451 research outputs found

    Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis

    Get PDF
    \ua9 2024, The Author(s). Background: Positron emission tomography–magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis. Methods: Ten patients being treated with ano-rectal radiotherapy received a 18 F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of p≤ 0.05 / 7 = 0.007 . Equivalence margins of \ub1 3.5 % were used. Results: Mean whole-image SUV differences were −0.02% (sCTAC) compared to −3.0% (MRAC), with larger differences in the bone regions (−0.5% to −16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients ≥ 0.987 . However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in SUV max were 1.0 \ub1 0.8 % (\ub1 standard error, sCTAC) and - 4.6 \ub1 0.9 % (MRAC), and 1.0 \ub1 0.7 % (sCTAC) and - 4.3 \ub1 0.8 % (MRAC) in SUV mean . The sCTAC was statistically equivalent to CTAC within a \ub1 3.5 % equivalence margin for SUV max and SUV mean (p= 0.007 and p= 0.002), whereas the MRAC was not (p= 0.88 and p= 0.83). Conclusion: Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner

    Whole-body vibration training induces hypertrophy of the human patellar tendon

    Get PDF
    I Brage finner du siste tekst-versjon av artikkelen, og den kan inneholde ubetydelige forskjeller fra forlagets pdf-versjon. Forlagets pdf-versjon finner du på onlinelibrary.wiley.com / In Brage you'll find the final text version of the article, and it may contain insignificant differences from the journal's pdf version. The definitive version is available at onlinelibrary.wiley.comAnimal studies suggest that regular exposure to whole-body vibration (WBV) induces an anabolic response in bone and tendon. However, the effects of this type of intervention on human tendon properties and its influence on the muscle-tendon unit function have never been investigated. The aim of this study was to investigate the effect of WBV training on the patellar tendon mechanical, material and morphological properties, the quadriceps muscle architecture and the knee extension torque–angle relationship. Fifty-five subjects were randomized into either a vibration, an active control, or an inactive control group. The active control subjects performed isometric squats on a vibration platform without vibration. Muscle and tendon properties were measured using ultrasonography and dynamometry. Vibration training induced an increase in proximal (6.3%) and mean (3.8%) tendon cross-sectional area, without any appreciable change in tendon stiffness and modulus or in muscle architectural parameters. Isometric torque at a knee angle of 90° increased in active controls (6.7%) only and the torque–angle relation remained globally unchanged in all groups. The present protocol did not appreciably alter knee extension torque production or the musculo-tendinous parameters underpinning this function. Nonetheless, this study shows for the first time that WBV elicits tendon hypertrophy in humans.Seksjon for fysisk prestasjonsevne / Department of Physical Performanc

    A Study of the PDGF Signaling Pathway with PRISM

    Get PDF
    In this paper, we apply the probabilistic model checker PRISM to the analysis of a biological system -- the Platelet-Derived Growth Factor (PDGF) signaling pathway, demonstrating in detail how this pathway can be analyzed in PRISM. We show that quantitative verification can yield a better understanding of the PDGF signaling pathway.Comment: In Proceedings CompMod 2011, arXiv:1109.104

    Region of Interest focused MRI to Synthetic CT Translation using Regression and Classification Multi-task Network

    Full text link
    In this work, we present a method for synthetic CT (sCT) generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. We propose a loss function that favors a spatially sparse region in the image. We harness the ability of a multi-task network to produce correlated outputs as a framework to enable localisation of region of interest (RoI) via classification, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task. We demonstrate how the multi-task network with RoI focused loss offers an advantage over other configurations of the network to achieve higher accuracy of performance. This is relevant to sCT where failure to accurately estimate high Hounsfield Unit values of bone could lead to impaired accuracy in clinical applications. We compare the dose calculation maps from the proposed sCT and the real CT in a radiation therapy treatment planning setup

    A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios

    Full text link
    The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, (q/m)p/(q/m)pˉ-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}} = 1.000000000003(16)1.000\,000\,000\,003 (16), is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of 1.9610271.96\cdot10^{-27}\,GeV (C..L.. 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEPcc_\text{cc}) for antimatter to a level of αg1<1.8107|\alpha_{g}-1| < 1.8 \cdot 10^{-7}, and enables the first differential test of the WEPcc_\text{cc} using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEPcc_\text{cc}-violating coefficient to αg,D1<0.030|\alpha_{g,D}-1|<0.030

    Current CONtrolled Transmit And Receive Coil Elements (C2ONTAR) for Parallel Acquisition and Parallel Excitation Techniques at High-Field MRI

    Get PDF
    A novel intrinsically decoupled transmit and receive radio-frequency coil element is presented for applications in parallel imaging and parallel excitation techniques in high-field magnetic resonance imaging. Decoupling is achieved by a twofold strategy: during transmission elements are driven by current sources, while during signal reception resonant elements are switched to a high input impedance preamplifier. To avoid B0 distortions by magnetic impurities or DC currents a resonant transmission line is used to relocate electronic components from the vicinity of the imaged object. The performance of a four-element array for 3 T magnetic resonance tomograph is analyzed by means of simulation, measurements of electromagnetic fields and bench experiments. The feasibility of parallel acquisition and parallel excitation is demonstrated and compared to that of a conventional power source-driven array of equivalent geometry. Due to their intrinsic decoupling the current-controlled elements are ideal basic building blocks for multi-element transmit and receive arrays of flexible geometry
    corecore