2,467 research outputs found

    Strongly lensed SNe Ia in the era of LSST: observing cadence for lens discoveries and time-delay measurements

    Full text link
    The upcoming Large Synoptic Survey Telescope (LSST) will detect many strongly lensed Type Ia supernovae (LSNe Ia) for time-delay cosmography. This will provide an independent and direct way for measuring the Hubble constant H0H_0, which is necessary to address the current 4.4σ4.4 \sigma tension in H0H_0 between the local distance ladder and the early Universe measurements. We present a detailed analysis of different observing strategies for the LSST, and quantify their impact on time-delay measurement between multiple images of LSNe Ia. For this, we produced microlensed mock-LSST light curves for which we estimated the time delay between different images. We find that using only LSST data for time-delay cosmography is not ideal. Instead, we advocate using LSST as a discovery machine for LSNe Ia, enabling time delay measurements from follow-up observations from other instruments in order to increase the number of systems by a factor of 2 to 16 depending on the observing strategy. Furthermore, we find that LSST observing strategies, which provide a good sampling frequency (the mean inter-night gap is around two days) and high cumulative season length (ten seasons with a season length of around 170 days per season), are favored. Rolling cadences subdivide the survey and focus on different parts in different years; these observing strategies trade the number of seasons for better sampling frequency. In our investigation, this leads to half the number of systems in comparison to the best observing strategy. Therefore rolling cadences are disfavored because the gain from the increased sampling frequency cannot compensate for the shortened cumulative season length. We anticipate that the sample of lensed SNe Ia from our preferred LSST cadence strategies with rapid follow-up observations would yield an independent percent-level constraint on H0H_0.Comment: 25 pages, 22 figures; accepted for publication in A&

    Emotional distress, anxiety, and depression in South Asians with long-term conditions: a qualitative systematic review.

    Get PDF
    BACKGROUND: People with physical-mental comorbidity have a poorer quality of life, worse clinical outcomes, and increased mortality compared with people with physical conditions alone. People of South Asian (SA) origin are the largest minority group in the UK and are more likely to have long-term conditions (LTCs) such as diabetes and heart disease. People of SA origin are less likely to recognise symptoms that may represent mental health problems. AIM: To explore how people of SA origin with LTCs understand, experience, and seek help for emotional distress, depression, and anxiety. DESIGN AND SETTING: Systematic review of qualitative studies exploring emotional distress in people of SA origin with diabetes or coronary heart disease, within primary and community care settings worldwide. METHOD: Comprehensive searches of eight electronic databases from inception to 1 September 2021 were undertaken. Data extracted included study characteristics, and understanding, experience, and help-seeking behaviour for emotional distress. Thematic synthesis was undertaken. The Critical Appraisal Skills Programme (CASP) checklist for qualitative studies was used to assess quality of articles, and Confidence in the Evidence from Reviews of Qualitative Research (GRADE-CERQual) used to determine the overall strength of evidence. RESULTS: Twenty-one studies from 3165 unique citations were included. Three main themes were identified. Understanding of emotional distress: non-medical terminology used, such as 'tension', and a complex relationship between emotional and physical illness. Experiences of emotional distress: multiple forms of inequality, distress at diagnosis of their LTC, cultural factors, and sex differences. Help-seeking behaviour: self-management, support from family, friends, and faith, and inadequate clinical support. CONCLUSION: This review provides a greater understanding of the conceptualisation of emotional distress in the context of LTCs by people of SA origin, to support improvement in its recognition and management

    Design of Multicationic Copper-Bearing Layered Double Hydroxides for Catalytic Application in Biorefinery

    Get PDF
    Ethanol has been used as a renewable hydrogen-donor in the conversion of a lignin model molecule in subcritical conditions. Noble metal-free porous mixed oxides, obtained by activation of Cu-Ni-Al and Cu-Ni-Fe layered double hydroxide (LDH) precursors, have been used as heterogeneous catalysts for Meerwein-Ponndorf-Verley (MPV) hydrogen transfer and further hydrogenation by ethanol dehydrogenation products. Both the Cu/(Cu+Ni) ratio and the nature of the trivalent cation (Al or Fe) affect the activity of the catalysts, as well as the selectivity towards the different steps of the hydrogenation reactions and the cleavage of lignin-like phenylether bonds. Accounting for the peculiar behaviour of Cu2+ and M(III) cations in the synthesis of LDHs, the coprecipitation of the precursors has been monitored by titration experiments. Structural and textural properties of the catalysts are closely related to the composition of the LDH precursors

    Vaccines against toxoplasma gondii : challenges and opportunities

    Get PDF
    Development of vaccines against Toxoplasma gondii infection in humans is of high priority, given the high burden of disease in some areas of the world like South America, and the lack of effective drugs with few adverse effects. Rodent models have been used in research on vaccines against T. gondii over the past decades. However, regardless of the vaccine construct, the vaccines have not been able to induce protective immunity when the organism is challenged with T. gondii, either directly or via a vector. Only a few live, attenuated T. gondii strains used for immunization have been able to confer protective immunity, which is measured by a lack of tissue cysts after challenge. Furthermore, challenge with low virulence strains, especially strains with genotype II, will probably be insufficient to provide protection against the more virulent T. gondii strains, such as those with genotypes I or II, or those genotypes from South America not belonging to genotype I, II or III. Future studies should use animal models besides rodents, and challenges should be performed with at least one genotype II T. gondii and one of the more virulent genotypes. Endpoints like maternal-foetal transmission and prevention of eye disease are important in addition to the traditional endpoint of survival or reduction in numbers of brain cysts after challenge

    Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    Get PDF
    In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Full text link
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5<∣η∣<2.21.5 < \mid\eta\mid < 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 μ\murad pitch arranged in eight η\eta-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO2_{2} 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 μ\murad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ±\pm 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 ±\pm 1.6 (stat)] μ\murad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by ∼\sim 10 μ\murad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ±\pm 2.5 stat] μ\murad is measured, consistent with the expected resolution of strip-pitch/12\sqrt{12} = 131.3 μ\murad. Other η\eta-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference adde

    Charged particle detection performance of Gas Electron Multiplier (GEM) detectors for the upgrade of CMS endcap muon system at the CERN LHC

    Get PDF
    The Compact Muon Solenoid (CMS) detector is one of the two general-purpose detectors at the CERN LHC. LHC will provide exceptional high instantaneous and integrated luminosity after second long shutdown. The forward region |η| ≥ 1:5 of CMS detector will face extremely high particle rates in tens of kHz/cm2 and hence it will affect the momentum resolution, efficiency and longevity of the muon detectors. Here, η is pseudorapidity defined as η = -ln(tan(θ/2)), where θ is the polar angle measured from z-axis. To overcome these issues the CMSGEM collaboration has proposed to install new large size rate capable Triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The first set of Triple GEM detectors will be installed in the GE1/1 region (1:6 <; |η| <; 2.2) of the muon endcap during the long shutdown 2 (LS2) of the LHC. Towards this goal, full size CMS Triple GEM detectors have been fabricated and tested at the CERN SPS, H2 and H4 test beam facility. The GEM detectors were operated with two gas mixtures: Ar/CO2 (70/30) and Ar/CO2/CF4 (45/15/40). In 2014, good quality data was collected during test beam campaigns. In this paper, the performance of the detectors is summarized based on their tracking efficiency and time resolution
    • …
    corecore