185 research outputs found
Dair approach in 7 infected total hip arthroplasties: our experience and current concepts of the literature
INTRODUCTION: Periprosthetic joint infection (PJI) is one of the most challenging complications following total hip arthroplasty. In early infection, within four to twelve weeks from surgery, debridement, antibiotics and implant retention (DAIR) can be the initial treatment. The aim of this study is to report our case series and review current concepts reported in the literature about this topic. MATERIALS AND METHODS: This was an observational cohort study that included 7 patients managed with DAIR for PJI following primary total hip replacement (THR) between 2014 and 2020. Inclusion criteria were a primary THR, direct anterior or lateral approach, DAIR procedure, and PJI. Exclusion criteria were a PJI following a revision total hip replacement or hemiarthroplasty, posterolateral approach, 1-stage revision, 2-stage revision, and Girdlestone procedure without prior DAIR. For each patient demographic characteristics, laboratory values, microorganisms involved, antibiotic therapy and outcome at one-year follow-up were registered. RESULTS: The mean duration between THR and DAIR was 19 days. In all cases only one DAIR procedure was performed. Most infections were caused by Staphylococcus aureus (4 cases) [one methicillin resistant (MRSA)]. The other infections were caused by Streptococcus agalactiae, Staphylococcus coagulase negative and Escherichia coli. At the final follow-up, the procedure was considered as successful in 6 out of 7 patients (85%). The one with unsuccessful outcome underwent to a two-stage revision. DISCUSSION: Our results were comparable with those of a recent systematic review of the literature. Factors that have been postulated to influence the outcome of DAIR in the management of PJIs include the timing and numbers of debridement, the exchange of components, the responsible microorganism and the duration of antibiotic treatment. In conclusion, the outcomes following DAIR are better as the indications are refined and risk factors identified. PJI prevention remains the key but the current literature still lacks well documented and effective PJI prevention protocols. (www.actabiomedica.it)
Is there a relation between clinical scores and serum ion levels after MoM-THA? One year results in 383 implants
Background and aim of the work: Adverse reaction to metal debris is the major cause of the high revision rates of metal on metal hip implants with femoral head size ≥ 36mm. Health authorities recommend regular surveillance even for asymptomatic individuals. The main investigations used are Co+ and Cr+ serum levels, x-rays and, eventually, ultrasound and MARS-MRI. Clinic is also assessed. The aim of this study is to identify if there is a relation between ion levels and the clinical scores in order to evaluate the outcome and plan the correct management after this type of implant. Methods: 383 subjects were included and divided in 3 groups (serum ion levels >, < and >60 µg/L). Co+, Cr+, HHS and OHS results of 1 year (2017) were analysed in order to show a correlation between ion levels and clinical scores. Results: Clinical scores were similar in group 1 and 2. Differences were observed comparing the group 1 and 2 with group 3 for both variables. Discussion and Conclusions: Surveillance algorithms have been introduced by health authorities. Nevertheless, the indication to revision surgery is not simple especially in those cases in which a discrepancy between clinic and investigations is present. In this study clinical scores seem to be less important than ion levels in the evaluation of outcomes and in order to plan the correct management in the majority of cases. Larger studies are needed to highlight the real importance of clinical scores in the decision making after these type of implants
Curvature-driven ac-assisted creep dynamics of magnetic domain walls
The dynamics of micrometer-sized magnetic domains in ultrathin ferromagnetic films is so dramatically slowed down by quenched disorder that the spontaneous elastic tension collapse becomes unobservable at ambient temperature. By magneto-optical imaging we show that a weak zero-bias ac magnetic field can assist such curvature-driven collapse, making the area of a bubble to reduce at a measurable rate, in spite of the negligible effect that the same curvature has on the average creep motion driven by a comparable dc field. An analytical model explains this phenomenon quantitatively.Fil: Domenichini, Pablo Exequiel. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Ciudad Universitaria. Instituto de FĂsica de Buenos Aires. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de FĂsica de Buenos Aires; ArgentinaFil: Paris, F.. ComisiĂłn Nacional de EnergĂa AtĂłmica. Centro AtĂłmico Bariloche; ArgentinaFil: Capeluto, Maria Gabriela. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Ciudad Universitaria. Instituto de FĂsica de Buenos Aires. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de FĂsica de Buenos Aires; ArgentinaFil: Granada, Mara. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Oficina de Coordinacion Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Bariloche | Comision Nacional de Energia Atomica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Bariloche.; ArgentinaFil: George, J. M.. UniversitĂ© Paris Sud; FranciaFil: Pasquini, Gabriela. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Ciudad Universitaria. Instituto de FĂsica de Buenos Aires. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de FĂsica de Buenos Aires; ArgentinaFil: Kolton, Alejandro Benedykt. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y NanotecnologĂa. Unidad Ejecutora Instituto de Nanociencia y NanotecnologĂa - Nodo Bariloche | ComisiĂłn Nacional de EnergĂa AtĂłmica. Unidad Ejecutora Instituto de Nanociencia y NanotecnologĂa. Unidad Ejecutora Instituto de Nanociencia y NanotecnologĂa - Nodo Bariloche; Argentin
A GFP-Tagged Gross Deletion on Chromosome 1 Causes Malignant Peripheral Nerve Sheath Tumors and Carcinomas in Zebrafish
Malignant peripheral nerve sheath tumors (MPNSTs) are highly aggressive soft-tissue sarcomas, characterized by complex karyotypes. The molecular bases of such malignancy are poorly understood and efficient targeted molecular therapies are currently lacking. Here we describe a novel zebrafish model of MPNSTs, represented by the transgenic mutant line Tg(-8.5nkx2.2a:GFP)ia2. ia2 homozygous animals displayed embryonic lethality by 72 hpf, while the heterozygotes develop visible tumor masses with high frequency in adulthood. Histological and immunohistochemical examination revealed aggressive tumors with either mesenchymal or epithelial features. The former (54% of the cases) arose either in the abdominal cavity, or as intrathecal/intraspinal lesions and is composed of cytokeratin-negative spindle cells with fascicular/storiform growth pattern consistent with zebrafish MPNSTs. The second histotype was composed by polygonal or elongated cells, immunohistochemically positive for the pan-cytokeratin AE1/AE3. The overall histologic and immunohistochemical features were consistent with a malignant epithelial neoplasm of possible gastrointestinal/pancreatic origin. With an integrated approach, based on microsatellite (VNTR) and STS markers, we showed that ia2 insertion, in Tg(-8.5nkx2.2a:GFP)ia2 embryos, is associated with a deletion of 15.2 Mb in the telomeric portion of chromosome 1. Interestingly, among ia2 deleted genes we identified the presence of the 40S ribosomal protein S6 gene that may be one of the possible drivers for the MPNSTs in ia2 mutants.Thanks to the peculiar features of zebrafish as animal model of human cancer (cellular and genomic similarity, transparency and prolificacy) and the GFP tag, the Tg(-8.5nkx2.2a:GFP)ia2 line provides a manageable tool to study in vivo with high frequency MPNST biology and genetics, and to identify, in concert with the existing zebrafish MPNST models, conserved relevant mechanisms in zebrafish and human cancer development
Digital droplet PCR is a specific and sensitive tool for detecting IDH2 mutations in acute myeloid leukemia patients
Isocitrate dehydrogenase 1 and 2 (IDH1 and IDH2) interfere with cellular metabolism contributing to oncogenesis. Mutations of IDH2 at R140 and R172 residues are observed in 20% of acute myeloid leukemias (AML), and the availability of the IDH2 inhibitor Enasidenib made IDH2 mutational screening a clinical need. The aim of this study was to set a new quantitative polymerase chain reaction (PCR) technique, the drop-off digital droplet PCR (drop-off ddPCR), as a sensitive and accurate tool for detecting IDH2 mutations. With this technique we tested 60 AML patients. Sanger sequencing identified 8/60 (13.5%) mutated cases, while ddPCR and the amplification refractory mutation system (ARMS) PCR, used as a reference technique, identified mutations in 13/60 (21.6%) cases. When the outcome of IDH2-mutated was compared to that of wild-type patients, no significant difference in terms of quality of response, overall survival, or progression-free survival was observed. Finally, we monitored IDH2 mutations during follow-up in nine cases, finding that IDH2 can be considered a valid marker of minimal residual disease (MRD) in 2/3 of our patients. In conclusion, a rapid screening of IDH2 mutations is now a clinical need well satisfied by ddPCR, but the role of IDH2 as a marker for MRD still remains a matter of debate
Recommended from our members
Fluid Structure Interaction of Multiple Flapping Filaments Using Lattice Boltzmann and Immersed Boundary Methods
The problem of flapping filaments in an uniform incoming flow is tackled using a Lattice Boltzmann—Immersed Boundary method. The fluid momentum equations are solved on a Cartesian uniform lattice while the beating filaments are tracked through a series of markers, whose dynamics are functions of the forces exerted by the fluid, the filament flexural rigidity and the tension. The instantaneous wall conditions on the filament are imposed via a system of singular body forces, consistently discretised on the lattice of the Boltzmann equation. We first consider the case of a single beating filament, and then the case of multiple beating filaments in a side-by-side configuration, focussing on the modal behaviour of the whole dynamical systems
Results of the Patient-Related Outcomes of Mechanical lead Extraction Techniques (PROMET) study: a multicentre retrospective study on advanced mechanical lead extraction techniques.
AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety
Recurrences of ventricular tachycardia after stereotactic arrhythmia radioablation arise outside the treated volume: analysis of the swiss cohort
BACKGROUND AND AIMS
Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analyzed recurrences in our patients after STAR.
METHODS
From 09.2017 to 01.2020, 20 patients (68±8y, LVEF 37±15%) suffering from refractory VT were enrolled, 16/20 with a history of at least 1 electrical storm. Before STAR, an invasive electro-anatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23±2Gy was delivered to the planning target volume (PTV).
RESULTS
The median ablation volume was 26 ml (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in proximity of the treated substrate in 9 cases, remote from the PTV in 3 cases and involved a larger substrate over ≥3 LV segments in 2 cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR.
CONCLUSION
STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude
- …