34 research outputs found

    The effective factors on place attachment in residential environments

    Get PDF
    ABSTRACTBACKGROUND AND OBJECTIVES: Place attachment is among the most important aspects of the interaction between people and their places, to keep residential environments safe, sustained, and resilient. This study aims to identify the factors that influence the creation and enhancement of place attachment in residential settings, with a focus on physical elements. Given the significance of these factors in architecture and facility programming, the study aims to provide architects and designers with effective strategies for designing and redesigning residential environments. The results of this study on place attachment can be utilized in the architectural facility programming process and design decision-making. METHODS: This study proposed a theoretical framework in which the relationship between subjective and objective physical and individual characteristics and time were the main components of making sense of place attachment. Using a survey method, the study investigated the significance of place attachment among residents of the 600-unit residential complex in Mashhad, Iran, through a questionnaire divided into three sections. The first section focused on individual characteristics and time spent in the complex, while the second and third sections measured the objective and subjective physical characteristics and the extent of people's attachment to the complex, respectively. The data from 158 participants were analyzed using SPSS and SmartPLS software.FINDINGS: Results of SPSS analysis showed objective physical characteristics (p<.01, r=.241), as well as the subjective physical characteristics (p<.01, r=.223) and time (p<.01, r=.237), were the most important components affecting place attachment, highlighting the role of physical strategies used in the residential complex for creating and developing this feeling. Considering these physical factors affecting the establishment and enhancement of place attachment emphasizes the role of architects and planners in satisfying this crucial human need which directly affects people's personal and social health.CONCLUSION: The results revealed time, subjective, and objective physical characteristics are three factors that have a direct impact on place attachment. Objective physical characteristics have a direct impact on place attachment and also indirectly impact it through their effect on subjective physical characteristics. On the other hand, the relationship between individual characteristics and place attachment is indirect, as individual characteristics affect the time spent in a place, and an increase in time spent leads to a stronger place attachment. The findings can be employed extensively in architectural programming in residential environments to improve the quality of life

    Evaluation of nanocarrier targeted drug delivery of capecitabine-PAMAM dendrimer complex in a mice colorectal cancer model

    Get PDF
    Capecitabine, an effective anticancer drug in colorectal cancer chemotherapy, may create adverse side effects on healthy tissues. In the present study, we first induced colon adenocarcinoma with azoxymethane, a carcinogen agent, and then investigated the potentiality of polyamidoamine (PAMAM) dendrimer to improve capecitabine therapeutic index and decrease its adverse side effects on healthy tissues like liver and bone marrow. Other variables such as nanoparticle concentrations have also been investigated. Drug loading concentration (DLC) and encapsulation efficiency (EE) were calculated for capecitabine/dendrimer complex. Experimental results showed an increase in DLC percentage resulted from elevated capecitabine/dendrimer ratio. Capecitabine/dendrimer complex could reduce tumor size and adverse side effects in comparison with free capecitabine form. © 2016 Tehran University of Medical Sciences. All rights reserved

    Characterization, possible sources and health risk assessment of PM2.5-bound Heavy Metals in the most industrial city of Iran

    Get PDF
    Air pollution associated with particulate matters results in different types of disease including allergy, lung destruction, heart failure, and related problems. This study has been designed and performed to examine the concentration of PM2.5-bound heavy metals, risk assessment, possible sources and effect of meteorological parameters on 17 sites of the air of the most industrial city of Iran (Karaj) in 2018-19. For this purpose, four samples were taken from every point of Karaj air over one year using a pump (Leland Legacy (SKC)) with flow rate of 3 L/min on PTFE filter for 24 h. Overall, 68 samples of PM2.5-bound heavy metals were collected. Note that during the sampling, atmospheric parameters including temperature, pressure, humidity, and wind speed were regularly recorded using PHB318 portable device. In examining the chemical composition of these particles, the concentration of metals (Al-Zn- Ar-Cd-Cr-Cu-Fe-Hg-Mn-Ni-Pb) was determined after digestion of the collected samples and through injection into ICP-OEC device. The results indicated that the mean annual concentration of PM2.5 particles range from 21.84 to 72.75 µg/m3. The mean concentration of heavy metals lied within the range of 25.63 to 336.27 ng/m3. Among heavy metals, the maximum concentration belonged to aluminum (277.95 ng/m3) and iron (336.27 ng/m3), which are known as elements with a ground source (sources such as car fuels, exhaust gases, decorative materials, batteries, indoor smoking, the paint used for painting walls, erosion and corrosion of rubber of cars). Meanwhile, there was a positive relationship between heavy metals and temperature(r: 0.418, p < 0.019), pressure (r: 0.184, p < 0.0.402), as well as wind speed (r: 0.38, p < 0.017), while an inverse relationship was observed with relative humidity (r: -0.219, p < 0.018). The ecological risk of the metals calculated was very notable, with the maximum environmental risk being related to cadmium in children (6.61) and manganese in adults (0.82). The largest HQ in children and adults was associated with Cr. Finally, ILCR values for cadmium in both children (1.19 E-04) and adult (4.81 E-04) groups indicated high risk of developing cancer in humans

    Monitoring of airborne asbestos fibers in an urban ambient air of Mashhad City, Iran: levels, spatial distribution and seasonal variations

    Get PDF
    Asbestos, as with other pollutants in the air, has adverse effects on the health of human beings and animals. Today, the relationship between presence of asbestos fibers in the air breathed by humans and developing serious diseases such as lung cancer (asbestosis) and mesothelioma has been proven. The objectives of this study were to monitor the levels of asbestos fibers in ambient air of Mashhad, Iran during 2018, and to draw its Geographic Information System (GIS) distribution map for the city. In this descriptive study, 13 sampling points in Mashhad city were chosen. Sampling of asbestos was carried out for 3 hour during summer and winter at 2018. Sampling of asbestos was performed using MCE (Mixed Cellulose Ester) membrane filters (pour size 0.45 µm; diameter: 25 mm) and cassette holder and peripheral pump. The samples were the analyzed by the phase contrast microscopy (PCM) method (NIOSH7400). Also, to investigate the type of asbestos and for more accurate counting of fibers, Scanning Electron Microscopy (SEM) analysis was utilized. Meteorological parameter were recorded through portable devices. To draw the graphs, Excel, R and Arc GIS software were used. Results showed that the mean asbestos fiber concentrations were equal to 11.40 ± 2.14 and 14.38 ± 2.52 f/L in summer and winter, respectively. The maximum level of asbestos fiber was detected in the station of Baitolmoghaddas square by 26.64 ± 2.14 and 19.3 SEM f/L in winter and summer, respectively. High concentration of asbestos fiber observed in this study can be attributed to the heavy traffic, the presence of prominent industries in the vicinity of the study area, and topographic features. The results from this research recommends that suitable controlling policies should be regulated to reduce both ambient air asbestos and its adverse health endpoints in Mashhad. © 2020, Springer Nature Switzerland AG

    Development and implementation of water safety plans for groundwater resources in the southernmost city of West Azerbaijan Province, Iran

    Get PDF
    The transfer of water from the source to the consumption point is always associated with the possibility of contamination in any of its various components. To resolve this problem, the World Health Organization has considered a water safety plan. The purpose of this study is to implement water safety plan in the water supply system of Bukan city. This study was performed on Bukan’s water supply system in 2019–20 using a software to guarantee the quality of the water safety plan and the WHO and IWA guidelines. The software checklists were prepared and after confirming the validity of the translation and its facial and content validity, it was completed based on the records of the Water and Sewerage Company and interviews with experts. Out of a total of 440 points of full-application of the program and 392 points for the reviewed phases, 183.6 points were acquired and 43.7% of WSP-coordinated implementation was observed. The highest percentage of WSP-coordinated implementation (75.2%) was assigned to the validation stage with the highest point, and the support program stage had the lowest percentage of performance (1.1%). Among the major components of the water supply system, the final consumption point received the most attention from the system. Given the lifespan of the introduction and use of WSP in the world, it was expected that better results would be obtained from evaluating the implementation and progress of this approach in Bukan’s water supply system. However, the implementation rate of this program in this city compared to other cities in Iran, showed that according to the implementation time (one year), the obtained results are relatively convincing and good and the water supply system has a moderate level of safety

    Load characteristics and inhalation risk assessment of benzene series (BTEX) pollutant in indoor air of Ghalyan and/ or cigarette cafes compared to smoking-free cafes

    Get PDF
    To determine the concentration of benzene series (BTEX) compounds, 33 samples were collected from indoor air of Ghalyan cafés (GHC), cigarette cafés (CC) and smoking-free cafés (SFC) in Bushehr city, Iran, and analyzed using gas-chromatography - flame ionization detector (GC-FID). The results of this study indicated that the mean±SD values of ΣBTEX in GHC, CC and SFC cafés were 19.46 ± 6.07, 11.34 ± 5.21 and 2.26 ± 0.76 mg/m3, respectively. The mean concentration of BTEX in the cafés with fruit-flavored tobacco was significantly higher than those in traditional cafés (p < 0.05). According to path analysis, the number of active waterpipe heads had the maximum impact on the production of pollutants inside the cafés. The results also indicated that the risk of exposure to BTEX in smoking cafés in Bushehr was very high; it can develop serious carcinogenic and noncarcinogenic risks

    Distinct Regions of the Large Extracellular Domain of Tetraspanin CD9 Are Involved in the Control of Human Multinucleated Giant Cell Formation

    Get PDF
    Multinucleated giant cells, formed by the fusion of monocytes/macrophages, are features of chronic granulomatous inflammation associated with infections or the persistent presence of foreign material. The tetraspanins CD9 and CD81 regulate multinucleated giant cell formation: soluble recombinant proteins corresponding to the large extracellular domain (EC2) of human but not mouse CD9 can inhibit multinucleated giant cell formation, whereas human CD81 EC2 can antagonise this effect. Tetraspanin EC2 are all likely to have a conserved three helix sub-domain and a much less well-conserved or hypervariable sub-domain formed by short helices and interconnecting loops stabilised by two or more disulfide bridges. Using CD9/CD81 EC2 chimeras and point mutants we have mapped the specific regions of the CD9 EC2 involved in multinucleated giant cell formation. These were primarily located in two helices, one in each sub-domain. The cysteine residues involved in the formation of the disulfide bridges in CD9 EC2 were all essential for inhibitory activity but a conserved glycine residue in the tetraspanin-defining ‘CCG’ motif was not. A tyrosine residue in one of the active regions that is not conserved between human and mouse CD9 EC2, predicted to be solvent-exposed, was found to be only peripherally involved in this activity. We have defined two spatially-distinct sites on the CD9 EC2 that are required for inhibitory activity. Agents that target these sites could have therapeutic applications in diseases in which multinucleated giant cells play a pathogenic role

    Concentrations and mortality due to short- and long-term exposure to PM2.5 in a megacity of Iran (2014�2019)

    No full text
    The present study aimed to survey the spatial and temporal trends of ambient concentration of PM2.5 and to estimate mortality attributed to short- and long-term exposure to PM2.5 in Isfahan from March 2014 to March 2019 using the AirQ+ software. The hourly concentrations of PM2.5 were obtained from the Isfahan Department of Environment and Isfahan Air Quality Monitoring Center. Then, the 24-h mean concentration of PM2.5 for each station was calculated using the Excel software. According to the results, the annual mean concentration of PM2.5 in 2014�2019 was 29.9�50.9 μg/m3, approximately 3�5 times higher than the WHO guideline (10 μg/m3). The data showed that people of Isfahan in almost 58 to 96 of the days of a year were exposed to PM2.5 higher than the WHO daily guideline. The concentrations of PM2.5 in cold months such as October, November, December and January were higher than those in the other months. The zoning of the annual concentrations of PM2.5 in urban areas showed that the highest PM2.5 concentrations were related to the northern, northwestern, southern and central areas of the city. On average, from 2014 to 2019, the number of deaths due to natural mortality, lung cancer (LC), chronic obstructive pulmonary disease (COPD), ischemic heart disease (IHD) and stroke associated with ambient PM2.5 were 948, 16, 18, 281 and 60, respectively. The present study estimated that on average, 14.29 of the total mortality, 17.2 of lung cancer (LC), 15.54 of chronic obstructive pulmonary disease (COPD), 17.12 of ischemic heart disease (IHD) and 14.94 of stroke mortalities were related to long-term exposure to ambient PM2.5. So provincial managers and politicians must adopt appropriate strategies to control air pollution and reduce the attributable health effects and economic losses. © 2020, Springer-Verlag GmbH Germany, part of Springer Nature

    The performance of TiO2/NaY-zeolite nanocomposite in photocatalytic degradation of Microcystin-LR from aqueous solutions: Optimization by response surface methodology (RSM)

    No full text
    Background: Microcystin (MC) is a hepatotoxic and carcinogenic toxin that is generated by cyanotoxins which can have adverse effects on the human health. Therefore, it is very important to remove it from the environment. This study was performed to investigate the efficiency of titanium dioxide (TiO2)/NaY-zeolite (T/N-Z) nanocomposite for removal of MC-LR under ultraviolet light. Methods: In the present study, T/N-Z nanocomposite was synthesized using the hydrothermal method. Specification of the photocatalysts was determined by the field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR) spectra. The response surface methodology (RSM) was used to survey the effects of operating variables such as pH, contact time, and catalyst dose on the removal of MC-LR. The MC-LR concentration was measured by high-performance liquid chromatography (HPLC). Results: It was revealed that the increase of contact time and catalyst dose had a positive effect on enhancing the removal efficiency of MC-LR, but pH had a negative effect. Finally, the maximum MC-LR removal efficiency was 97.63, which occurred at pH = 5, contact time = 120 min, and catalyst dose = 1.2 g/L. Conclusion: In general, T/N-Z composite in aqueous solutions under the UV light can easily decompose MC-LR and it can also be proposed as an efficient composite for removal of MC-LR from contaminated water
    corecore