299 research outputs found

    Open Cluster Characterization via Cross-Correlation with Spectral Library

    Get PDF
    We present a characterization method based on spectral cross-correlation to obtain the physical parameters of the controversial stellar aggregate ESO442-SC04. The data used was obtained with GMOS at Gemini-South telescope including 17 stars in the central region of the ob ject and 6 standard-stars. FXCOR was used in an iterative process to obtain self-consistent radial velocities for the standard-stars and averaged radial velocities for the science spectra. Spectral types, effective temperature, suface gravity and metallicities parameters were determined using FXCOR to correlate cluster spectra with ELODIE spectral library and selecting the best correlation matches using the Tonry and Davis Ratio (TDR). Analysis of the results suggests that the stars in ESO442-SC04 are not bound and therefore they do not constitute a physical system.Comment: 4-page paper from IAU symposium 266. Contains 3 eps figures and IAU document class file 'iau.cls

    Ultrathin cellulose ester films: preparation, characterization and protein immobilization

    Get PDF
    In this study cellulose acetate butyrate (CAB) and carboxymehtylcellulose acetate butyrate (CMCAB) films adsorbed onto silicon wafers were characterized by means of ellipsometry, atomic force microscopy (AFM), sum frequency generation spectroscopy (SFG) and contact angle measurements. The adsorption behavior of lysozyme (LIS) or bovine serum albumin (BSA) onto CAB and CMCAB films was investigated. The amounts of adsorbed LIS or BSA onto CMCAB films were more pronounced than those onto CAB films due to the presence of carboxymethyl group in the CMCAB structure. Besides, the adsorption of BSA molecules on CMCAB films was more favored than that of LIS molecules. Antimicrobial effect of LIS bound to CAB or CMCAB layers was evaluated using Micrococcus luteus as substrate.FAPESPCNPqCoordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES

    Low-aberration beamline optics for synchrotron infrared nanospectroscopy

    Get PDF
    MCTIC - MINISTÉRIO DA CIÊNCIA, TECNOLOGIA, INOVAÇÕES E COMUNICAÇÕESSynchrotron infrared nanospectroscopy is a recently developed technique that enables new possibilities in the broadband chemical analysis of materials in the nanoscale, far beyond the diffraction limit in this frequency domain. Synchrotron infrared ports have exploited mainly the high brightness advantage provided by electron storage rings across the whole infrared range. However, optical aberrations in the beam produced by the source depth of bending magnet emission at large angles prevent infrared nanospectroscopy to reach its maximum capability. In this work we present a low-aberration optical layout specially designed and constructed for a dedicated synchrotron infrared nanospectroscopy beamline. We report excellent agreement between simulated beam profiles (from standard wave propagation and raytracing optics simulations) with experimental measurements. We report an important improvement in the infrared nanospectroscopy experiment related to the improved beamline optics. Finally, we demonstrate the performance of the nanospectroscopy endstation by measuring a hyperspectral image of a polar material and we evaluate the setup sensitivity by measuring ultra-thin polymer films down to 6 nm thick.2691123811249MCTIC - MINISTÉRIO DA CIÊNCIA, TECNOLOGIA, INOVAÇÕES E COMUNICAÇÕESMCTIC - MINISTÉRIO DA CIÊNCIA, TECNOLOGIA, INOVAÇÕES E COMUNICAÇÕE

    Structural aspects of polyanion and hydrophobically modified polycation multilayers on hydrophilic or hydrophobic surfaces

    Get PDF
    Multilayer films of carboxymethylcellulose (CMC), a polyanion, and bromide salts of poly(4-vinylpyridine) quaternized with linear aliphatic chains of 2 (ethyl) and 5 (pentyl) carbon atoms, coded as QPVP-C2 and QPVP-C5, respectively, were fabricated by layer-by-layer (LbL) self-assembly onto Si/SiO2 wafers (hydrophilic substrate) or polystyrene, PS, films (hydrophobic substrate). The films were characterized by means of ex situ and in situ ellipsometry, atomic force microscopy (AFM), contact angle measurements and sum frequency generation vibrational spectroscopy (SFG). Antimicrobial tests were used to assess the exposure of pyridinium moieties to the aqueous medium. In situ ellipsometry indicated that for Si/SiO2 the chains were more expanded than the PS films and both substrates systems composed of QPVP-C5 were thicker than those with QPVP-C2. For dried layers, the alkyl side group size had a small effect on the thickness evolution, regardless of the substrate. At pH 2 the multilayers showed high resistance, evidencing that the build-up is driven not only by cooperative polymer-polymer ion pairing, but also by hydrophobic interactions between the alkyl side chains. The LbL films became irregular as the number of depositions increased. After the last deposition, the wettability of QPVP-C2 or QPVP-C5 terminated systems on the Si/SiO2 wafers and PS films were similar, except for QPVP-C2 on Si/SiO2 wafers. Unlike the morphology observed for LbL films on Si/SiO2 wafers, PS induced the formation of porous structures. SFG showed that in air the molecular orientation of pyridinium groups in multilayers with QPVP-C5 was stronger than in those containing QPVP-C2. The exposure of pyridinium moieties to the aqueous medium was more pronounced when the LbL were assembled on Si/SiO2 wafers.Proyecto Fondecyt (Chile) [1100240]Proyecto Fondecyt (Chile)FAPESP (Brazil) [2010/51219-4, 2007/07263-6]FAPESP (Brazil)CNPq (Brazil)CNPq (Brazil)Rede Nanobiotecnologia CAPESRede Nanobiotecnologia CAPE

    Applying the Maternal Near Miss Approach for the Evaluation of Quality of Obstetric Care: A Worked Example from a Multicenter Surveillance Study

    Get PDF
    Objective. To assess quality of care of women with severe maternal morbidity and to identify associated factors. Method. This is a national multicenter cross-sectional study performing surveillance for severe maternal morbidity, using the World Health Organization criteria. the expected number of maternal deaths was calculated with the maternal severity index (MSI) based on the severity of complication, and the standardized mortality ratio (SMR) for each center was estimated. Analyses on the adequacy of care were performed. Results. 17 hospitals were classified as providing adequate and 10 as nonadequate care. Besides almost twofold increase in maternal mortality ratio, the main factors associated with nonadequate performance were geographic difficulty in accessing health services (P < 0.001), delays related to quality of medical care (P = 0.012), absence of blood derivatives (P = 0.013), difficulties of communication between health services (P = 0.004), and any delay during the whole process (P = 0.039). Conclusions. This is an example of how evaluation of the performance of health services is possible, using a benchmarking tool specific to Obstetrics. in this study the MSI was a useful tool for identifying differences in maternal mortality ratios and factors associated with nonadequate performance of care.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Univ Campinas UNICAMP, Sch Med Sci, Dept Obstet & Gynaecol, BR-13083881 Campinas, SP, BrazilCtr Res Reprod Hlth Campinas Cemicamp, BR-13083888 Campinas, SP, BrazilUniv Fed Amazonas, Manaus, Amazonas, BrazilSch Med Sci, CISAM, Recife, PE, BrazilUniv Fed Ceara, Fortaleza, Ceara, BrazilUniv Fed Bahia, Salvador, BA, BrazilHosp Geral Cesar Cals, Fortaleza, Ceara, BrazilHosp Geral Fortaleza, Fortaleza, Ceara, BrazilMaternidade Odete Valadares, Belo Horizonte, MG, BrazilHosp Materno Infantil, Goiania, Go, BrazilInst Materno Infantil Pernambuco, Recife, PE, BrazilUniv Fed Pernambuco, Recife, PE, BrazilUniv Fed Campina Grande, Campina Grande, PB, BrazilUniv Fed Maranhao, Sao Luis, MA, BrazilUniv Fed Parana, BR-80060000 Curitiba, Parana, BrazilUniv Fed Paraiba, BR-58059900 Joao Pessoa, Paraiba, BrazilHosp Maternidade Fernando Magalhaes, Rio de Janeiro, RJ, BrazilUniv Fed Rio Grande do Sul, Porto Alegre, RS, BrazilHosp Maternidade Celso Pierro, Campinas, SP, BrazilInst Fernandes Figueira Fiocruz, Rio de Janeiro, RJ, BrazilHosp Israelita Albert Einstein, São Paulo, BrazilUniv State São Paulo, Botucatu, SP, BrazilJundiai Sch Med, Jundiai, SP, BrazilUniv São Paulo, BR-14049 Ribeirao Preto, SP, BrazilSanta Casa Limeira, Limeira, SP, BrazilSanta Casa Sao Carlos, Sao Carlos, SP, BrazilMaternidade Leonor Mendes de Barros, São Paulo, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilCNPq: 402702/2008-5Web of Scienc
    • …
    corecore