8,694 research outputs found
Measuring Humidity in Sealed Glass Encasements
A technique has been devised for measuring the relative humidity levels in the protective helium/water vapor atmosphere in which the Declaration of Independence, the United States Constitution, and the Bill of Rights are encased behind glass panels on display at the National Archives in Washington, DC. The technique is noninvasive: it does not involve penetrating the encasements (thereby risking contamination or damage to the priceless documents) to acquire samples of the atmosphere. The technique could also be applied to similar glass encasements used to protect and display important documents and other precious objects in museums. The basic principle of the technique is straightforward: An encasement is maintained at its normal display or operating temperature (e.g., room temperature) while a portion of its glass front panel is chilled (see Figure 1) until condensed water droplets become visible on the inside of the panel. The relative humidity of the enclosed atmosphere can then be determined as a known function of the dew point, the temperature below which the droplets condense. Notwithstanding the straightforwardness of the basic principle, careful attention to detail is necessary to enable accurate determination of the dew point. In the initial application, the affected portion of the glass panel was cooled by contact with an aluminum plate that was cooled by a thermoelectric module, the exhaust heat of which was dissipated by a heat sink cooled by a fan. A thermocouple was used to measure the interior temperature of the aluminum plate, and six other thermocouples were used to measure the temperatures at six locations on the cooled outer surface of the glass panel (see Figure 2). Thermal grease was applied to the aluminum plate and the thermocouples to ensure close thermal contact. Power was supplied to the thermoelectric module in small increments, based on previous laboratory tests. A small flashlight and a magnifying glass were used to look for water droplets condensing on the inner surface of the glass. The temperature readings of the thermocouples were taken during cool-down and upon observing condensation. In determining the dew point, it was necessary to make a correction for the differences between the temperatures measured on the chilled outer surface of the glass and the temperature of the inner surface, where the condensation took place. The correction was derived from a laboratory test on a measurement setup that was nearly identical, except that the dew location on the inner surface was also instrumented with a thermocouple. The test showed that the temperature at the dew location on the inner surface of the glass panel was 0.9 C above the temperature determined from the measurements on the chilled outer surface of the panel
Archaeological Testing for a Proposed Landfill Expansion (Phase II) City of Del Rio, Val Verde County, Texas
During September 1989, a pedestrian survey was conducted within a I~S-acre tract acquired by the City of Del Rio, Val Verde County, for a landfill expansion project. The surface reconnaissance recorded one prehistoric site, 41 VV 1251. As a result, recommendation was made for Phase II subsurface testing.
The Phase II subsurface testing, which included a geomorphic study, was accomplished during February 1990. Cultural resources were recovered indicating presence at site 41 VV 1251 from the Late Paleo-Indian period to the Late Archaic period. However, the site was determined to be almost totally deflated. The geomorphological tests verified this assessment and indicated no deeply buried deposits. Site 41 VV 1251 is not deemed potentially eligible for nomination to the National Register of Historic Places or for designation as a State Archeological Landmark
A Portable Infrasonic Detection System
During last couple of years, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Electret-based technology offers the lowest possible background noise, because Johnson noise generated in the supporting electronics (preamplifier) is minimized. The microphone features a high membrane compliance with a large backchamber volume, a prepolarized backplane and a high impedance preamplifier located inside the backchamber. The windscreen, based on the high transmission coefficient of infrasound through matter, is made of a material having a low acoustic impedance and sufficiently thick wall to insure structural stability. Close-cell polyurethane foam has been found to serve the purpose well. In the proposed test, test parameters will be sensitivity, background noise, signal fidelity (harmonic distortion), and temporal stability. The design and results of the compact system, based upon laboratory and field experiments, will be presented
Sub-Surface Windscreen for the Measurement of Outdoor Infrasound
A windscreen has been developed that features two advantages favorable for the measurement of outdoor infrasound. First, the sub-surface location, with the top of the windscreen flush with the ground surface, minimizes the mean velocity of the impinging wind. Secondly, the windscreen material (closed cell polyurethane foam) has a sufficiently low acoustic impedance (222 times that of air) and wall thickness (0.0127 m) to provide a transmission coefficient of nearly unity over the infrasonic frequency range (0-20 Hz). The windscreen, a tightly-sealed box having internal dimensions of 0.3048 x 0.3048 x 0.3556 m, contains a microphone, preamplifier, and a cable feed thru to an external power supply. Provisions are made for rain drainage and seismic isolation. A three-element array, configured as an equilateral triangle with 30.48 m spacing and operating continuously in the field, periodically receives highly coherent signals attributed to emissions from atmospheric turbulence. The time delays between infrasonic signals received at the microphones permit determination of the bearing and elevation of the sources, which correlate well with locations of pilot reports (PIREPS) within a 320 km radius about the array. The test results are interpreted to yield spectral information on infrasonic emissions from clear air turbulence
KINEMATIC PROFILE OF THE ELITE HANDCYCLIST
A handcycle is a relatively new sports equipment that is a combination of the traditional race wheelchair and a hand operated bicycle crank (Abel, Schneider, Platen, & Struder, 2006). The high mechanical efficiency of this geared fixed-frame racing cycle in comparison to a manual wheelchair can potentially increase the distance a person with a loss of lower limb function can travel. To guide the optimal setup for the handcyclist the influence of crank length (Goosey-Tolfrey, Alfano, & Fowler, 2008; Kramer, Hilker, & Bohm, 2009) and crank configuration (Faupin, Gorce, Meyer, & Thevenon, 2008a; Mossberg, Willman, Topor, Crook, & Patak, 1999) have been investigated. Actual neither research has been done on the upper body kinematics of elite athletes nor on relations between kinematics and performance. The aim of this study was to provide first sport specific information in this area with regards to athletes competing at an international level
Collection of Infrasonic Sound From Sources of Military Importance
Extreme Endeavors is collaborating with NASA Langley Research Center (LaRC) in the development, testing and analysis of infrasonic detection system under a Space Act Agreement. Acoustic studies of atmospheric events like convective storms, shear-induced turbulence, acoustic gravity waves, microbursts, hurricanes, and clear air turbulence (CAT) over the past thirty years have established that these events are strong emitters of infrasound. Recently NASA Langley Research Center has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at locations where it was not possible previously, such as a mountain crag, inside a cave or on the battlefield. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Extreme Endeavors will present the findings from field testing using this portable infrasonic detection system. Field testing of the infrasonic detection system was partly funded by Greer Industries and support provided by the West Virginia Division of Natural Resources. The findings from this work illustrate the ability to detect structure and other information about the contents inside the caves. The presentation will describe methodology for utilizing infrasonic to locate and portray underground facilities
Device and method for measuring thermal conductivity of thin films
A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations
The effects of climatic fluctuations and extreme events on running water ecosystems
Most research on the effects of environmental change in freshwaters has focused on incremental changes in average conditions, rather than fluctuations or extreme events such as heatwaves, cold snaps, droughts, floods or wildfires, which may have even more profound consequences. Such events are commonly predicted to increase in frequency, intensity and duration with global climate change, with many systems being exposed to conditions with no recent historical precedent. We propose a mechanistic framework for predicting potential impacts of environmental fluctuations on running water ecosystems by scaling up effects of fluctuations from individuals to entire ecosystems. This framework requires integration of four key components: effects of the environment on individual metabolism, metabolic and biomechanical constraints on fluctuating species interactions, assembly dynamics of local food webs and mapping the dynamics of the meta-community onto ecosystem function. We illustrate the framework by developing a mathematical model of environmental fluctuations on dynamically assembling food webs. We highlight (currently limited) empirical evidence for emerging insights and theoretical predictions. For example, widely supported predictions about the effects of environmental fluctuations are: high vulnerability of species with high per capita metabolic demands such as large-bodied ones at the top of food webs; simplification of food web network structure and impaired energetic transfer efficiency; reduced resilience and top-down relative to bottom-up regulation of food web and ecosystem processes. We conclude by identifying key questions and challenges that need to be addressed to develop more accurate and predictive bio-assessments of the effects of fluctuations, and implications of fluctuations for management practices in an increasingly uncertain world
Quality indicators in the care of older persons in the emergency department: a systematic review of the literature
ObjectiveA systematic review of the literature was undertaken to assess the methodological quality of existing quality indicators (QIs) for the emergency department (ED) care of older persons
Lifetimes in \u3csup\u3e124\u3c/sup\u3eTe: Examining Critical-Point Symmetry in the Te Nuclei
The Doppler-shift attenuation method following inelastic neutron scattering was used to determine the lifetimes of nuclear levels to 3.3-MeV excitation in 124Te. Level energies and spins, γ-ray energies and branching ratios, and multipole-mixing ratios were deduced from measured γ-ray angular distributions at incident neutron energies of 2.40 and 3.30 MeV, γ-ray excitation functions, and γγ coincidence measurements. The newly obtained reduced transition probabilities and level energies for 124Te were compared to critical-point symmetry model predictions. The E(5) and β4 potential critical-point symmetries were also investigated in 122Te and 126Te
- …