75 research outputs found

    Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To assess the impact of two multileaf collimator (MLC) systems (2.5 and 5 mm leaf widths) on three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and dynamic conformal arc techniques for stereotactic body radiation therapy (SBRT) of liver and lung lesions.</p> <p>Methods</p> <p>Twenty-nine SBRT plans of primary liver (n = 11) and lung (n = 18) tumors were the basis of this study. Five-millimeter leaf width 120-leaf Varian Millennium (M120) MLC-based plans served as reference, and were designed using static conformal beams (3DCRT), sliding-window intensity-modulated beams (IMRT), or dynamic conformal arcs (DCA). Reference plans were either re-optimized or recomputed, with identical planning parameters, for a 2.5-mm width 120-leaf BrainLAB/Varian high-definition (HD120) MLC system. Dose computation was based on the anisotropic analytical algorithm (AAA, Varian Medical Systems) with tissue heterogeneity taken into account. Each plan was normalized such that 100% of the prescription dose covered 95% of the planning target volume (PTV). Isodose distributions and dose-volume histograms (DVHs) were computed and plans were evaluated with respect to target coverage criteria, normal tissue sparing criteria, as well as treatment efficiency.</p> <p>Results</p> <p>Dosimetric differences achieved using M120 and the HD120 MLC planning were generally small. Dose conformality improved in 51.7%, 62.1% and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. Dose heterogeneity increased in 75.9%, 51.7%, and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. DVH curves demonstrated a decreased volume of normal tissue irradiated to the lower (90%, 50% and 25%) isodose levels with the HD120 MLC.</p> <p>Conclusion</p> <p>Data derived from the present comparative assessment suggest dosimetric merit of the high definition MLC system over the millennium MLC system. However, the clinical significance of these results warrants further investigation in order to determine whether the observed dosimetric advantages translate into outcome improvements.</p

    LINAC based stereotactic radiosurgery for multiple brain metastases: guidance for clinical implementation

    Get PDF
    Introduction: Stereotactic radiosurgery (SRS) is a promising treatment option for patients with multiple brain metastases (BM). Recent technical advances have made LINAC based SRS a patient friendly technique, allowing for accurate patient positioning and a short treatment time. Since SRS is increasingly being used for patients with multiple BM, it remains essential that SRS be performed with the highest achievable quality in order to prevent unnecessary complications such as radionecrosis. The purpo

    Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition

    Get PDF
    BACKGROUND: The RTOG 94-13 trial has provided evidence that patients with high risk prostate cancer benefit from an additional radiotherapy to the pelvic nodes combined with concomitant hormonal ablation. Since lymphatic drainage of the prostate is highly variable, the optimal target volume definition for the pelvic lymph nodes is problematic. To overcome this limitation, we tested the feasibility of an intensity modulated radiation therapy (IMRT) protocol, taking under consideration the individual pelvic sentinel node drainage pattern by SPECT functional imaging. METHODS: Patients with high risk prostate cancer were included. Sentinel nodes (SN) were localised 1.5–3 hours after injection of 250 MBq (99m)Tc-Nanocoll using a double-headed gamma camera with an integrated X-Ray device. All sentinel node localisations were included into the pelvic clinical target volume (CTV). Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvis and 70.0 Gy (5 × 2.0 Gy / week) to the prostate including the base of seminal vesicles or whole seminal vesicles. Patients were treated with IMRT. Furthermore a theoretical comparison between IMRT and a three-dimensional conformal technique was performed. RESULTS: Since 08/2003 6 patients were treated with this protocol. All patients had detectable sentinel lymph nodes (total 29). 4 of 6 patients showed sentinel node localisations (total 10), that would not have been treated adequately with CT-based planning ('geographical miss') only. The most common localisation for a probable geographical miss was the perirectal area. The comparison between dose-volume-histograms of IMRT- and conventional CT-planning demonstrated clear superiority of IMRT when all sentinel lymph nodes were included. IMRT allowed a significantly better sparing of normal tissue and reduced volumes of small bowel, large bowel and rectum irradiated with critical doses. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 (RTOG) occurred. CONCLUSION: IMRT based on sentinel lymph node identification is feasible and reduces the probability of a geographical miss. Furthermore, IMRT allows a pronounced sparing of normal tissue irradiation. Thus, the chosen approach will help to increase the curative potential of radiotherapy in high risk prostate cancer patients

    The putative tumour suppressor protein Latexin is secreted by prostate luminal cells and is downregulated in malignancy

    Get PDF
    Loss of latexin (LXN) expression negatively correlates with the prognosis of several human cancers. Despite association with numerous processes including haematopoietic stem cell (HSC) fate, inflammation and tumour suppression, a clearly defined biological role for LXN is still lacking. Therefore, we sought to understand LXN expression and function in the normal and malignant prostate to assess its potential as a therapeutic target. Our data demonstrate that LXN is highly expressed in normal prostate luminal cells but downregulated in high Gleason grade cancers. LXN protein is both cytosolic and secreted by prostate cells and expression is directly and potently upregulated by all-trans retinoic acid (atRA). Whilst overexpression of LXN in prostate epithelial basal cells did not affect cell fate, LXN overexpression in the luminal cancer line LNCaP reduced plating efficiency. Transcriptome analysis revealed that LXN overexpression had no direct effects on gene expression but had significant indirect effects on important genes involved in both retinoid metabolism and IFN-associated inflammatory responses. These data highlight a potential role for LXN in retinoid signaling and inflammatory pathways. Investigating the effects of LXN on immune cell function in the tumour microenvironment (TME) may reveal how observed intratumoural loss of LXN affects the prognosis of many adenocarcinomas

    Syntactic processing in music and language : effects of interrupting auditory streams with alternating timbres

    No full text
    Music and language both rely on the processing of spectral (pitch, timbre) and temporal (rhythm) information to create structure and meaning from incoming auditory streams. Behavioral results have shown that interrupting a melodic stream with unexpected changes in timbre leads to reduced syntactic processing. Such findings suggest that syntactic processing is conditional on successful streaming of incoming sequential information. The current study used event-related potentials (ERPs) to investigate whether (1) the effect of alternating timbres on syntactic processing is reflected in a reduced brain response to syntactic violations, and (2) the phenomenon is similar for music and language. Participants listened to melodies and sentences with either one timbre (piano or one voice) or three timbres (piano, guitar, and vibraphone, or three different voices). Half the stimuli contained syntactic violations: an out-of-key note in the melodies, and a phrase-structure violation in the sentences. We found smaller ERPs to syntactic violations in music in the three-timbre compared to the one-timbre condition, reflected in a reduced early right anterior negativity (ERAN). A similar but non-significant pattern was observed for language stimuli in both the early left anterior negativity (ELAN) and the left anterior negativity (LAN) ERPs. The results suggest that disruptions to auditory streaming may interfere with syntactic processing, especially for melodic sequences

    Can rhythm-mediated reward boost learning, memory, and social connection? Perspectives for future research

    Get PDF
    International audienceStudies of rhythm processing and of reward have progressed separately, with little connection between the two. However, consistent links between rhythm and reward are beginning to surface, with research suggesting that synchronization to rhythm is rewarding, and that this rewarding element may in turn also boost this synchronization. The current mini review shows that the combined study of rhythm and reward can be beneficial to better understand their independent and combined roles across two central aspects of cognition: 1) learning and memory, and 2) social connection and interpersonal synchronization; which have so far been studied largely independently. From this basis, it is discussed how connections between rhythm and reward can be applied to learning and memory and social connection across different populations, taking into account individual differences, clinical populations, human development, and animal research. Future research will need to consider the rewarding nature of rhythm, and that rhythm can in turn boost reward, potentially enhancing other cognitive and social processes
    • …
    corecore