8 research outputs found
Spatially resolved GHz magnetization dynamics of a magnetite nano-particle chain inside a magnetotactic bacterium
Magnetic anisotropy of single-crystal antiperovskite Mn3GaC studied by ferromagnetic resonance and dynamic magnetic-response simulations
The combination of micro-resonators with spatially resolved ferromagnetic resonance
We present two new and complementary approaches to realize spatial resolution for ferromagnetic resonance (FMR) on the 100 nm-scale. Both experimental setups utilize lithographically fabricated micro-resonators. They offer a detection sensitivity that is increased by four orders of magnitude compared with resonator-based FMR. In the first setup, the magnetic properties are thermally modulated via the thermal near-field effect generated by the thermal probe of an atomic force microscope. In combination with lock-in detection of the absorbed microwave power in the micro-resonator, a spatial resolution of less than 100 nm is achieved. The second setup is a combination of a micro-resonator with a scanning transmission x-ray microscope (STXM). Here a conventional FMR is excited by the micro-resonator while focused x-rays are used for a time-resolved snap-shot detection of the FMR excitations via the x-ray magnetic circular dichroism effect. This technique allows a lateral resolution of nominally 35 nm given by the STXM. Both experimental setups combine the advantage of low-power FMR excitation in the linear regime with high spatial resolution to study single and coupled nanomagnets. As proof-of-principle experiments, two perpendicular magnetic micro-stripes (5 μm × 1 μm) were grown and their FMR excitations were investigated using both setups
Recommended from our members
Non-standing spin-waves in confined micrometer-sized ferromagnetic structures under uniform excitation
A non-standing characteristic of directly imaged spin-waves in confined micrometer-sized ultrathin Permalloy (Ni 80 Fe 20) structures is reported along with evidence of the possibility to alter the observed state by modifications to the sample geometry. Using micromagnetic simulations, the presence of the spin-wave modes excited in the Permalloy stripes along with the quasi-uniform modes was observed. The predicted spin-waves were imaged in direct space using time resolved scanning transmission X-ray microscopy, combined with a ferromagnetic resonance excitation scheme (STXM-FMR). STXM-FMR measurements revealed a non-standing characteristic of the spin-waves. Also, it was shown by micromagnetic simulations and confirmed using STXM-FMR results that the observed characteristic of the spin-waves can be influenced by the local magnetic fields in different sample geometries
Extracting the Dynamic Magnetic Contrast in Time Resolved X ray Transmission Microscopy
Using a time-resolved detection scheme in scanning transmission X-ray
microscopy (STXM) we measured element resolved ferromagnetic resonance (FMR) at
microwave frequencies up to 10\,GHz and a spatial resolution down to 20\,nm at
two different synchrotrons. We present different methods to separate the
contribution of the background from the dynamic magnetic contrast based on the
X-ray magnetic circular dichroism (XMCD) effect. The relative phase between the
GHz microwave excitation and the X-ray pulses generated by the synchrotron, as
well as the opening angle of the precession at FMR can be quantified. A
detailed analysis for homogeneous and inhomogeneous magnetic excitations
demonstrates that the dynamic contrast indeed behaves as the usual XMCD effect.
The dynamic magnetic contrast in time-resolved STXM has the potential be a
powerful tool to study the linear and non-linear magnetic excitations in
magnetic micro- and nano-structures with unique spatial-temporal resolution in
combination with element selectivity.Comment: 9 pages, 7 figure
Post-anaesthesia pulmonary complications after use of muscle relaxants (POPULAR): a multicentre, prospective observational study
Background: Results from retrospective studies suggest that use of neuromuscular blocking agents during general anaesthesia might be linked to postoperative pulmonary complications. We therefore aimed to assess whether the use of neuromuscular blocking agents is associated with postoperative pulmonary complications. Methods: We did a multicentre, prospective observational cohort study. Patients were recruited from 211 hospitals in 28 European countries. We included patients (aged ≥18 years) who received general anaesthesia for any in-hospital procedure except cardiac surgery. Patient characteristics, surgical and anaesthetic details, and chart review at discharge were prospectively collected over 2 weeks. Additionally, each patient underwent postoperative physical examination within 3 days of surgery to check for adverse pulmonary events. The study outcome was the incidence of postoperative pulmonary complications from the end of surgery up to postoperative day 28. Logistic regression analyses were adjusted for surgical factors and patients' preoperative physical status, providing adjusted odds ratios (ORadj) and adjusted absolute risk reduction (ARRadj). This study is registered with ClinicalTrials.gov, number NCT01865513. Findings: Between June 16, 2014, and April 29, 2015, data from 22 803 patients were collected. The use of neuromuscular blocking agents was associated with an increased incidence of postoperative pulmonary complications in patients who had undergone general anaesthesia (1658 [7·6%] of 21 694); ORadj 1·86, 95% CI 1·53–2·26; ARRadj −4·4%, 95% CI −5·5 to −3·2). Only 2·3% of high-risk surgical patients and those with adverse respiratory profiles were anaesthetised without neuromuscular blocking agents. The use of neuromuscular monitoring (ORadj 1·31, 95% CI 1·15–1·49; ARRadj −2·6%, 95% CI −3·9 to −1·4) and the administration of reversal agents (1·23, 1·07–1·41; −1·9%, −3·2 to −0·7) were not associated with a decreased risk of postoperative pulmonary complications. Neither the choice of sugammadex instead of neostigmine for reversal (ORadj 1·03, 95% CI 0·85–1·25; ARRadj −0·3%, 95% CI −2·4 to 1·5) nor extubation at a train-of-four ratio of 0·9 or more (1·03, 0·82–1·31; −0·4%, −3·5 to 2·2) was associated with better pulmonary outcomes. Interpretation: We showed that the use of neuromuscular blocking drugs in general anaesthesia is associated with an increased risk of postoperative pulmonary complications. Anaesthetists must balance the potential benefits of neuromuscular blockade against the increased risk of postoperative pulmonary complications. Funding: European Society of Anaesthesiology
Post-anaesthesia pulmonary complications after use of muscle relaxants (POPULAR): a multicentre, prospective observational study
Background Results from retrospective studies suggest that use of neuromuscular blocking agents during general anaesthesia might be linked to postoperative pulmonary complications. We therefore aimed to assess whether the use of neuromuscular blocking agents is associated with postoperative pulmonary complications.Methods We did a multicentre, prospective observational cohort study. Patients were recruited from 211 hospitals in 28 European countries. We included patients (aged >= 18 years) who received general anaesthesia for any in-hospital procedure except cardiac surgery. Patient characteristics, surgical and anaesthetic details, and chart review at discharge were prospectively collected over 2 weeks. Additionally, each patient underwent postoperative physical examination within 3 days of surgery to check for adverse pulmonary events. The study outcome was the incidence of postoperative pulmonary complications from the end of surgery up to postoperative day 28. Logistic regression analyses were adjusted for surgical factors and patients' preoperative physical status, providing adjusted odds ratios (ORadj) and adjusted absolute risk reduction (ARR(adj)). This study is registered with ClinicalTrials. gov, number NCT01865513.Findings Between June 16, 2014, and April 29, 2015, data from 22 803 patients were collected. The use of neuromuscular blocking agents was associated with an increased incidence of postoperative pulmonary complications in patients who had undergone general anaesthesia (1658 [7.6%] of 21 694); ORadj 1.86, 95% CI 1.53-2.26; ARR(adj) -4.4%, 95% CI -5.5 to -3.2). Only 2.3% of high-risk surgical patients and those with adverse respiratory profiles were anaesthetised without neuromuscular blocking agents. The use of neuromuscular monitoring (ORadj 1.31, 95% CI 1.15-1.49; ARR(adj) -2.6%, 95% CI -3.9 to -1.4) and the administration of reversal agents (1.23, 1.07-1.41; -1.9%, -3.2 to -0.7) were not associated with a decreased risk of postoperative pulmonary complications. Neither the choice of sugammadex instead of neostigmine for reversal (ORadj 1.03, 95% CI 0.85-1 center dot 25; ARR(adj) -0.3%, 95% CI -2.4 to 1.5) nor extubation at a train-of-four ratio of 0.9 or more (1.03, 0.82-1.31; -0.4%, -3.5 to 2.2) was associated with better pulmonary outcomes.Interpretation We showed that the use of neuromuscular blocking drugs in general anaesthesia is associated with an increased risk of postoperative pulmonary complications. Anaesthetists must balance the potential benefits of neuromuscular blockade against the increased risk of postoperative pulmonary complications