10 research outputs found

    Circadian rhythm of cardiac troponin I and its clinical impact on the diagnostic accuracy for acute myocardial infarction

    Get PDF
    High-sensitivity cardiac troponin T (hs-cTnT) blood concentrations were shown to exhibit a diurnal rhythm, characterized by gradually decreasing concentrations throughout daytime, rising concentrations during nighttime and peak concentrations in the morning. We aimed to investigate whether this also applies to (h)s-cTnI assays and whether it would affect diagnostic accuracy for acute myocardial infarction (AMI).; Blood concentrations of cTnI were measured at presentation and after 1 h using four different cTnI assays: three commonly used sensitive (s-cTnI Architect, Ultra and Accu) and one experimental high-sensitivity assay (hs-cTnI Accu) in a prospective multicenter diagnostic study of patients presenting to the emergency department with suspected AMI. These concentrations and their diagnostic accuracy for AMI (quantified by the area under the curve (AUC)) were compared between morning (11 p.m. to 2 p.m.) and evening (2 p.m. to 11 p.m.) presenters.; Among 2601 patients, AMI was the final diagnosis in 17.6% of patients. Concentrations of (h)s-cTnI as measured using all four assays were comparable in patients presenting in the morning versus patients presenting in the evening. Diagnostic accuracy for AMI of all four (h)s-cTnI assays were high and comparable between patients presenting in the morning versus presenting in the evening (AUC at presentation: 0.90 vs 0.93 for s-cTnI Architect; 0.91 vs 0.94 for s-cTnI Ultra; 0.89 vs 0.94 for s-cTnI Accu; 0.91 vs 0.94 for hs-cTnI Accu).; Cardiac TnI does not seem to express a diurnal rhythm. Diagnostic accuracy for AMI is very high and does not differ with time of presentation.; NCT00470587, http://clinicaltrials.gov/show/NCT00470587

    Landslides Triggered by the MW 7.8 14 November 2016 Kaikoura Earthquake, New Zealand

    Get PDF
    The MW 7.8 14 November 2016 Kaikoura earthquake generated more than 10000 landslides over a total area of about 10000 km2, with the majority concentrated in a smaller area of about 3600 km2. The largest landslide triggered by the earthquake had an approximate volume of 20 (±2) M m3, with a runout distance of about 2.7 km, forming a dam on the Hapuku River. In this paper, we present version 1.0 of the landslide inventory we have created for this event. We use the inventory presented in this paper to identify and discuss some of the controls on the spatial distribution of landslides triggered by the Kaikoura earthquake. Our main findings are (1) the number of medium to large landslides (source area ≥10000 m2) triggered by the Kaikoura earthquake is smaller than for similar sized landslides triggered by similar magnitude earthquakes in New Zealand; (2) seven of the largest eight landslides (from 5 to 20 x 106 m3) occurred on faults that ruptured to the surface during the earthquake; (3) the average landslide density within 200 m of a mapped surface fault rupture is three times that at a distance of 2500 m or more from a mapped surface fault rupture ; (4) the “distance to fault” predictor variable, when used as a proxy for ground-motion intensity, and when combined with slope angle, geology and elevation variables, has more power in predicting landslide probability than the modelled peak ground acceleration or peak ground velocity; and (5) for the same slope angles, the coastal slopes have landslide point densities that are an order of magnitude greater than those in similar materials on the inland slopes, but their source areas are significantly smaller

    Tabes

    No full text
    corecore