12 research outputs found

    Changes in the Management of Patients having Radical Radiotherapy for Lung Cancer during the First Wave of the COVID-19 Pandemic in the UK.

    Get PDF
    AIMS: In response to the COVID-19 pandemic, guidelines on reduced fractionation for patients treated with curative-intent radiotherapy were published, aimed at reducing the number of hospital attendances and potential exposure of vulnerable patients to minimise the risk of COVID-19 infection. We describe the changes that took place in the management of patients with stage I-III lung cancer from April to October 2020. MATERIALS AND METHODS: Lung Radiotherapy during the COVID-19 Pandemic (COVID-RT Lung) is a prospective multicentre UK cohort study. The inclusion criteria were: patients with stage I-III lung cancer referred for and/or treated with radical radiotherapy between 2nd April and 2nd October 2020. Patients who had had a change in their management and those who continued with standard management were included. Data on demographics, COVID-19 diagnosis, diagnostic work-up, radiotherapy and systemic treatment were collected and reported as counts and percentages. Patient characteristics associated with a change in treatment were analysed using multivariable binary logistic regression. RESULTS: In total, 1553 patients were included (median age 72 years, 49% female); 93 (12%) had a change to their diagnostic investigation and 528 (34%) had a change to their treatment from their centre's standard of care as a result of the COVID-19 pandemic. Age ≥70 years, male gender and stage III disease were associated with a change in treatment on multivariable analysis. Patients who had their treatment changed had a median of 15 fractions of radiotherapy compared with a median of 20 fractions in those who did not have their treatment changed. Low rates of COVID-19 infection were seen during or after radiotherapy, with only 21 patients (1.4%) developing the disease. CONCLUSIONS: The COVID-19 pandemic resulted in changes to patient treatment in line with national recommendations. The main change was an increase in hypofractionation. Further work is ongoing to analyse the impact of these changes on patient outcomes

    Incorporating radiomics into clinical trials: expert consensus on considerations for data-driven compared to biologically-driven quantitative biomarkers

    Get PDF
    Existing Quantitative Imaging Biomarkers (QIBs) are associated with known biological tissue characteristics and follow a well-understood path of technical, biological and clinical validation before incorporation into clinical trials. In radiomics, novel data-driven processes extract numerous visually imperceptible statistical features from the imaging data with no a priori assumptions on their correlation with biological processes. The selection of relevant features (radiomic signature) and incorporation into clinical trials therefore requires additional considerations to ensure meaningful imaging endpoints. Also, the number of radiomic features tested means that power calculations would result in sample sizes impossible to achieve within clinical trials. This article examines how the process of standardising and validating data-driven imaging biomarkers differs from those based on biological associations. Radiomic signatures are best developed initially on datasets that represent diversity of acquisition protocols as well as diversity of disease and of normal findings, rather than within clinical trials with standardised and optimised protocols as this would risk the selection of radiomic features being linked to the imaging process rather than the pathology. Normalisation through discretisation and feature harmonisation are essential pre-processing steps. Biological correlation may be performed after the technical and clinical validity of a radiomic signature is established, but is not mandatory. Feature selection may be part of discovery within a radiomics-specific trial or represent exploratory endpoints within an established trial; a previously validated radiomic signature may even be used as a primary/secondary endpoint, particularly if associations are demonstrated with specific biological processes and pathways being targeted within clinical trials

    Radiomics as a personalized medicine tool in lung cancer: Separating the hope from the hype.

    No full text
    Radiomics has become a popular image analysis method in the last few years. Its key hypothesis is that medical images harbor biological, prognostic and predictive information that is not revealed upon visual inspection. In contrast to previous work with a priori defined imaging biomarkers, radiomics instead calculates image features at scale and uses statistical methods to identify those most strongly associated to outcome. This builds on years of research into computer aided diagnosis and pattern recognition. While the potential of radiomics to aid personalized medicine is widely recognized, several technical limitations exist which hinder biomarker translation. Aspects of the radiomic workflow lack repeatability or reproducibility under particular circumstances, which is a key requirement for the translation of imaging biomarkers into clinical practice. One of the most commonly studied uses of radiomics is for personalized medicine applications in Non-Small Cell Lung Cancer (NSCLC). In this review, we summarize reported methodological limitations in CT based radiomic analyses together with suggested solutions. We then evaluate the current NSCLC radiomics literature to assess the risk associated with accepting the published conclusions with respect to these limitations. We review different complementary scoring systems and initiatives that can be used to critically appraise data from radiomics studies. Wider awareness should improve the quality of ongoing and future radiomics studies and advance their potential as clinically relevant biomarkers for personalized medicine in patients with NSCLC

    Reliability and prognostic value of radiomic features are highly dependent on choice of feature extraction platform.

    No full text
    Objective To investigate the effects of Image Biomarker Standardisation Initiative (IBSI) compliance, harmonisation of calculation settings and platform version on the statistical reliability of radiomic features and their corresponding ability to predict clinical outcome.Methods The statistical reliability of radiomic features was assessed retrospectively in three clinical datasets (patient numbers: 108 head and neck cancer, 37 small-cell lung cancer, 47 non-small-cell lung cancer). Features were calculated using four platforms (PyRadiomics, LIFEx, CERR and IBEX). PyRadiomics, LIFEx and CERR are IBSI-compliant, whereas IBEX is not. The effects of IBSI compliance, user-defined calculation settings and platform version were assessed by calculating intraclass correlation coefficients and confidence intervals. The influence of platform choice on the relationship between radiomic biomarkers and survival was evaluated using univariable cox regression in the largest dataset.Results The reliability of radiomic features calculated by the different software platforms was only excellent (ICC > 0.9) for 4/17 radiomic features when comparing all four platforms. Reliability improved to ICC > 0.9 for 15/17 radiomic features when analysis was restricted to the three IBSI-compliant platforms. Failure to harmonise calculation settings resulted in poor reliability, even across the IBSI-compliant platforms. Software platform version also had a marked effect on feature reliability in CERR and LIFEx. Features identified as having significant relationship to survival varied between platforms, as did the direction of hazard ratios.Conclusion IBSI compliance, user-defined calculation settings and choice of platform version all influence the statistical reliability and corresponding performance of prognostic models in radiomics.Key points • Reliability of radiomic features varies between feature calculation platforms and with choice of software version. • Image Biomarker Standardisation Initiative (IBSI) compliance improves reliability of radiomic features across platforms, but only when calculation settings are harmonised. • IBSI compliance, user-defined calculation settings and choice of platform version collectively affect the prognostic value of features
    corecore