7 research outputs found

    Radiation dose management in fluoroscopy procedures: less is more?

    Get PDF
    The aims of this study are (1) to determine the scattered radiation dose levels in routine fluoroscopy procedures and (2) to compare them with the equivalent chest x-rays and also (3) to monitor common techniques and radiation safety measures taken by the medical officers. The study covered a sample of 105 fluoroscopic procedures performed by 18 medical officers. Each officer wore a personal pocket dosimeter inside the lead gown during each procedure. A digital dosimeter was placed near the detector of the fluoroscopy unit while a survey meter was positioned at the control panel area to record the dose levels. There were 14 types of examination included in this study. The total number of images captured was found to be the highest in barium swallow examination with 115 images, almost five times higher compared to the common practices. The longest screening time was observed in barium enema examination which is 9.15 seconds. The median of the scattered dose level was the highest in barium meal examination (165.50 μSv) which is equivalent to 8.28 times of average dose impart by chest x-ray examinations. The number of images and the length of screening time depend on the competency levels of the medical officers. They capture as many images as possible to avoid missing any abnormalities, therefore it will always be better if the fluoroscopist is consulted during each case. They should also consistently practice essential protection by minimizing exposure time, maximizing distance from the source tube and utilizing the radiation shielding

    Determination of Aluminium and Physicochemical Parameters in the Palm Oil Estates Water Supply at Johor, Malaysia

    Get PDF
    The study was to determine the concentration of aluminium (Al) and study the physicochemical parameters (pH, total dissolved solids (TDS), turbidity, and residual chlorine) in drinking water supply in selected palm oil estates in Kota Tinggi, Johor. Water samples were collected from the estates with the private and the public water supplies. The sampling points were at the water source (S), the treatment plant outlet (TPO), and at the nearest houses (H1) and the furthest houses (H2) from the TPO. All estates with private water supply failed to meet the NSDWQ for Al with mean concentration of 0.99 ± 1.52 mg/L. However, Al concentrations in all public water supply estates were well within the limit except for one estate. The pH for all samples complied with the NSDWQ except from the private estates for the drinking water supply with an acidic pH (5.50 ± 0.90). The private water supply showed violated turbidity value in the drinking water samples (14.2 ± 24.1 NTU). Insufficient amount of chlorination was observed in the private water supply estates (0.09 ± 0.30 mg/L). Private water supplies with inefficient water treatment served unsatisfactory drinking water quality to the community which may lead to major health problems

    Perceptions on radioprotective garment usage and underlying reasons for non-adherence among medical radiation workers from public hospitals in a middle-income Asian setting: A qualitative exploration

    No full text
    Background: Radioprotective garments protect medical radiation workers from exposure to radiation at workplace. However, previous studies have found poor adherence to the use of radioprotective garments. Objectives: We explored the perceptions and practices related to the use of radioprotective garments among medical radiation workers in public hospitals, and sought to understand the reasons for non-adherence. Design and setting: A qualitative approach was applied by conducting face-to-face in-depth interviews with 18 medical radiation workers from three university hospitals using a semi-structured interview guide. Results: Five themes emerged with respect to perceptions on the use of radioprotective garments: (i) the dilemmas in practising radiation protection, (ii) indication of workers' credibility, (iii) physical appearance of radioprotective garments, (iv) practicality of radioprotective garment use, and (v) impact on workflow. Actual lack of radioprotective garment use was attributed to inadequate number of thyroid shield and other garments, radioprotective garments' unsightly appearance including being dirty and defective, impracticality of using radioprotective garments for some nuclear medicine procedures, disruption of workflow because of workers’ limited movements, attitudes of workers, and organisational influences. Conclusion: Medical radiation workers demonstrated a definitive practice of using radioprotective aprons, but often neglected to use thyroid shields and other garments. Availability and hygiene are reported as the core issues, while unclear guidelines on practical use of radioprotective garments appear to lead to confusion among medical radiation workers. To the best of our knowledge, this is the first qualitative study of its kind from a middle-income Asian setting. © 201
    corecore