1,387 research outputs found

    Evaluating the Factor Structure of the Emotion Dysregulation Scale-Short (EDS-s): A Preliminary Study

    Get PDF
    Emotion dysregulation (ED) can be considered a psychopathological transdiagnostic dimension, the presence of which should be reliably screened in clinical settings. The aim of the current study was to validate the Italian version of the Emotion Dysregulation Scale-short (EDS-s), a brief self-report tool assessing emotion dysregulation, in a non-clinical sample of 1087 adults (768 women and 319 men). We also assessed its convergent validity with scales measuring binge eating and general psychopathology. Structural equation modeling suggested the fit of a one-factor model refined with correlations between the errors of three pairs of items (χ2 = 255.56, df = 51, p < 0.001, RMSEA = 0.08, CFI = 0.94, TLI = 0.93, SRMR = 0.04). The EDS-s demonstrated satisfactory internal consistency (ordinal alpha = 0.94). Moreover, EDS-s scores partly explained the variance of both binge eating (0.35, p < 0.001) and general psychopathology (0.60, p < 0.001). In conclusion, the EDS-s can be considered to be a reliable and valid measure of ED

    Criticality and conformality in the random dimer model

    Get PDF
    In critical systems, the effect of a localized perturbation affects points that are arbitrarily far from the perturbation location. In this paper, we study the effect of localized perturbations on the solution of the random dimer problem in two dimensions. By means of an accurate numerical analysis, we show that a local perturbation of the optimal covering induces an excitation whose size is extensive with finite probability. We compute the fractal dimension of the excitations and scaling exponents. In particular, excitations in random dimer problems on nonbipartite lattices have the same statistical properties of domain walls in spin glass. Excitations produced in bipartite lattices, instead, are compatible with a loop-erased self-avoiding random walk process. In both cases, we find evidence of conformal invariance of the excitations that is compatible with SLEÎș with parameter Îș depending on the bipartiteness of the underlying lattice onl

    Low-field Instabilities in Nb3_{3}Sn Multifilamentary Wires: the Possible Role of Unreacted Nb

    Get PDF
    We report an experimental study aiming to demonstrate the not negligible role of unreacted Nb on the magnetic instabilities in superconducting Nb3_{3}Sn multifilamentary wires, observable through partial flux jumps at magnetic field values below 0.5 T. The analysed wires were recently developed for use as dipoles required in future high-energy proton accelerators and are based on powder-in-tube technology. We studied both unreacted (only involving Nb filaments) and reacted wires, finding flux jump instabilities in both cases when performing magnetic measurements. The results can be interpreted on the basis of the critical state model and are coherent with the intrinsic stability criterion

    Finite element stress analysis of the CMS magnet coil

    Get PDF
    The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs)

    Study of coupling loss on bi-columnar BSCCO/Ag tapes by a.c. susceptibility measurements

    Full text link
    Coupling losses were studied in composite tapes containing superconducting material in the form of two separate stacks of densely packed filaments embedded in a metallic matrix of Ag or Ag alloy. This kind of sample geometry is quite favorable for studying the coupling currents and in particular the role of superconducting bridges between filaments. By using a.c. susceptibility technique, the electromagnetic losses as function of a.c. magnetic field amplitude and frequency were measured at the temperature T = 77 K for two tapes with different matrix composition. The length of samples was varied by subsequent cutting in order to investigate its influence on the dynamics of magnetic flux penetration. The geometrical factor χ0\chi_0 which takes into account the demagnetizing effects was established from a.c. susceptibility data at low amplitudes. Losses vs frequency dependencies have been found to agree nicely with the theoretical model developed for round multifilamentary wires. Applying this model, the effective resistivity of the matrix was determined for each tape, by using only measured quantities. For the tape with pure silver matrix its value was found to be larger than what predicted by the theory for given metal resistivity and filamentary architecture. On the contrary, in the sample with a Ag/Mg alloy matrix, an effective resistivity much lower than expected was determined. We explain these discrepancies by taking into account the properties of the electrical contact of the interface between the superconducting filaments and the normal matrix. In the case of soft matrix of pure Ag, this is of poor quality, while the properties of alloy matrix seem to provoke an extensive creation of intergrowths which can be actually observed in this kind of samples.Comment: 20 pages 11 figure, submitted to Superconductor Science and Technolog

    Neurocognitive and Psychopathological Predictors of Weight Loss After Bariatric Surgery: A 4-Year Follow-Up Study

    Get PDF
    Twenty to thirty percent of patients experience weight regain at mid and long-term follow- up. Impaired cognitive functions are prevalent in people suffering from obesity and in those with binge eating disorder, thereby, affecting the weight-loss outcomes. The aim of our study was to investigate neurocognitive and psychopathological predictors of surgical efficacy in terms of percentage of excess weight loss (%EWL) at follow-up intervals of one year and 4-year. Psychosocial evaluation was completed in a sample of 78 bariatric surgery candidates and included psychometric instruments and a cognitive battery of neuropsychological tests. A schedule of 1-year and 4-year follow-ups was implemented. Wisconsin Sorting Card Test total correct responses, scores on the Raven’s Progressive Matrices Test, and age predicted %EWL at, both, early and long-term periods after surgery while the severity of pre-operative binge eating (BED) symptoms were associated with lower %EWL only four years after the operation. Due to the role of pre-operative BED in weight loss maintenance, the affected patients are at risk of suboptimal response requiring ongoing clinical monitoring, and psychological and pharmacological interventions when needed. As a result of our findings and in keeping with the latest guidelines we encourage neuropsychological assessment of bariatric surgery candidates. This data substantiated the rationale of providing rehabilitative interventions tailored to cognitive domains and time specific to the goal of supporting patients in their post-surgical course

    Nb3_3Sn conductor development and characterization for NED

    Get PDF
    The main purpose of Next European Dipole (NED) project is to design and to build an Nb3_{3}Sn ~ 15 T dipole magnet. Due to budget constraints, NED is mainly focused on superconducting cable development and production. In this work, an update is given on the NED conductor development by Alstom-MSA and SMI, which uses, respectively, Internal-Tin-Diffusion and Powder-In-Tube methods, with the aim of reaching a non-copper critical current density of ~ 3000 A/mm2 at 12 T and 4.2 K. Characterization results, including critical current and magnetization data, are presented and discussed, as well, for conductors already developed by both companies for this project. SMI succeeded to produce a strand with 50 ”m diameter filaments and with a critical current of ~ 1400 A at 4.2 K and 12 T, corresponding to a non-copper critical current density of ~ 2500 A/mm2. Cabling trials with this strand were successfully carried out at LBNL

    Insertion Magnets

    Full text link
    Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.Comment: 19 pages, Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Repor

    Status of the Super-B factory Design

    Full text link
    The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 1036^{36} cm−2^{-2} sec−1^{-1}. This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the ΄\Upsilon(4S) resonance. The present design is based on extremely low emittance beams colliding at a large Piwinski angle to allow very low ÎČy⋆\beta_y^\star without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and allowing for a higher beam-beam parameter. The project has flexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal polarization of the electron beam at the Interaction Point. Optimized for best colliding-beam performance, the facility may also provide high-brightness photon beams for synchrotron radiation applications
    • 

    corecore