    Multi-scale analysis of lung computed tomography images

    Get PDF
    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.Comment: 18 pages, 12 low-resolution figure

    A preemptive polling protocol for applications in wireless LANs

    Get PDF

    Noise reduction and spatial resolution in CT imaging with the ASIR iterative reconstruction algorithm at different doses and contrasts – a phantom study

    Get PDF
    Aims and objectives The aim of this study was to quantitatively assess noise reduction and spatial resolution in computed tomography (CT) imaging with the ASIR (Adaptive Statistical Iterative Reconstruction, GE Healthcare) reconstruction algorithm at different kVp, mAs and contrasts. Methods and materials Acquisitions of the Catphan-504 phantom were performed on a PET/CT scanner (Discovery-710, GE Healthcare). CT images were reconstructed using both filtered back projection (FBP) and ASIR with different percentages of reconstruction (20%, 40%, 60%, 80%, 100%). The image noise was estimated for different values of scanning parameters (i.e. tube-load, kilovoltage, pitch, slice thickness). Then, 3D/2D/1D noise power spectrum was estimated. Also, spatial resolution was assessed by obtaining the modulation transfer function (MTF) for a wide range of scanning parameters values and different contrast objects by the circular Edge Spread Function method (using CTP404 modulus) and the Point Spread Function method (using CTP528 modulus). . Results Image noise decreased (up to 50% as compared to FBP) with increasing the percentage of ASIR reconstruction (behaviour more relevant for higher spatial frequencies). Only for low tube load (<56 mAs) and low contrast objects (polistirene with respect to PMMA) acquisitions, MTF analysis showed that ASIR-reconstructed images were characterized by an appreciable reduction in spatial resolution, when compared to FBP-reconstructed images. Conclusion When compared to FBP, ASIR allows a relevant noise reduction without appreciably affecting image quality, except for very low dose and contrast acquisitions

    Automated detection of lung nodules in low-dose computed tomography

    Get PDF
    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (~300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scanComment: 4 pages, 2 figures: Proceedings of the Computer Assisted Radiology and Surgery, 21th International Congress and Exhibition, Berlin, Volume 2, Supplement 1, June 2007, pp 357-35

    Average absorbed breast dose (2ABD): an easy radiation dose index for digital breast tomosynthesis

    Get PDF
    Background: To propose a practical and simple method to individually evaluate the average absorbed dose for digital breast tomosynthesis. Methods: The method is based on the estimate of incident air kerma (ka,i) on the breast surface. An analytical model was developed to calculate the ka,i from the tube voltage, tube load, breast thickness, x-ray tube yield, and anode-filter combination. A homogeneous phantom was employed to simulate the breast in experimental measurements and to assess the dose-depth relationship. The ka,i values were employed to calculate the “average absorbed breast dose” (2ABD) index. Four mammographic units were used to develop and test our method under many conditions close to clinical settings. The average glandular dose (AGD) calculated following the method described by Dance et al., and the 2ABD computed through our method (i.e., from the exposure parameters) were compared in a number of conditions. Results: A good agreement was obtained between the ka,i computed through our model and that measured under different clinical conditions: discrepancies &lt; 6% were found in all conditions. 2ABD matches with a good accuracy the AGD for a 100% glandular-breast: the minimum, maximum, and mean differences were &lt; 0.1%, 7%, and 2.4%, respectively; the discrepancies increase with decreasing breast glandularity. Conclusions: The proposed model, based on only few exposure parameters, represents a simple way to individually calculate an index, 2ABD, which can be interpreted as the average absorbed dose in a homogeneous phantom, approximating a 100% glandular breast. The method could be easily implemented in any mammographic device performing DBT

    Transmission of visual data over wireless fading channel in real-time systems based on superposition coding scheme

    Get PDF
    Real-time visual applications are among the most important requirements in the next generation wireless communication systems. In these applications, the transmitted data comprise different layers with different importance levels based on their influence on the reception quality. Furthermore, the real-time transmission nature of these applications makes them sensitive to data losses and transmission delay. To address these issues, an efficient superposition adaptive modulation and coding system, for the optimal system performance, is proposed in this paper. The proposed system switches its modulation and coding scheme adaptively to select the suitable modulation order and coding rate that best match with the instantaneous channel condition. The channel state information is estimated in receiver and fed back to transmitter. In such method, better performances in both data rate and bit error rate (BER) can be attained. Here, the source data are divided into different priority layers with different importance. Each layer bit stream is sent with specific error protection level against channel corruption. The highest error protection level is assigned to the highest priority layer, and vice versa. The modulated bit streams of all layers are then superimposed together and transmitted via Rayleigh fading channel. At the receiver side, a specific multi-stage decoding receiver is used to reconstruct the source data which demodulates the layers in the order of their priorities. Simulation results show that the proposed system provides up to 18 dB SNR and 46 % data rate gains, respectively, compared to the traditional BPSK scheme at BER of 10−4

    A chiral bis(salicylaldiminato)zinc(ii) complex with second-order nonlinear optical and luminescent properties in solution

    Get PDF
    Whereas there is an increasing amount of reports on the second-order nonlinear optical (NLO) and luminescence properties of tetradentate [N2O2] Schiff base-zinc complexes, the study of zinc complexes having two bidentate [NO] Schiff-base ligands is relatively unexplored from an NLO point of view. This work puts in evidence that the known chiral bis(2-[(R)-(+)-1-phenylethyliminomethyl]phenolato-N, O)zinc(II) complex is a fascinating multifunctional molecular inorganic-organic hybrid material characterized by interesting second-order NLO and luminescent properties in solution. The emissive properties of the organic 2-(R)-(+)-1-phenylethyliminomethyl]phenol proligand are greatly enhanced upon coordination to the inorganic Zn(II) center

    Perylenetetracarboxy-3,4:9,10-diimide derivatives with large two-photon absorption activity

    Get PDF
    Three new perylenetetracarboxy-3,4:9,10-diimides, bearing 2,6-diisopropylphenyl groups at the imide positions and 4-(R-ethynyl)phenoxy moieties (R = 4,7-di(2-thienyl)benzo[c][1,2,5]thiadiazole (P2), pyrene (P3) or pyrene-CH2OCH2 (P4)) at the four bay positions, were prepared, along with the known related derivative (R = phenyl (P1)), and well characterized. They have large two-photon absorption (TPA) cross-sections (sigma(2)), as determined by the Z-scan technique, the highest values being reached with P2 which bears a planar -delocalized donor moiety. P3 is characterized by higher sigma(2) values than both P1, as expected for the higher -conjugation of the donor pyrene moiety with respect to phenyl, and P4, due to the presence of the flexible and non-conjugated CH2OCH2 bridge between the pyrene and the ethynyl fragment in the latter compound. The molecular geometry of P1-P4 has been optimized by DFT modeling, showing that in P2 and P3 the bay substituents are stacked due to the - interactions of both pyrene and thiophene groups. The LUMO of P1-P4 lies at the same energy and is essentially delocalized on the perylene core whereas the HOMO and HOMO-1 of both P2 and P3 are degenerate and do not show contribution from the perylene core contrarily to that of P1 and P4. The HOMO-LUMO gap is therefore essentially influenced by the HOMO which reflects the electronic charge delocalization on the bay substituents, the lower gaps being observed for P2 and P3, which are characterized by the best TPA properties

    Dental radiology dosimetric data as routinely collected in an Italian hospital

    Get PDF
    The work presented here was developed in the framework of the SENTINEL Project and is devoted to the analysis of dental radiology dosimetric data. The procedure of data processing allows the analysis of some important aspects related to the protection of the patient and the staff because of the position of the operators near the patient and their exposure to the radiation scattered by the patient. Dental radiology data was collected in an Italian hospital. Following the Italian quality assurance (QA) protocols and suggestions by the leaders of the SENTINEL Project, X-ray equipment performances have been analysed in terms of: kVp accuracy, exposure time accuracy and precision, tube output, dose reproducibility and linearity, beam collimation, artefacts and light tightness. Referring to these parameters the physical quality index (QI) was analysed. In a single numerical value between 0 and 1, QI summarises the results of quality tests for radiological devices. The actual impact of such a figure (as suggested by international QA protocols or as adopted by local QA routine) on the policy of machine maintenance and replacement is discussed