2,382 research outputs found

    Synthesis of 2-(2-hydroxyaryl)alkenylphosphonium salts from phosphine oxides via ring-closing ring-opening approach and their antimicrobial evaluation

    Get PDF
    © 2016 Elsevier LtdA new two-step synthesis of phosphonium salts from phosphine oxides using Grignard reagents is reported. This approach involves a cyclization of Z-dialkyl-(diaryl)[2-(5-chloro-2-hydroxyphenyl)-2-phenylvinyl]phosphine oxides under the action of sulfinyl chloride with the formation of 2,2-dialkyl(diaryl)-6-chloro-4-phenyl-2H-1,2-benzoxaphosphinin-2-ium chlorides followed by ring opening under the action of organomagnesium compounds. The method was successfully applied to prepare a series of a new phosphonium salts bearing phenolic moiety with a wide range of substituents at phosphorus atom. Synthesized phosphonium salts shows high antibacterial and antifungal in vitro activity and low toxicity towards human red blood cell

    Phosphineoxide-Chelated Europium(III) Nanoparticles for Ceftriaxone Detection

    Get PDF
    The present work demonstrates the optimization of the ligand structure in the series of bis(phosphine oxide) and ÎČ-ketophosphine oxide representatives for efficient coordination of Tb3+ and Eu3+ ions with the formation of the complexes exhibiting high Tb3+- and Eu3+-centered luminescence. The analysis of the stoichiometry and structure of the lanthanide complexes obtained using the XRD method reveals the great impact of the bridging group nature between two phosphine oxide moieties on the coordination mode of the ligands with Tb3+ and Eu3+ ions. The bridging imido-group facilitates the deprotonation of the imido- bis(phosphine oxide) ligand followed by the formation of tris-complexes. The spectral and PXRD analysis of the separated colloids indicates that the high stability of the tris-complexes provides their safe conversion into polystyrenesulfonate-stabilized colloids using the solvent exchange method. The red Eu3+-centered luminescence of the tris-complex exhibits the same specificity in the solutions and the colloids. The pronounced luminescent response on the antibiotic ceftriaxone allows for sensing the latter in aqueous solutions with an LOD value equal to 0.974 ÎŒM

    Performance of GEM detectors in high intensity particle beams

    Get PDF
    We describe extensive tests of Double GEM and Triple GEM detectors, including full size prototypes for the COMPASS experiment, exposed to high intensity muon, proton and pion beams at the Paul~Scherrer Institute and at CERN. The measurements aim at detecting problems possible under these operation conditions, the main concern being the occurrence of discharges induced by beam particles. Results on the dependence of the probability for induced discharges on the experimental environment are presented and discussed. Implications for the application of GEM~detectors in experiments at high luminosity colliders are illustrated

    partitioning of ecosystem respiration in a paludified shallow peat spruce forest in the southern taiga of european russia

    Get PDF
    Soil, tree stems, and ecosystem carbon dioxide fluxes were measured by chambers and eddy covariance methods in a paludified shallow-peat spruce forest in the southern taiga of European Russia (Tver region, 56 N 33 E) during the growing seasons of 2002‐2012. The site was established in 1998 as part of the EUROSIBERIAN CARBONFLUX project, an international field experiment examining atmosphere‐biosphere interaction in Siberia and European Russia. In all years the observed annual cumulative net ecosystem flux was positive (the forest was a source of carbon to the atmosphere). Soil and tree stem respiration was a significant part of the total ecosystem respiration (ER) in this paludified shallow-peat spruce forest. On average, 49% of the ER came from soil respiration. We found that the soil fluxes exhibited high seasonal variability, ranging from 0.7 to 10 mol m 2 s 1 . Generally, the soil respiration depended on the soil temperature and ground water level. In drought conditions, the soil respiration was low and did not depend on temperature. The stem respiration of spruces grew intensively in May, had permanently high values from June to the end of September, and in October it dramatically decreased. The tree stem respiration in midsummer was about 3‐5 mol m 2 s 1 for dominant trees and about 1‐2 mol m 2 s 1 for subdominant trees. The respiration of living tree stems was about 10‐20% of the ER

    Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    Get PDF
    In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Unexpected Role of α-Fetoprotein in Spermatogenesis

    Get PDF
    BACKGROUND: Heat shock severely affects sperm production (spermatogenesis) and results in a rapid loss of haploid germ cells, or in other words, sperm formation (spermiogenesis) is inhibited. However, the mechanisms behind the effects of heat shock on spermatogenesis are obscure. METHODOLOGY/PRINCIPAL FINDINGS: To identify the inhibitory factor of spermiogenesis, experimental cryptorchid (EC) mice were used in this study. Here we show that α-fetoprotein (AFP) is specifically expressed in the testes of EC mice by proteome analysis. AFP was also specifically localized spermatocytes by immunohistochemical analysis and was secreted into the circulation system of EC mice by immunoblot analysis. Since spermatogenesis of an advanced mammal cannot be reproduced with in vitro, we performed the microinjection of AFP into the seminiferous tubules of normal mice to determine whether AFP inhibits spermiogenesis in vivo. AFP was directly responsible for the block in spermiogenesis of normal mice. To investigate whether AFP inhibits cell differentiation in other models, using EC mice we performed a partial hepatectomy (PH) that triggers a rapid regenerative response in the remnant liver tissue. We also found that liver regeneration is inhibited in EC mice with PH. The result suggests that AFP released into the blood of EC mice regulates liver regeneration by inhibiting the cell division of hepatocytes. CONCLUSIONS/SIGNIFICANCE: AFP is a well-known cancer-specific marker, but AFP has no known function in healthy human beings. Our findings indicate that AFP expressed under EC conditions plays a role as a regulatory factor in spermatogenesis and in hepatic generation

    Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector

    Get PDF
    In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown. © CERN 2016

    Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Get PDF
    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC.This project is at the final stages of R&D and moving to production. A large area of several 100 m 2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector.The quality control steps will include optical inspection,cleaning and baking of all materials and parts used to build the detector,leakage current tests of the GEM foils,high voltage tests,gas leak tests of the chambers and monitoring pressures time,gain calibration to know the optimal operation region of the detector,gain uniformity tests, and studying the efficiency,noise and tracking performance of the detectors in a cosmic stand using scintillator
    • 

    corecore