410 research outputs found

    Chiral probe development for circularly polarised luminescence: comparative study of structural factors determining the degree of induced CPL with four heptacoordinate europium(III) complexes

    Get PDF
    A series of bright, europium(III) complexes has been prepared based on an achiral heptadentate triazacyclononane ligand bearing two strongly absorbing, coordinated aralkynyl pyridyl moieties. The binding of chiral carboxylates, including α-hydroxy acids such as lactate and mandelate, has been monitored by emission spectroscopy and is signalled by the switching on of strong circularly polarised emission. In each case, an R-chiral carboxylate gave rise to emission typical of a Δ complex, most clearly shown in the form of the ΔJ = 4 transition manifold around 700 nm. Variations in the sign and magnitude of the CPL allow the enantiomeric purity and absolute configuration of the acid to be assessed in a sample. Analysis of the relative energies of the parent aqua complexes and their stereoisomeric adducts has been aided by lifetime measurements and density functional theory calculations

    Treating the overlooked majority: quantitative outcomes from an NHS adaptation of Interpersonal Group Psychotherapy for binge eating disorder

    Get PDF
    Purpose: To evaluate the effectiveness of an adaptation of Interpersonal Group Psychotherapy (IPT-G), in facilitating short- and longer-term improvements in eating disorder symptomology, psychosocial impairment, anxiety, depression and attachment difficulties among adults living with overweight and diagnosed with binge eating disorder (BED). Design/methodology/approach: In total, 24 participants completed measures at the start of IPT-G, mid-treatment, discharge and six-month follow-up. Quantitative outcomes were analysed utilising one-way repeated measures analysis of variance. Findings: Treatment retention was 100%. Significant improvements in binge-eating frequency, psychosocial impairment and depression were achieved at mid-treatment and maintained at post-treatment and six-month follow-up, and with large effect sizes. Attachment anxiety had reduced significantly at post-treatment and was maintained at six-month review. Body mass index (BMI) had stabilised by mid-treatment and was maintained at post-treatment and six-month follow-up. All hypotheses were supported, with the exception that attachment avoidance did not improve significantly and following a post-treatment reduction, anxiety symptoms deteriorated slightly by six-month follow-up, such that they were no longer significantly different from pre-treatment levels. Practical implications: Despite being the most prevalent of the eating disorders (compared to anorexia nervosa and bulimia nervosa), BED is under-recognised and under-treated in clinical settings. Results indicate the sustained effectiveness of IPT-G in improving eating disorder and comorbid symptomology associated with BED. Originality/value: This is the first UK study to investigate the effectiveness of IPT-G at treating BED. Unlike previous studies in the field, this study did not exclude participants based on age, BMI or psychiatric comorbidity

    Evidence for a three-nucleon-force effect in proton-deuteron elastic scattering

    Get PDF
    Developments in spin-polarized internal targets for storage rings have permitted measurements of 197 MeV polarized protons scattering from vector polarized deuterons. This work presents measurements of the polarization observables A_y, iT_11, and C_y,y in proton-deuteron elastic scattering. When compared to calculations with and without three-nucleon forces, the measurements indicate that three-nucleon forces make a significant contribution to the observables. This work indicates that three-body forces derived from static nuclear properties appear to be crucial to the description of dynamical properties.Comment: 8 pages 2 figures Latex, submitted to Phys. Rev. Letter

    Anomalous diffusion and the first passage time problem

    Full text link
    We study the distribution of first passage time (FPT) in Levy type of anomalous diffusion. Using recently formulated fractional Fokker-Planck equation we obtain three results. (1) We derive an explicit expression for the FPT distribution in terms of Fox or H-functions when the diffusion has zero drift. (2) For the nonzero drift case we obtain an analytical expression for the Laplace transform of the FPT distribution. (3) We express the FPT distribution in terms of a power series for the case of two absorbing barriers. The known results for ordinary diffusion (Brownian motion) are obtained as special cases of our more general results.Comment: 25 pages, 4 figure

    The Drift Directional Dark Matter Experiments

    Get PDF
    The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector

    Spin-dependent limits from the DRIFT-IId directional dark matter detector

    Get PDF
    Data are presented from the DRIFT-IId detector operated in the Boulby Underground Science Facility in England. A 0.8 m 3 fiducial volume, containing partial pressures of 30 Torr CS 2 and 10 Torr CF 4, was exposed for a duration of 47.4 live-time days with sufficient passive shielding to provide a neutron free environment within the detector. The nuclear recoil events seen are consistent with a remaining low-level background from the decay of radon daughters attached to the central cathode of the detector. However, charge from such events must drift across the entire width of the detector, and thus display large diffusion upon reaching the readout planes of the device. Exploiting this feature, it is shown to be possible to reject energy depositions from these Radon Progeny Recoil events while still retaining sensitivity to fiducial-volume nuclear recoil events. The response of the detector is then interpreted, using the F nuclei content of the gas, in terms of sensitivity to proton spin-dependent WIMP-nucleon interactions, displaying a minimum in sensitivity cross section at 1.8 pb for a WIMP mass of 100 GeV/c 2. This sensitivity was achieved without compromising the direction sensitivity of DRIFT. © 2011 Elsevier B.V. All rights reserved

    Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation

    Get PDF
    Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~ 100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 m3 DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~ 10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBql−1 with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials

    Reducing DRIFT backgrounds with a submicron aluminized-mylar cathode

    Get PDF
    Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a View the MathML source thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within 10%. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of 3.3±0.1 ppt 234U and 73±2 ppb 238U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of 70±20 compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation
    corecore