated with ion beam data. Preliminary results of the in-beam tests performed with ion fragments resulting from collisions of a 158 GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported. The collected data included tests to the final front-end electronics and to different aerogel radiators. Cherenkov rings for a large range of charged nuclei and with reflected photons were observed. The data analysis confirms the design goals. Charge separation up to Fe and velocity resolution of the order of 0.1% for singly charged particles are obtained.Comment: 29th International Conference on Cosmic Rays (Pune, India

    Lower-limb amputees can reduce the energy cost of walking when assisted by an Active Pelvis Orthosis

    Get PDF
    Exoskeletons could compete with active prostheses as effective aids to reduce the increased metabolic demands faced by lower-limb amputees during locomotion. However, little evidence of their efficacy with amputees has been provided so far. In this paper, a portable hip exoskeleton has been tested with seven healthy subjects and two transfemoral amputees, with the final goal to verify whether a hip flexion-extension assistance could be effective in reducing the metabolic cost of walking. The metabolic power of the participants was estimated through indirect calorimetry during alternated repetitions of three treadmill-based walking conditions: without the exoskeleton (NoExo), with the exoskeleton in zero-torque mode (ExoTM) and with the exoskeleton providing hip flexion-extension assistance (ExoAM). The results showed that the exoskeleton reduced the net metabolic power of the two amputees in ExoAM with respect to NoExo, by 5.0% and 3.4%. With healthy subjects, a 5.5±3.1% average reduction in the metabolic power was observed during ExoAM compared to ExoTM (differences were not statistically significant), whereas ExoAM required 3.9±3.0% higher metabolic power than NoExo (differences were not statistically significant). These results provide initial evidence of the potential of exoskeletal technologies for assisting lower-limb amputees, thereby paving the way for further experimentations

    NEWS AND NOTES 1994, VOL.4, NO.16

    Get PDF
    https://digitalcommons.rockefeller.edu/news_and_notes_1994/1002/thumbnail.jp

    The TOF counters of the AMS-02 experiment: space qualification tests and beam test results

    Get PDF
    The scintillator counters of the TOF system of AMS-02 is beeing constructed to match the needs of the AMS-02 experiment that is armed by a high aperture superconducting dipole magnet. The goals of the TOF-02 hodoscopes actually are: to give the fast trigger to the all sub-detectors of AMS-02; to measure the particle velocity ensuring a 1 Ă— 10 9 albedo rejection; to measure the absolute charge by particle energy loss, up to at least Z = 20 . In spring of 2005 all the TOF counter planes will be assembled and the space qualification tests will be performed. A description of the first test results and of the TOF performances will be given

    Robot-mediated overground gait training for transfemoral amputees with a powered bilateral hip orthosis: a pilot study

    Get PDF
    Background: Transfemoral amputation is a serious intervention that alters the locomotion pattern, leading to secondary disorders and reduced quality of life. The outcomes of current gait rehabilitation for TFAs seem to be highly dependent on factors such as the duration and intensity of the treatment and the age or etiology of the patient. Although the use of robotic assistance for prosthetic gait rehabilitation has been limited, robotic technologies have demonstrated positive rehabilitative effects for other mobility disorders and may thus offer a promising solution for the restoration of healthy gait in TFAs. This study therefore explored the feasibility of using a bilateral powered hip orthosis (APO) to train the gait of community-ambulating TFAs and the effects on their walking abilities. Methods: Seven participants (46–71&nbsp;years old with different mobility levels) were included in the study and assigned to one of two groups (namely Symmetry and Speed groups) according to their prosthesis type, mobility level, and prior experience with the exoskeleton. Each participant engaged in a maximum of 12 sessions, divided into one Enrollment session, one Tuning session, two Assessment sessions (conducted before and after the training program), and eight Training sessions, each consisting of 20&nbsp;minutes of robotically assisted overground walking combined with additional tasks. The two groups were assisted by different torque-phase profiles, aiming at improving symmetry for the Symmetry group and at maximizing the net power transferred by the APO for the Speed group. During the Assessment sessions, participants performed two 6-min walking tests (6mWTs), one with (Exo) and one without (NoExo) the exoskeleton, at either maximal (Symmetry group) or self-selected (Speed group) speed. Spatio-temporal gait parameters were recorded by commercial measurement equipment as well as by the APO sensors, and metabolic efficiency was estimated via the Cost of Transport (CoT). Additionally, kinetic and kinematic data were recorded before and after treatment in the NoExo condition. Results: The one-month training protocol was found to be a feasible strategy to train TFAs, as all participants smoothly completed the clinical protocol with no relevant mechanical failures of the APO. The walking performance of participants improved after the training. During the 6mWT in NoExo, participants in the Symmetry and Speed groups respectively walked 17.4% and 11.7% farther and increased walking speed by 13.7% and 17.9%, with improved temporal and spatial symmetry for the former group and decreased energetic expenditure for the latter. Gait analysis showed that ankle power, step width, and hip kinematics were modified towards healthy reference levels in both groups. In the Exo condition metabolic efficiency was reduced by 3% for the Symmetry group and more than 20% for the Speed group. Conclusions: This study presents the first pilot study to apply a wearable robotic orthosis (APO) to assist TFAs in an overground gait rehabilitation program. The proposed APO-assisted training program was demonstrated as a feasible strategy to train TFAs in a rehabilitation setting. Subjects improved their walking abilities, although further studies are required to evaluate the effectiveness of the APO compared to other gait interventions. Future protocols will include a lighter version of the APO along with optimized assistive strategies

    Isotopic Composition of Light Nuclei in Cosmic Rays: Results from AMS-01

    Get PDF
    The variety of isotopes in cosmic rays allows us to study different aspects of the processes that cosmic rays undergo between the time they are produced and the time of their arrival in the heliosphere. In this paper we present measurements of the isotopic ratios 2H/4He, 3He/4He, 6Li/7Li, 7Be/(9Be+10Be) and 10B/11B in the range 0.2-1.4 GeV of kinetic energy per nucleon. The measurements are based on the data collected by the Alpha Magnetic Spectrometer, AMS-01, during the STS-91 flight in 1998 June.Comment: To appear in ApJ. 12 pages, 11 figures, 6 table
    • …
    corecore