29 research outputs found

    Contourite depositional system after the exit of a strait: Case study from the late Miocene South Rifian Corridor, Morocco

    Get PDF
    Idealized facies of bottom current deposits (contourites) have been established for fine-grained contourite drifts in modern deep-marine sedimentary environments. Their equivalent facies in the ancient record however are only scarcely recognized due to the weathered nature of most fine-grained deposits in outcrop. Facies related to the erosional elements (i.e. contourite channels) of contourite depositional systems have not yet been properly established and related deposits in outcrop appear non-existent. To better understand the sedimentary facies and facies sequences of contourites, the upper Miocene contourite depositional systems of the South Rifian Corridor (Morocco) is investigated. This contourite depositional system formed by the dense palaeo-Mediterranean Outflow Water. Foraminifera assemblages were used for age-constraints (7.51 to 7.35 Ma) and to determine the continental slope depositional domains. Nine sedimentary facies have been recognized based on lithology, grain-size, sedimentary structures and biogenic structures. These facies were subsequently grouped into five facies associations related to the main interpreted depositional processes (hemipelagic settling, contour currents and gravity flows). The vertical sedimentary facies succession records the tectonically induced, southward migration of the contourite depositional systems and the intermittent behaviour of the palaeo-Mediterranean Outflow Water, which is mainly driven by precession and millennial-scale climate variations. Tides substantially modulated the palaeo-Mediterranean Outflow Water on a sub-annual scale. This work shows exceptional examples of muddy and sandy contourite deposits in outcrop by which a facies distribution model from the proximal continental slope, the contourite channel to its adjacent contourite drift, is proposed. This model serves as a reference for contourite recognition both in modern environments and the ancient record. Furthermore, by establishing the hydrodynamics of overflow behaviour a framework is provided that improves process-based interpretation of deep-water bottom current deposits

    Oceanographic processes and products around the Iberian margin: a new multidisciplinary approach

    Get PDF
    Our understanding of the role of bottom currents and associated oceanographic processes (e.g, overflows, barotropic tidal currents) including intermittent processes (e.g, vertical eddies, deep sea storms, horizontal vortices, internal waves and tsunamis) is rapidly evolving. Many deep-water processes remain poorly understood due to limited direct observations, but may generate significant depositional and erosional features on both short-and long-term time scales. This paper describes these oceanographic processes and examines their potential role in the sedimentary features around the Iberian margin. The paper explores the implications of the processes studied, given their secondary role relative to other factors such as mass-transport and turbiditic processes. An integrated interpretation of these oceanographic processes requires an understanding of contourites, sea-floor features, their spatial and temporal evolution, and the near-bottom flows that form them. Given their complex, three-dimensional and temporally-variable nature, integration of these processes into sedimentary, oceanographic and climatological frameworks will require a multidisciplinary approach that includes Geology, Physical Oceanography, Paleoceanography and Benthic Biology. This approach will synthesize oceanographic data, seafloor morphology, sediments and seismic images to improve our knowledge of permanent and intermittent processes around Iberia, and evaluate their conceptual and regional role in the sedimentary evolution of the margin. © 2015, Instituto Geologico y Minero de Espana. All rights reservedEl conocimiento del papel de las corrientes de fondo y los procesos oceanográficos asociados (overflows, corrientes de marea barotrópicas, etc), incluyendo procesos intermitentes (eddies, tormentas profundas, ondas internas, tsunamis, etc), está evolucionando rápidamente. Muchos de estos procesos son poco conocidos, en parte debido a que las observaciones directas son limitadas, si bien pueden generar importantes rasgos deposicionales y/o erosivos a escalas temporales de corto o largo periodo. Este artículo describe dichos procesos oceanográficos y examina su influencia en la presencia de rasgos sedimentarios alrededor del margen Ibérico. El trabajo discute las implicaciones de dichos procesos y el papel secundario que juegan en relación a otros factores tales como los procesos de transporte gravitacionales en masa y los turbidíticos. Para un mejor conocimiento de la sedimentación marina profunda, y en concreto de los sistemas contorníticos, se requiere de una interpretación de estos procesos oceanográficos, cuál es su evolución espacial y temporal, cómo afectan a las corrientes de fondo y cómo se ven afectados por la topografía submarina. Sin embargo, dada su complejidad y su variable naturaleza tridimensional y temporal, es necesario que estos procesos se integren en un marco sedimentológico, oceanográfico y climatológico con un enfoque multidisciplinar que incluyan la Geología, la Oceanografía Física, la Paleoceanografía y la Biología bentónica. Esta integración requiere de una mayor compilación de datos oceanográficos, de un mejor conocimiento de la morfología del fondo marino, y de una mejor caracterización de los sedimentos en ambientes profundos. Todo ello permitirá mejorar nuestro conocimiento de los procesos permanentes e intermitentes alrededor de Iberia y evaluar su verdadero efecto en la evolución sedimentaria delos márgenes continentales que le rodeanPostprint0,000

    ATP5H/KCTD2 locus is associated with Alzheimer's disease risk

    Get PDF
    To identify loci associated with Alzheimer disease, we conducted a three-stage analysis using existing genome-wide association studies (GWAS) and genotyping in a new sample. In Stage I, all suggestive single-nucleotide polymorphisms (at P<0.001) in a previously reported GWAS of seven independent studies (8082 Alzheimer's disease (AD) cases; 12 040 controls) were selected, and in Stage II these were examined in an in silico analysis within the Cohorts for Heart and Aging Research in Genomic Epidemiology consortium GWAS (1367 cases and 12904 controls). Six novel signals reaching P<5 × 10-6 were genotyped in an independent Stage III sample (the Fundació ACE data set) of 2200 sporadic AD patients and 2301 controls. We identified a novel association with AD in the adenosine triphosphate (ATP) synthase, H+ transporting, mitochondrial F0 (ATP5H)/Potassium channel tetramerization domain-containing protein 2 (KCTD2) locus, which reached genome-wide significance in the combined discovery and genotyping sample (rs11870474, odds ratio (OR)=1.58, P=2.6 × 10 -7 in discovery and OR=1.43, P=0.004 in Fundació ACE data set; combined OR=1.53, P=4.7 × 10 -9). This ATP5H/KCTD2 locus has an important function in mitochondrial energy production and neuronal hyperpolarization during cellular stress conditions, such as hypoxia or glucose deprivation

    Effectiveness of an mHealth intervention combining a smartphone app and smart band on body composition in an overweight and obese population: Randomized controlled trial (EVIDENT 3 study)

    Get PDF
    Background: Mobile health (mHealth) is currently among the supporting elements that may contribute to an improvement in health markers by helping people adopt healthier lifestyles. mHealth interventions have been widely reported to achieve greater weight loss than other approaches, but their effect on body composition remains unclear. Objective: This study aimed to assess the short-term (3 months) effectiveness of a mobile app and a smart band for losing weight and changing body composition in sedentary Spanish adults who are overweight or obese. Methods: A randomized controlled, multicenter clinical trial was conducted involving the participation of 440 subjects from primary care centers, with 231 subjects in the intervention group (IG; counselling with smartphone app and smart band) and 209 in the control group (CG; counselling only). Both groups were counselled about healthy diet and physical activity. For the 3-month intervention period, the IG was trained to use a smartphone app that involved self-monitoring and tailored feedback, as well as a smart band that recorded daily physical activity (Mi Band 2, Xiaomi). Body composition was measured using the InBody 230 bioimpedance device (InBody Co., Ltd), and physical activity was measured using the International Physical Activity Questionnaire. Results: The mHealth intervention produced a greater loss of body weight (–1.97 kg, 95% CI –2.39 to –1.54) relative to standard counselling at 3 months (–1.13 kg, 95% CI –1.56 to –0.69). Comparing groups, the IG achieved a weight loss of 0.84 kg more than the CG at 3 months. The IG showed a decrease in body fat mass (BFM; –1.84 kg, 95% CI –2.48 to –1.20), percentage of body fat (PBF; –1.22%, 95% CI –1.82% to 0.62%), and BMI (–0.77 kg/m2, 95% CI –0.96 to 0.57). No significant changes were observed in any of these parameters in men; among women, there was a significant decrease in BMI in the IG compared with the CG. When subjects were grouped according to baseline BMI, the overweight group experienced a change in BFM of –1.18 kg (95% CI –2.30 to –0.06) and BMI of –0.47 kg/m2 (95% CI –0.80 to –0.13), whereas the obese group only experienced a change in BMI of –0.53 kg/m2 (95% CI –0.86 to –0.19). When the data were analyzed according to physical activity, the moderate-vigorous physical activity group showed significant changes in BFM of –1.03 kg (95% CI –1.74 to –0.33), PBF of –0.76% (95% CI –1.32% to –0.20%), and BMI of –0.5 kg/m2 (95% CI –0.83 to –0.19). Conclusions: The results from this multicenter, randomized controlled clinical trial study show that compared with standard counselling alone, adding a self-reported app and a smart band obtained beneficial results in terms of weight loss and a reduction in BFM and PBF in female subjects with a BMI less than 30 kg/m2 and a moderate-vigorous physical activity level. Nevertheless, further studies are needed to ensure that this profile benefits more than others from this intervention and to investigate modifications of this intervention to achieve a global effect

    7th Drug hypersensitivity meeting: part two

    Get PDF
    No abstract availabl
    corecore