9 research outputs found

    Frequency stability measurements of ultra-stable BVA Oscillators

    No full text
    International audienceThe aim of this paper is to present the performances of the instruments developed for the measurement of 5 MHz ultra-stable resonators, before and after being integrated in an oscillator and then measured as an oscillator. The chosen resonator has an estimated stability of several 10-14. Intrinsic noise floor of these benches are about 7 to 8.10-15

    Spectral density of phase noise inter-laboratory comparison final results

    Full text link
    This paper reports main results of the phase noise comparison that has been performed between october 2005 and december 2006, using two oscillators at 5 and 100 MHz and un DRO at 3.5 GHz. The problem is not to compare the performances of several oscillators, but to compare and to make an evaluation of the uncertainties, and of course the resolution and the reproducibility of the measurements. This comparison allow us to determine the ability to get various systems traceable together in order to increase the trust that one can have in phase noise measurements

    Efficient long-range conduction in cable bacteria through nickel protein wires

    Get PDF
    Filamentous cable bacteria display long-range electron transport, generating electrical currents over centimeter distances through a highly ordered network of fibers embedded in their cell envelope. The conductivity of these periplasmic wires is exceptionally high for a biological material, but their chemical structure and underlying electron transport mechanism remain unresolved. Here, we combine high-resolution microscopy, spectroscopy, and chemical imaging on individual cable bacterium filaments to demonstrate that the periplasmic wires consist of a conductive protein core surrounded by an insulating protein shell layer. The core proteins contain a sulfur-ligated nickel cofactor, and conductivity decreases when nickel is oxidized or selectively removed. The involvement of nickel as the active metal in biological conduction is remarkable, and suggests a hitherto unknown form of electron transport that enables efficient conduction in centimeter-long protein structures

    Thermal characterization of crystal ovens used in phase noise measurement system

    No full text
    In this paper, the thermal stability characterization of crystal ovens used in a phase noise measurement system of ultra-low noise crystal resonators is proposed. This bench is dedicated to test 5 MHz and 10 MHz crystal devices packaged in HC40 enclosures. New double ovens have been designed to improve the ultimate noise floor of our carrier suppression bench. A brief description of the temperature environment and processing are given. In addition, experiments to measure the thermal stability of the oven control are given. These new crystal ovens present an Allan standard deviation of about 2â‹…10-15 at 1 s in terms of relative frequency fluctuations

    Phase noise inter-laboratory comparison preliminary results

    No full text
    5 pagesInternational audienceSome phase noise benches used and developed by different research and commercial laboratories have to be tested. The problem is not to compare the performances of several oscillators, but to compare and to make an evaluation of the uncertainties, and of course, to compare the resolution and the reproducibility of the measurements, which are of interest for manufacturers. This comparison allows us to determine the ability to get various systems traceable together in order to increase the trust that one can have in phase noise measurements. Standards to be characterized during this comparison are 5 MHz, 100 MHz and microwave commercial oscillators. Obtained spectra can be affected by the Environmental conditions: temperature, hygrometry, electromagnetic radiations, voltage supplies of oscillators under test and measurement instrumentation, but they also depend on starting conditions of the oscillators and due to their intrinsic nature, and to the time they have been stocked after being switched-off and to the benches themselves. The problem consists in evaluating the possible different contributions. These goals are ambitious, so it is preferable to investigate in priority the inter-laboratory reproducibility in using comparable benches or benches that use equivalent methods, but also measurements resulting from various methods, while we stay in the context of measurements performed in a laboratory. It began in October 2005 and will be finished in april 2006. Preliminary results are now available

    La fièvre catarrhale ovine chez les caprins : données cliniques préliminaires

    No full text
    National audienceLa fièvre catarrhale ovine (FCO) a émergé brutalement en Europe continentale fin 2006. En 2007 et 2008, l’épizootie due au virus BTV-8 a touché une majeure partie du territoire français tandis que le sérotype 1 était responsable dès fin 2007 des premiers foyers dans le sud-ouest. Cet article synthétise les observations cliniques recueillies dans les troupeaux caprins par les vétérinaires, les techniciens et les éleveurs au cours de l’épizootie 2007-2008 en France et dans quelques pays voisins. Ces informations sont convergentes et indiquent une moindre sensibilité de la chèvre en comparaison des ovins, et des bovins, au moins pour le BTV-8 : faible nombre de foyers, faible nombre d’animaux atteints par foyers, gravité modérée et rareté des complications. Les signes cliniques décrits impliquent principalement l’hyperthermie et son cortège de signes associés (abattement, anorexie, chute de production du lait) ainsi qu’une atteinte de la face et des muqueuses buccales. Dans un certain nombre de cas, les infections chroniques associées (parasitisme, paratuberculose..) ont pu aggraver les signes cliniques et les conséquences de l’infection virale. Les données expérimentales, notamment avec le BTV-8, confirment la différence de sensibilité entre caprins et ovins tout en permettant de retrouver les principaux signes cliniques évoquées ci-dessus et confirment aussi la très bonne réceptivité de la chèvre à de nombreux sérotypes de la FCO (virémies pratiquement comparables aux ovins). Les données obtenues pour le BTV-1, plus éparses, sembleraient indiquer un tableau clinique un peu différent. La survenue éventuelle d’autres sérotypes doit conduire à réévaluer la question de la sensibilité de la chèvre laitière à la FCO

    La fièvre catarrhale ovine chez les caprins : données cliniques préliminaires

    No full text
    National audienceLa fièvre catarrhale ovine (FCO) a émergé brutalement en Europe continentale fin 2006. En 2007 et 2008, l’épizootie due au virus BTV-8 a touché une majeure partie du territoire français tandis que le sérotype 1 était responsable dès fin 2007 des premiers foyers dans le sud-ouest. Cet article synthétise les observations cliniques recueillies dans les troupeaux caprins par les vétérinaires, les techniciens et les éleveurs au cours de l’épizootie 2007-2008 en France et dans quelques pays voisins. Ces informations sont convergentes et indiquent une moindre sensibilité de la chèvre en comparaison des ovins, et des bovins, au moins pour le BTV-8 : faible nombre de foyers, faible nombre d’animaux atteints par foyers, gravité modérée et rareté des complications. Les signes cliniques décrits impliquent principalement l’hyperthermie et son cortège de signes associés (abattement, anorexie, chute de production du lait) ainsi qu’une atteinte de la face et des muqueuses buccales. Dans un certain nombre de cas, les infections chroniques associées (parasitisme, paratuberculose..) ont pu aggraver les signes cliniques et les conséquences de l’infection virale. Les données expérimentales, notamment avec le BTV-8, confirment la différence de sensibilité entre caprins et ovins tout en permettant de retrouver les principaux signes cliniques évoquées ci-dessus et confirment aussi la très bonne réceptivité de la chèvre à de nombreux sérotypes de la FCO (virémies pratiquement comparables aux ovins). Les données obtenues pour le BTV-1, plus éparses, sembleraient indiquer un tableau clinique un peu différent. La survenue éventuelle d’autres sérotypes doit conduire à réévaluer la question de la sensibilité de la chèvre laitière à la FCO
    corecore