250 research outputs found

    Intravascular Lithotripsy for Treatment of Calcified Coronary Lesions: Patient-Level Pooled Analysis of the Disrupt CAD Studies.

    Get PDF
    Abstract Objectives The aim of this pooled analysis was to assess the cumulative safety and effectiveness of coronary intravascular lithotripsy (IVL). Background The clinical outcomes of IVL to opt..

    The Disrupt CAD II Study

    Get PDF
    BACKGROUND: The feasibility of intravascular lithotripsy (IVL) for modification of severe coronary artery calcification (CAC) was demonstrated in the Disrupt CAD I study (Disrupt Coronary Artery Disease). We next sought to confirm the safety and effectiveness of IVL for these lesions. METHODS: The Disrupt CAD II study was a prospective multicenter, single-arm post-approval study conducted at 15 hospitals in 9 countries. Patients with severe CAC with a clinical indication for revascularization underwent vessel preparation for stent implantation with IVL. The primary end point was in-hospital major adverse cardiac events (cardiac death, myocardial infarction, or target vessel revascularization). An optical coherence tomography substudy was performed to evaluate the mechanism of action of IVL, quantifying CAC characteristics and calcium plaque fracture. Independent core laboratories adjudicated angiography and optical coherence tomography, and an independent clinical events committee adjudicated major adverse cardiac events. RESULTS: Between May 2018 and March 2019, 120 patients were enrolled. Severe CAC was present in 94.2% of lesions. Successful delivery and use of the IVL catheter was achieved in all patients. The post-IVL angiographic acute luminal gain was 0.83±0.47 mm, and residual stenosis was 32.7±10.4%, which further decreased to 7.8±7.1% after drug-eluting stent implantation. The primary end point occurred in 5.8% of patients, consisting of 7 non-Q-wave myocardial infarctions. There was no procedural abrupt closure, slow or no reflow, or perforations. In 47 patients with post-percutaneous coronary intervention optical coherence tomography, calcium fracture was identified in 78.7% of lesions with 3.4±2.6 fractures per lesion, measuring 5.5±5.0 mm in length. CONCLUSIONS: In patients with severe CAC who require coronary revascularization, IVL was safely performed with high procedural success and minimal complications and resulted in substantial calcific plaque fracture in most lesions. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03328949

    A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization

    Get PDF
    BACKGROUND: The need for repeated treatment of restenosis of a treated vessel remains the main limitation of percutaneous coronary revascularization. Because sirolimus (rapamycin) inhibits the proliferation of lymphocytes and smooth-muscle cells, we compared a sirolimus-eluting stent with a standard uncoated stent in patients with angina pectoris. METHODS: We performed a randomized, double-blind trial to compare the two types of stents for revascularization of single, primary lesions in native coronary arteries. The trial included 238 patients at 19 medical centers. The primary end point was in-stent late luminal loss (the difference between the minimal luminal diameter immediately after the procedure and the diameter at six months). Secondary end points included the percentage of in-stent stenosis of the luminal diameter and the rate of restenosis (luminal narrowing of 50 percent or more). We also analyzed a composite clinical end point consisting of death, myocardial infarction, and percutaneous or surgical revascularization at 1, 6, and 12 months. RESULTS: At six months, the degree of neointimal proliferation, manifested as the mean (+/-SD) late luminal loss, was significantly lower in the sirolimus-stent group (-0.01+/-0.33 mm) than in the standard-stent group (0.80+/-0.53 mm, P<0.001). None of the patients in the sirolimus-stent group, as compared with 26.6 percent of those in the standard-stent group, had restenosis of 50 percent or more of the luminal diameter (P<0.001). There were no episodes of stent thrombosis. During a follow-up period of up to one year, the overall rate of major cardiac events was 5.8 percent in the sirolimus-stent group and 28.8 percent in the standard-stent group (P<0.001). The difference was due entirely to a higher rate of revascularization of the target vessel in the standard-stent group. CONCLUSIONS: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events

    Adverse Cardiovascular Events Arising From Atherosclerotic Lesions With and Without Angiographic Disease Progression

    Get PDF
    ObjectivesThe aim of this study was to use angiography and grayscale and intravascular ultrasound–virtual histology to assess coronary lesions that caused events during a median follow-up period of 3.4 years.BackgroundVulnerable plaque-related events are assumed to be the result of substantial progression of insignificant lesions.MethodsIn the PROSPECT (Providing Regional Observations to Study Predictors of Events in the Coronary Tree) study, 697 patients with acute coronary syndromes underwent treatment of all culprit lesions followed by 3-vessel imaging to assess the natural history of culprit and untreated nonculprit (NC) lesions. Future adverse cardiovascular events adjudicated to NC lesions were divided into those with versus without substantial lesion progression (SLP) (≥20% angiographic diameter stenosis increase).ResultsNC lesion events occurred in 72 patients, 44 (61%) with and 28 (39%) without SLP. Myocardial infarctions (n = 6) occurred only in patients with SLP. Conversely, patients without SLP presented only with unstable or increasing angina requiring rehospitalization. Lesions with versus without SLP occurred later (median time to event 401 vs. 223 days, p = 0.07); were less severe at baseline (median diameter stenosis 26.4% vs. 53.8%, p < 0.0001) but more severe at the time of the event (mean diameter stenosis 73.8% vs. 56%, p < 0.0001); and had comparable baseline median plaque burden (68.7% vs. 70.1%, p = 0.17), minimum luminal area (3.7 vs. 4.0 mm2, p = 0.60), and intravascular ultrasound–virtual histology phenotype (83.3% vs. 90.9%, p = 0.68; classified as fibroatheromas at baseline).ConclusionsNC lesions responsible for future cardiovascular events showed angiographic increase during 3.4 years of follow-up, whereas SLP underlay many but not all of them. NC events due to lesions with SLP were angiographically less severe and presented with a delayed time course but were otherwise indistinguishable from NC events that were not associated with SLP

    Reperfusion therapy for ST elevation acute myocardial infarction in Europe: description of the current situation in 30 countries

    Get PDF
    Aims Patient access to reperfusion therapy and the use of primary percutaneous coronary intervention (p-PCI) or thrombolysis (TL) varies considerably between European countries. The aim of this study was to obtain a realistic contemporary picture of how patients with ST elevation myocardial infarction (STEMI) are treated in different European countries. Methods and results The chairpersons of the national working groups/societies of interventional cardiology in European countries and selected experts known to be involved in the national registries joined the writing group upon invitation. Data were collected about the country and any existing national STEMI or PCI registries, about STEMI epidemiology, and treatment in each given country and about PCI and p-PCI centres and procedures in each country. Results from the national and/or regional registries in 30 countries were included in this analysis. The annual incidence of hospital admission for any acute myocardial infarction (AMI) varied between 90–312/100 thousand/year, the incidence of STEMI alone ranging from 44 to 142. Primary PCI was the dominant reperfusion strategy in 16 countries and TL in 8 countries. The use of a p-PCI strategy varied between 5 and 92% (of all STEMI patients) and the use of TL between 0 and 55%. Any reperfusion treatment (p-PCI or TL) was used in 37–93% of STEMI patients. Significantly less reperfusion therapy was used in those countries where TL was the dominant strategy. The number of p-PCI procedures per million per year varied among countries between 20 and 970. The mean population served by a single p-PCI centre varied between 0.3 and 7.4 million inhabitants. In those countries offering p-PCI services to the majority of their STEMI patients, this population varied between 0.3 and 1.1 million per centre. In-hospital mortality of all consecutive STEMI patients varied between 4.2 and 13.5%, for patients treated by TL between 3.5 and 14% and for patients treated by p-PCI between 2.7 and 8%. The time reported from symptom onset to the first medical contact (FMC) varied between 60 and 210 min, FMC-needle time for TL between 30 and 110 min, and FMC-balloon time for p-PCI between 60 and 177 min. Conclusion Most North, West, and Central European countries used p-PCI for the majority of their STEMI patients. The lack of organized p-PCI networks was associated with fewer patients overall receiving some form of reperfusion therapy

    Effects of the high-density lipoprotein mimetic agent CER-001 on coronary atherosclerosis in patients with acute coronary syndromes: a randomized trial†

    Get PDF
    Aim High-density lipoproteins (HDLs) have several potentially protective vascular effects. Most clinical studies of therapies targeting HDL have failed to show benefits vs. placebo. Objective: To investigate the effects of an HDL-mimetic agent on atherosclerosis by intravascular ultrasonography (IVUS) and quantitative coronary angiography (QCA). Design and setting A prospective, double-blinded, randomized trial was conducted at 51 centres in the USA, the Netherlands, Canada, and France. Intravascular ultrasonography and QCA were performed to assess coronary atherosclerosis at baseline and 3 (2–5) weeks after the last study infusion. Patients Five hundred and seven patients were randomized; 417 and 461 had paired IVUS and QCA measurements, respectively. Intervention Patients were randomized to receive 6 weekly infusions of placebo, 3 mg/kg, 6 mg/kg, or 12 mg/kg CER-001. Main outcome measures The primary efficacy parameter was the nominal change in the total atheroma volume. Nominal changes in per cent atheroma volume on IVUS and coronary scores on QCA were also pre-specified endpoints. Results: The nominal change in the total atheroma volume (adjusted means) was −2.71, −3.13, −1.50, and −3.05 mm3 with placebo, CER-001 3 mg/kg, 6 mg/kg, and 12 mg/kg, respectively (primary analysis of 12 mg/kg vs. placebo: P = 0.81). There was also no difference among groups for the nominal change in per cent atheroma volume (0.02, −0.02, 0.01, and 0.19%; nominal P = 0.53 for 12 mg/kg vs. placebo). Change in the coronary artery score was −0.022, −0.036, −0.022, and −0.015 mm (nominal P = 0.25, 0.99, 0.55), and change in the cumulative coronary stenosis score was −0.51, 2.65, 0.71, and −0.77% (compared with placebo, nominal P = 0.85 for 12 mg/kg and nominal P = 0.01 for 3 mg/kg). The number of patients with major cardiovascular events was 10 (8.3%), 16 (13.3%), 17 (13.7%), and 12 (9.8%) in the four groups. Conclusion: CER-001 infusions did not reduce coronary atherosclerosis on IVUS and QCA when compared with placebo. Whether CER-001 administered in other regimens or to other populations could favourably affect atherosclerosis must await further study. Name of the trial registry: Clinicaltrials.gov; Registry's URL: http://clinicaltrials.gov/ct2/show/NCT01201837?term=cer-001&rank=2; Trial registration number: NCT01201837

    Effects of the high-density lipoprotein mimetic agent CER-001 on coronary atherosclerosis in patients with acute coronary syndromes: a randomized trial†

    Get PDF
    Aim High-density lipoproteins (HDLs) have several potentially protective vascular effects. Most clinical studies of therapies targeting HDL have failed to show benefits vs. placebo. Objective To investigate the effects of an HDL-mimetic agent on atherosclerosis by intravascular ultrasonography (IVUS) and quantitative coronary angiography (QCA). Design and setting A prospective, double-blinded, randomized trial was conducted at 51 centres in the USA, the Netherlands, Canada, and France. Intravascular ultrasonography and QCA were performed to assess coronary atherosclerosis at baseline and 3 (2-5) weeks after the last study infusion. Patients Five hundred and seven patients were randomized; 417 and 461 had paired IVUS and QCA measurements, respectively. Intervention Patients were randomized to receive 6 weekly infusions of placebo, 3 mg/kg, 6 mg/kg, or 12 mg/kg CER-001. Main outcome measures The primary efficacy parameter was the nominal change in the total atheroma volume. Nominal changes in per cent atheroma volume on IVUS and coronary scores on QCA were also pre-specified endpoints. Results The nominal change in the total atheroma volume (adjusted means) was −2.71, −3.13, −1.50, and −3.05 mm3 with placebo, CER-001 3 mg/kg, 6 mg/kg, and 12 mg/kg, respectively (primary analysis of 12 mg/kg vs. placebo: P = 0.81). There was also no difference among groups for the nominal change in per cent atheroma volume (0.02, −0.02, 0.01, and 0.19%; nominal P = 0.53 for 12 mg/kg vs. placebo). Change in the coronary artery score was −0.022, −0.036, −0.022, and −0.015 mm (nominal P = 0.25, 0.99, 0.55), and change in the cumulative coronary stenosis score was −0.51, 2.65, 0.71, and −0.77% (compared with placebo, nominal P = 0.85 for 12 mg/kg and nominal P = 0.01 for 3 mg/kg). The number of patients with major cardiovascular events was 10 (8.3%), 16 (13.3%), 17 (13.7%), and 12 (9.8%) in the four groups. Conclusion CER-001 infusions did not reduce coronary atherosclerosis on IVUS and QCA when compared with placebo. Whether CER-001 administered in other regimens or to other populations could favourably affect atherosclerosis must await further study. Name of the trial registry: Clinicaltrials.gov; Registry's URL: http://clinicaltrials.gov/ct2/show/NCT01201837?term=cer-001&rank=2; Trial registration number: NCT0120183

    Efficacies of the new Paclitaxel-eluting Coroflex Please™ Stent in percutaneous coronary intervention; comparison of efficacy between Coroflex Please™ and Taxus™ (ECO-PLEASANT) trial: study rationale and design

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous randomized trials have showed the superiority of Paclitaxel-eluting stent over bare metal stent in angiographic and clinical outcomes. Coroflex Please™ stent is a newly developed drug eluting stent using the Coroflex™ stent platform combined with the drug paclitaxel contained in a polymer coating. PECOPS I trial, one-arm observational study, showed that the clinical and angiographic outcomes of Coroflex Please™ stent were within the range of those of Taxus, the 1<sup>st </sup>generation paclitaxel-eluting stent (PES). However, there have been no studies directly comparing the Coroflex Please™ stent with the Taxus Liberte™ stent that is the newest version of Taxus. Therefore, prospective, randomized trial is required to demonstrate the non-inferiority of Coroflex Please™ stent compared with Taxus Liberte™ stent in a head-to-head manner.</p> <p>Methods</p> <p>In the comparison of Efficacy between COroflex PLEASe™ ANd Taxus™ stent(ECO-PLEASANT) trial, approximately 900 patients are being prospectively and randomly assigned to the either type of Coroflex Please™ stent and Taxus Liberte™ stent via web-based randomization. The primary endpoint is clinically driven target vessel revascularization at 9 months. The secondary endpoints include major cardiac adverse events, target vessel failure, stent thrombosis and angiographic efficacy endpoints.</p> <p>Discussion</p> <p>The ECO-PLEASANT trial is the study not yet performed to directly compare the efficacy and safety of the Coroflex Please™ versus Taxus Liberte™ stent. On the basis of this trial, we will be able to find out whether the Coroflex Please™ stent is non-inferior to Taxus Liberte™ stent or not.</p> <p>Trial registration</p> <p>ClinicalTrials.gov number, NCT00699543.</p
    corecore