467 research outputs found

    Primary gas thermometry by means of laser-absorption spectroscopy: Determination of the Boltzmann constant

    Full text link
    We report on a new optical implementation of primary gas thermometry based on laser absorption spectrometry in the near infrared. The method consists in retrieving the Doppler broadening from highly accurate observations of the line shape of the R(12) ν1+2ν210+ν3\nu_{1} + 2 \nu_{2}^{\phantom{1}0} + \nu_{3} transition in CO2_{2} gas at thermodynamic equilibrium. Doppler width measurements as a function of gas temperature, ranging between the triple point of water and the gallium melting point, allowed for a spectroscopic determination of the Boltzmann constant with a relative accuracy of ∼1.6×10−4\sim1.6\times10^{-4}.Comment: Submitted to Physical Review Letter

    Early Experience with the New Ovation Alto Stent Graft in Endovascular Abdominal Aortic Aneurysm Repair

    Get PDF
    Introduction: Since 2010, the Ovation Abdominal Stent Graft System has offered a new sealing concept, achieved by a sealing ring filled with polymer 13 mm from the renal arteries. In the latest version, called Ovation Alto, the sealing ring is relocated 6 mm closer to the top of the fabric. This study describes the early clinical outcomes, after CE Mark approval in August 2020, of endovascular aneurysm repair with the Alto endograft. Report: Eleven patients underwent endovascular aneurysm repair with implantation of Ovation Alto endografts. All patients were male, and the median age was 75 (IQR 5.5) years. Hostile proximal aortic neck (<10 mm) was identified in six cases (54.5%). All procedures were performed using bilateral percutaneous approaches with no groin complications. The median procedure time was 58 (IQR 7.2) minutes, the median contrast volume used was 65 (IQR 4.2) mL, and the median blood loss 40 (IQR 12.4) mL. Technical success was achieved in all cases. The median stent graft landing distance between the top of the fabric and the lowest renal artery was 1.4 (IQR 0.8) mm. No intra-operative high flow endoleaks were registered. At one and six month follow up, there was 100% clinical success (no type I/III endoleak, sac enlargement, stent graft migration, polymer leakage, abdominal aortic aneurysm related mortality, or secondary intervention). Discussion: Initial experience confirms the early technical and clinical success of the new Ovation Alto stent graft. Technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on label. Further studies are needed to evaluate long term durability outcomes

    Optical Coherence Tomography after Carotid Stenting: Rate of Stent Malapposition, Plaque Prolapse and Fibrous Cap Rupture According to Stent Design

    Get PDF
    ObjectivesThis study aims to evaluate the rate of stent malapposition, plaque prolapse and fibrous cap rupture detected by optical coherence tomography (OCT) imaging according to carotid stent design.DesignIt was a prospective single-centre study.Materials and methodsForty consecutive patients undergoing protected carotid artery stenting (CAS) and high-definition OCT image acquisition were enrolled in the study. OCT frames were analysed off-line, in a dedicated core laboratory by two independent physicians. Cross-sectional OCT images within the stented segment of the internal carotid artery were evaluated at 1-mm intervals for the presence of strut malapposition, plaque prolapse and fibrous cap rupture according to stent design.ResultsClosed-cell design stents (CC) were used in 17 patients (42.5%), open-cell design stents (OC) in 13 (32.5%) and hybrid design stents (Hyb) in 10 (25%). No procedural or post-procedural neurological complications occurred (stroke/death 0% at 30 days). On OCT analysis the frequencies of malapposed struts were higher with CC compared to OC and Hyb (34.5% vs 15% and 16.3%, respectively; p < 0.01). Plaque prolapse was more frequent with OC vs CC (68.6% vs 23.3%; p < 0.01) and vs Hyb stents (30.8%; p < 0.01). Significant differences were also noted in the rates of fibrous cap rupture between CC and OC (24.2% vs 43.8%; p < 0.01), and between CC and Hyb (24.2% vs 39.6%; p < 0.01), but not between OC and Hyb stents (p = 0.4).ConclusionIntravascular OCT after CAS revealed that micro-defects after stent deployment are frequent and are related to the design of implanted stents. Stent malapposition is more frequent with CC stents, while plaque prolapse is more common with OC stents.It remains, however, unknown whether these figures now detected with OCT are of any clinical and prognostic significance

    High Neutrophil-to-Lymphocyte and Platelet-to-Lymphocyte Ratios Are Associated with a Higher Risk of Hemodialysis Vascular Access Failure

    Get PDF
    Our aim was to determine the predictive role of the preoperative neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) in vascular access malfunctioning in patients who had undergone their first native arterio-venous fistula (AVF) for hemodialysis. Methods: This was a single-center retrospective observational study. All patients who underwent the procedure of the creation of a first native AVF for hemodialysis from January 2019 to December 2020 were considered eligible to be part of this study. Reinterventions for AVF malfunctioning were registered and the population was subdivided into two groups with respect to AVF malfunctioning. ROC curves were obtained to find the appropriate cut-off values for the NLR and PLR. A multivariate analysis was used to identify the independent predictors for an AVF malfunction. Kaplan–Meier curves were used to evaluate the AVF patency rates. A total of 178 patients were enrolled in the study, of them 70% (n = 121) were male. The mean age was 67.5 ± 12 years. Reinterventions for AVF malfunctioning were performed on 102 patients (57.3%). An NLR &gt; 4.21 and a PLR &gt; 208.8 was selected as the cut-off for AVF malfunctioning. The study population was divided into two groups depending on the NLR and PLR values of the individual. For the NLR &lt; 4.21 group, the AVF patency rates were 90.7%, 85.3%, and 84% at the 3-, 6-, and 12-month follow-up, respectively, and 77.5%, 65.8%, and 39.3% at 3, 6, and 12 months for the NLR &gt; 4.21 group, respectively (p &lt; 0.0001). For the PLR &lt; 208.8 group, the patency rates were 85.6%, 76.7%, and 67.7% at the 3-, 6-, and 12-month follow-up. For the PLR &gt; 208.28 group, the patency rates were 80.8%, 71.2%, and 50.7% for the 3-, 6-, and 12-month follow-up, respectively (p = 0.014). The multivariate analysis highlighted that diabetes mellitus, the neutrophil count, the lymphocyte count, and the NLR were independent risk factors for an AVF failure. In our experience, the NLR and PLR are useful markers for the stratification of vascular access failure in hemodialysis patients. The inexpensive nature and ready availability of the values of these biomarkers are two points of strength for everyday clinical practice

    Fabrication of Green Diatomite/Chitosan-Based Hybrid Foams with Dye Sorption Capacity

    Get PDF
    The latest tendency of the scientific community regards the development of different classes of green materials able to solve pollution problems caused by industrial and human activity. In this paper, chitosan and diatomite were used to produce a broad-spectrum hybrid adsorbent, either in powder or in monolithic form for environmental pollutant removal. Diatomite-chitosan-based powders and porous diatomite-chitosan hybrids were prepared and characterized by chemical-physical, thermal and morphological analysis. Moreover, their adsorbent capacity towards anionic dye (Indigo Carmine) was also evaluated. Obtained data showed that chitosan improves the adsorption capacity of both systems, increasing the uptake of dye in both diatomite-chitosan systems.Fil: Galzerano, Barbara. Consiglio Nazionale delle Ricerche; Italia. Università degli Studi di Napoli Federico II; ItaliaFil: Cabello, Carmen Ines. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. Jorge J. Ronco". Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Ciencias Aplicadas; ArgentinaFil: Muñoz, Mercedes. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. Jorge J. Ronco". Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Ciencias Aplicadas; ArgentinaFil: Buonocore, Giovanna G.. Consiglio Nazionale delle Ricerche; ItaliaFil: Aprea, Paolo. Università degli Studi di Napoli Federico II; ItaliaFil: Liguori, Barbara. Consiglio Nazionale delle Ricerche; Italia. Università degli Studi di Napoli Federico II; ItaliaFil: Verdolotti, Letizia. Consiglio Nazionale delle Ricerche; Itali

    Versatile mid-infrared frequency-comb referenced sub-Doppler spectrometer

    Get PDF
    We present a mid-IR high-precision spectrometer capable of performing accurate Doppler-free measurements with absolute calibration of the optical axis and high signal-to-noise ratio. The system is based on a widely tunable mid-IR offset-free frequency comb and a Quantum-Cascade-Laser (QCL). The QCL emission frequency is offset locked to one of the comb teeth to provide absolute-frequency calibration, spectral-narrowing, and accurate fine frequency tuning. Both the comb repetition frequency and QCL-comb offset frequency can be modulated to provide, respectively, slow- and fast-frequency-calibrated scanning capabilities. The characterisation of the spectrometer is demonstrated by recording sub-Doppler saturated absorption features of the CHF3 molecule at around 8.6 μm with a maximum signal-to-noise ratio of ∼7 × 103 in 10 s integration time, frequency-resolution of 160 kHz, and accuracy of less than 10 kHz.We present a mid-IR high-precision spectrometer capable of performing accurate Doppler-free measurements with absolute calibration of the optical axis and high signal-to-noise ratio. The system is based on a widely tunable mid-IR offset-free frequency comb and a Quantum-Cascade-Laser (QCL). The QCL emission frequency is offset locked to one of the comb teeth to provide absolute-frequency calibration, spectral-narrowing, and accurate fine frequency tuning. Both the comb repetition frequency and QCL-comb offset frequency can be modulated to provide, respectively, slow- and fast-frequency-calibrated scanning capabilities. The characterisation of the spectrometer is demonstrated by recording sub-Doppler saturated absorption features of the CHF3 molecule at around 8.6 μm with a maximum signal-to-noise ratio of ∼7 × 103 in 10 s integration time, frequency-resolution of 160 kHz, and accuracy of less than 10 kHz

    frequency metrology in the near infrared spectrum of h217o and h218o molecules testing a new inversion method for retrieval of energy levels

    Get PDF
    An extensive Doppler-free spectroscopic investigation of the near-infrared absorption spectrum of the H218O molecule was performed, for the first time, with absolute frequency calibration by using a GPS-disciplined fiber-based optical frequency comb. The investigated line pairs belong to the ν1+ν3 band and have been chosen in the wavelength range from 1.38 to 1.41μm with a lambda scheme, so as to share the excited energy level and allow an accurate determination of the rotational energy separations of the fundamental vibrational state. The measurement of the sub-Doppler line-center frequencies, also extended to the H217O spectrum, has been performed with an overall uncertainty of ~30 kHz, i.e. about three orders of magnitude lower than the HITRAN data set. The retrieved energy separations agree, by less than 80 kHz, with recent findings provided by the so-called MARVEL procedure for spectral data inversion, thus yielding a very stringent test of its accuracy
    • …