104 research outputs found

    Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Get PDF
    Amplitude-modulated (AM) laser imaging is a promising technology for the production of accurate three-dimensional (3D) images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise) that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager ( = 405 nm) for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome). The obtained results confirm the validity of the proposed methods for optical noise rejection

    Estimation of mechanical property degradation of poly(lactic acid) and flax fibre reinforced poly(lactic acid) bio-composites during thermal processing

    Get PDF
    Thermal degradation and chemical degradation are among the key issues affecting mechanical properties and ultimately utilization of natural fibre reinforced polymer (NFRP) bio-composites. In our previous work, mathematical models were used to identify thermal processing boundaries and to recognize an optimized window for NFRP bio-composites. In this study, a correlation relating the tensile strength of flax/PLA bio-composite to the processing temperature history is proposed. For the first time, an existing linear model, which corresponds to the tensile strength of natural polymers and their degree of polymerization, has been combined with reaction kinetics to predict the tensile strength of NFRP bio-composites as a function of processing temperature history. In addition, a non-linear model has been proposed which shows a significant improvement for longer periods of time, compared with the linear model. The model is based on the underlying thermo-chemical degradation processes occurring during manufacture of NFRP bio-composites. The model is capable of predicting the tensile strength of the bio-composite within 10% error

    Improving underwater imaging in an amplitude-modulated laser system with radio frequency control technique

    Get PDF
    We present the results of an experiment aimed to demonstrate the low-pass filter dependence of water backscattered power in an amplitude-modulated laser scanner for underwater 3D imaging. We also demonstrate that improvements in target imaging are obtained by allowing the device to operate in the stop-band region. A simple model is described to account for the physics underlying the effect and suggesting future experimental schemes based on demodulated detection techniques

    ACCURATE WAVELENGTH MEASUREMENTS AND MODELING OF Fe XV TO Fe XIX SPECTRA RECORDED IN HIGH-DENSITY PLASMAS BETWEEN 13.5 AND 17 A

    Get PDF
    Iron spectra have been recorded from plasmas created at three different laser plasma facilities: the Tor Vergata University laser in Rome (Italy), the Hercules laser at ENEA in Frascati (Italy), and the Compact Multipulse Terawatt (COMET) laser at LLNL in California (USA). The measurements provide a means of identifying dielectronic satellite lines from Fe XVI and Fe XV in the vicinity of the strong 2p → 3d transitions of Fe XVII. About 80 Δn ≥ 1 lines of Fe XV (Mg-like) to Fe XIX (O-like) were recorded between 13.8 and 17.1 A with a high spectral resolution (λ/Δλ ≈ 4000); about 30 of these lines are from Fe XVI and Fe XV. The laser-produced plasmas had electron temperatures between 100 and 500 eV and electron densities between 1020 and 1022 cm-3. The Hebrew University Lawrence Livermore Atomic Code (HULLAC) was used to calculate the atomic structure and atomic rates for Fe XV-XIX. HULLAC was used to calculate synthetic line intensities at Te = 200 eV and ne = 1021 cm-3 for three different conditions to illustrate the role of opacity: optically thin plasmas with no excitation-autoionization/dielectronic recombination (EA/DR) contributions to the line intensities, optically thin plasmas that included EA/DR contributions to the line intensities, and optically thick plasmas (optical depth ≈200 μm) that included EA/DR contributions to the line intensities. The optically thick simulation best reproduced the recorded spectrum from the Hercules laser. However, some discrepancies between the modeling and the recorded spectra remain

    Utilization of Renewable Biomass and Waste Materials for Production of Environmentally-Friendly, Bio-based Composites

    Get PDF
    The introduction of renewable biomass into a polymer matrix is an option competing with other possibilities, such as energy recovery and/or re-use in the carbonized state, or production of chemicals, such as, in the case of ligno-cellulosic waste, concentrates on the production of simple sugars, then possibly leading to the development of biopolymers. These competitive applications have also some interest and market, however with a considerable energy, water and materials consumption, due also to the not always high yielding. Other possibilities for renewable biomass are therefore being used as fillers to increase mechanical performance of polymers or to allow e.g., the absorption of toxic chemicals. This review concentrates on the use of biomass as close as possible to the “as received” state, therefore avoiding whenever suitable any thermal treatment. More specifically, it focuses on its introduction into the three categories of oil-based (or bio-based replacement) of engineered polymers, into industrial biopolymers, such as poly(lactic acid) (PLA) and self-developed biopolymers, such as thermoplastic starch (TPS)

    Experimental determination of the permeability of engineering textiles: Benchmark II

    Get PDF
    In this second international permeability benchmark, the in-plane permeability values of a carbon fabric were studied by twelve research groups worldwide. One participant also investigated the deformation of the tested carbon fabric. The aim of this work was to obtain comparable results in order to make a step toward standardization of permeability measurements. Unidirectional injections were thus conducted to determine the unsaturated in-plane permeability tensor of the fabric. Procedures used by participants were specified in the guidelines defined for this benchmark. Participants were asked to use the same values for parameters such as fiber volume fraction, injection pressure and fluid viscosity to minimize sources of scatter. The comparison of the results from each participant was encouraging. The scatter between data obtained while respecting the guidelines was below 25%. However, a higher dispersion was observed when some parameters differed from the recommendations of this exercise.The authors are grateful to J.M. Beraud from Hexcel Fabrics for his support that made possible this exercise. The contributions of J.B. Alms, N.C. Correia, S. Advani, E. Ruiz and P.C.T. Goncalves to the preparation of the guidelines document and templates are acknowledged by the participants of this benchmark.Vernet, N.; Ruiz, E.; Advani, S.; Alms, JB.; Aubert, M.; Barburski, M.; Barari, B.... (2014). Experimental determination of the permeability of engineering textiles: Benchmark II. Composites Part A: Applied Science and Manufacturing. 61:172-184. doi:10.1016/j.compositesa.2014.02.010S1721846

    x ray imaging of bio medical samples using laser plasma based x ray sources and lif detector

    Get PDF
    This contribution to ECPD2019 is dedicated to the memory of Anatoly Faenov. During a period of approximately thirteen years 1994–2006, Anatoly and his wife Tatiana Pikuz (simply "Tania" for friends), accepting the frequent invitations of the National Institute for Nuclear Physics (INFN) and of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), cooperated with many Italian research laboratories dedicated to EUV and soft X-ray generation, spread in different towns (L'Aquila, Frascati, Milano, Padova, Pisa, Roma, etc.). In spite of the fact that they could stay in Italy only about one or two months per year, their activity was so intense that more than 50 peer- reviewed publications were generated from their experimental and theoretical work (just considering only the results obtained at L'Aquila and Tor Vergata—Rome Universities and at the ENEA Research Center of Frascati), without mentioning the cultural atmosphere that they stimulated in the field of Science and Humanity. The numerous experimental spectra obtained at ENEA by means of their spherically bent mica spectrometers, together with the corresponding theoretical simulations performed in Moscow, allowed to study the changing role of different excitations mechanisms for various plasma conditions, and to characterize at best the ENEA laser-plasma source for different applications: polychromatic and monochromatic micro-radiography of dried biological samples at 1 keV, soft X-ray contact microscopy (SXCM) of living cells in the water-window spectral region, spectroscopy of hollow atoms, etc. In this memorial paper, the main results of biological samples imaging on lithium fluoride (LiF) detectors, obtained with the ENEA and Tor Vergata University laser-plasma sources, are presented. In particular, the improvement of the micro-radiography and of the SXCM techniques obtained after moving from photoresist detectors and photographic films to lithium fluoride (LiF) detectors are discussed, for both dried and wet biological samples
    corecore