774 research outputs found

    Precise determination of the structure factor and contact in a unitary Fermi gas

    Get PDF
    We present a high-precision determination of the universal contact parameter in a strongly interacting Fermi gas. In a trapped gas at unitarity we find the contact to be 3.06±0.083.06 \pm 0.08 at a temperature of 0.08 of the Fermi temperature in a harmonic trap. The contact governs the high-momentum (short-range) properties of these systems and this low temperature measurement provides a new benchmark for the zero temperature homogeneous contact. The experimental measurement utilises Bragg spectroscopy to obtain the dynamic and static structure factors of ultracold Fermi gases at high momentum in the unitarity and molecular Bose-Einstein condensate (BEC) regimes. We have also performed quantum Monte Carlo calculations of the static properties, extending from the weakly coupled Bardeen-Cooper-Schrieffer (BCS) regime to the strongly coupled BEC case, which show agreement with experiment at the level of a few percent.Comment: Replaced with accepted versio

    Transcatheter closure of Ventricular Septal defects in Malta : initial experience

    Get PDF
    Ventricular septal defects (VSD) consist of deficiencies of the wall separating the two ventricles. VSDs are the commonest congenital cardiac defects. Small VSDs rarely require intervention, however, larger defects cause ventricular volume overload with or without heart failure or pulmonary hypertension and may, therefore, require closure. Traditionally, closure has been an open heart surgical procedure. In recent years, various devices have been developed to close a wide variety of cardiac defects including atrial septal defects and patent arterial ducts through transcatheter interventional techniques. Recently, AGA Medical Corporation have introduced a range of Amplatzer VSD occluders which include specific devices for perimembranous (PM), muscular and post myocardial infarction (MI) VSDs. Atrial septal defect and patent foramen ovale closure has been carried out at St. Luke's Hospital in Malta for the past three years. This year, for the first time, we have closed three VSDs in three individuals; two children with large perimembranous defects and an elderly gentleman with a large post-MI VSD. This paper will discuss this technique and initial results.peer-reviewe

    Transcatheter device closure of atrial septal defect and patent foramen ovale in Malta

    Get PDF
    Significant atrial septal defects (ASD) are closed, surgically or through a transcatheter device, in order to avoid pulmonary hypertension in late life. A patent foramen ovale (PFO) may need to be closed because of transient shunt reversal resulting in transient ischaemic events or stroke. We report the Maltese experience to date in transcatheter closure of these defects. A total of 46 ASDs and 51 PFOs have been successfully closed at our unit (total 97), with very low complication rates, rates that compare very favourably with results from larger international centres.peer-reviewe

    Incidence of congenital pyloric stenosis in Malta

    Get PDF
    The first operation for congenital pyloric stenosis in Malta was carried out in 1949. Up to that time it was thought that this disease did not exist locally. However, an increasing number of cases have been diagnosed since then: presumably this is due to more accurate diagnosis and to the fact that doctors have become more aware of its existence. The purpose of this paper is to review the incidence of congenital pyloric stenosis in Malta as well as to compare this incidence to that of other countries.peer-reviewe

    SKA studies of nearby galaxies : star-formation, accretion processes and molecular gas across all environments

    Get PDF
    Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike LicenceThe SKA will be a transformational instrument in the study of our local Universe. In particular, by virtue of its high sensitivity (both to point sources and diffuse low surface brightness emission), angular resolution and the frequency ranges covered, the SKA will undertake a very wide range of astrophysical research in the field of nearby galaxies. By surveying vast numbers of nearby galaxies of all types with μ\muJy sensitivity and sub-arcsecond angular resolutions at radio wavelengths, the SKA will provide the cornerstone of our understanding of star-formation and accretion activity in the local Universe. In this chapter we outline the key continuum and molecular line science areas where the SKA, both during phase-1 and when it becomes the full SKA, will have a significant scientific impact.Peer reviewedFinal Published versio

    Automation and validation of micronucleus detection in the 3D EpiDerm™ human reconstructed skin assay and correl

    Get PDF
    Recent restrictions on the testing of cosmetic ingredients in animals have resulted in the need to test the genotoxic potential of chemicals exclusively in vitro prior to licensing. However, as current in vitro tests produce some misleading positive results, sole reliance on such tests could prevent some chemicals with safe or beneficial exposure levels from being marketed. The 3D human reconstructed skin micronucleus (RSMN) assay is a promising new in vitro approach designed to assess genotoxicity of dermally applied compounds. The assay utilises a highly differentiated in vitro model of the human epidermis. For the first time, we have applied automated micronucleus detection to this assay using MetaSystems Metafer Slide Scanning Platform (Metafer), demonstrating concordance with manual scoring. The RSMN assay's fixation protocol was found to be compatible with the Metafer, providing a considerably shorter alternative to the recommended Metafer protocol. Lowest observed genotoxic effect levels (LOGELs) were observed for mitomycin-C at 4.8 μg/ ml and methyl methanesulfonate (MMS) at 1750 μg/ml when applied topically to the skin surface. In-medium dosing with MMS produced a LOGEL of 20 μg/ml, which was very similar to the topical LOGEL when considering the total mass of MMS added. Comparisons between 3D medium and 2D LOGELs resulted in a 7-fold difference in total mass of MMS applied to each system, suggesting a protective function of the 3D microarchitecture. Interestingly, hydrogen peroxide (H2O 2), a positive clastogen in 2D systems, tested negative in this assay. A non-genotoxic carcinogen, methyl carbamate, produced negative results, as expected. We also demonstrated expression of the DNA repair protein N-methylpurine-DNA glycosylase in EpiDerm™. Our preliminary validation here demonstrates that the RSMN assay may be a valuable followup to the current in vitro test battery, and together with its automation, could contribute to minimising unnecessary in vivo tests by reducing in vitro misleading positives. © The Author 2014

    An assessment of different extraction and quantification methods of penta- and hexa-chlorobenzene from SRF fly-ash

    Get PDF
    Highly chlorinated benzenes, produced in the presence of organic matter and chlorine, are considered PCDD/Fs precursors, and are used as cost and time convenient substitute indicators for the indirect measurement of the latter. In this study penta- and hexa-chlorobenzene are quantified for the determination of the organochloride load of fly ash from solid recovered fuel incineration. Some of the chlorobenzenes are formed under ‘de novo’ conditions, through heterogeneous (ash particles/flue gases) reactions and are therefore deeply incorporated within fly ash. Accelerated solvent extraction (ASE) and ultrasonic solvent extraction (USE), along with the equivalent clean-up methods suggested by literature were compared to traditional Soxhlet. The extraction efficiencies achieved were 83 ± 7.5% for Soxhlet, 111 ± 19% for PFE, and 67 ± 17% for ultrasonication. Soxhlet extraction and clean-up through a multilayer silica gel column gave more precise results compared to the other sample preparation methods. Furthermore, performance comparison of gas chromatography fitted with either a mass spectrometer operated in single ion monitoring mode (GC-MS-SIM), or electron capture detector (GC- ECD) highlighted that ECD can be used for measuring chlorobenzenes traces down to 0.21 ng g−1, when the equivalent LOQ for MS-SIM was 3.26 ng g−1. The results further suggest that ECD can provide better peak integration than MS-SIM in the detection of chlorobenzenes in fly ash extracts, due to the detector's sensitivity to halogenated compounds
    corecore