400 research outputs found

    Measuring attitude toward theistic faith : assessing the Astley-Francis Scale among Christian, Muslim and secular youth in England

    Get PDF
    Empirical research within the social scientific study of religion in general and within the psychology of religion in particular remains very conscious of the complex nature of its subject matter. Empirical research in this field needs to take cognisance of the many forms in which religion is expressed (say, Buddhism, Christianity, Hinduism, Islam, Judaism, and Sikhism) and the many facets within the forms (say, beliefs, behaviours and affiliation). Working in the 1970s, Francis (1978a; 1978b) advanced the view that the attitudinal dimension of religion offered a particularly fruitful basis for coordinating empirical enquiry into the correlates, antecedents and consequences of religiosity across the life span

    Radioimmunotherapy Improves Survival of Rats with Microscopic Liver Metastases of Colorectal Origin

    Get PDF
    BACKGROUND: Half of the patients with colorectal cancer develop liver metastases during the course of their disease. The aim of the present study was to assess the efficacy of radioimmunotherapy (RIT) with a radiolabeled monoclonal antibody (mAb) to treat experimental colorectal liver metastases. METHODS: Male Wag/Rij rats underwent a minilaparotomy with intraportal injection of 1 x 10(6) CC531 tumor cells. The biodistribution of (111)In-labeled MG1, 1 day after intravenous administration, was determined in vivo and compared with that of an isotype-matched control antibody (UPC-10). The maximal tolerated dose (MTD) of (177)Lu-labeled MG1 was determined and the therapeutic efficacy of (177)Lu-MG1 at MTD was compared with that of (177)Lu-UPC-10 and saline only. RIT was administered either at the day of tumor inoculation or 14 days after tumor inoculation. Primary endpoint was survival. RESULTS: (111)In-MG1 preferentially accumulated in CC531 liver tumors (9.2 +/- 3.7%ID/g), whereas (111)In-UPC-10 did not (0.8 +/- 0.1%ID/g). The MTD of (177)Lu-MG1 was 400 MBq/kg body weight. Both the administration of (177)Lu-MG1 and (177)Lu-UPC-10 had no side-effects except a transient decrease in body weight. The survival curves of the group that received (177)Lu-UPC-10 and the group that received saline only did not differ (P = 0.407). Administration of (177)Lu-MG1 RIT immediately after surgery improved survival significantly compared with administration of (177)Lu-UPC-10 (P = 0.009) whereas delayed treatment did not (P = 0.940). CONCLUSION: This study provides proof of principle that RIT can be an effective treatment modality for microscopic liver metastases, whereas RIT is not effective in larger tumors

    Renal uptake of different radiolabelled peptides is mediated by megalin: SPECT and biodistribution studies in megalin-deficient mice

    Get PDF
    Contains fulltext : 98302.pdf (publisher's version ) (Closed access)PURPOSE: Radiolabelled peptides used for peptide receptor radionuclide therapy are excreted mainly via the kidneys and are partly reabsorbed and retained in the proximal tubular cells. The resulting high renal radiation dose can cause nephrotoxicity, limiting the maximum activity dose and the effectiveness of peptide receptor radionuclide therapy. The mechanisms of kidney reabsorption of these peptides are incompletely understood, but the scavenger receptor megalin has been shown to play a role in the reabsorption of (111)In-octreotide. In this study, the role of megalin in the renal reabsorption of various relevant radiolabelled peptides was investigated. METHODS: Groups of kidney-specific megalin-deficient mice and wild-type mice were injected with (111)In-labelled somatostatin, exendin, neurotensin or minigastrin analogues. Single photon emission computed tomographic (SPECT) images of the kidneys were acquired and analysed quantitatively, or the animals were killed 3 h after injection and the activity concentration in the kidneys was measured. RESULTS: Megalin-deficient mice showed significantly lower uptake of all studied radiolabelled peptides in the kidneys, ranging from 22% ((111)In-octreotide) to 65% ((111)In-exendin) of uptake in wild-type kidneys. Quantitative analysis of renal uptake by SPECT and ex vivo measurements showed a very good correlation. CONCLUSION: Megalin is involved in the renal reabsorption of radiolabelled octreotide, octreotate, exendin, neurotensin and minigastrin. This knowledge may help in the design of strategies to reduce this reabsorption and the resulting nephrotoxicity in peptide receptor radionuclide therapy, enabling more effective therapy. Small-animal SPECT is an accurate tool, allowing in vivo quantification of renal uptake and serial measurements in individual mice

    Durable response with single-agent acalabrutinib in patients with relapsed or refractory mantle cell lymphoma

    Get PDF
    Bruton tyrosine kinase (BTK) inhibitors have greatly improved the spectrum of treatment options in mantle cell lymphoma (MCL) [1–4]. Acalabrutinib is a highly selective, orally administered, and potent BTK inhibitor with limited off-target activity [5]. Acalabrutinib was approved in 2017 by the US Food and Drug Administration for the treatment of relapsed/refractory MCL based on clinical data from the open-label, multicenter, phase 2 ACE-LY-004 study of acalabrutinib 100 mg twice daily [1]. Here, we present updated results from the ACE-LY-004 study after a median 26-month follow-up. Eligibility criteria and study design were published previously (Supplementary methods) [1]. Analysis of minimal residual disease (MRD) was conducted after complete response (CR) or partial response (PR) was achieved using the quantitative ClonoSEQ next-generation sequencing (5 × 10−6 ) assay (Adpative Biotechnologies, Seattle, WA, USA) in consenting patients with available paired archival tumor and whole blood samples. Data are updated as of February 12, 2018

    Albumin-derived peptides efficiently reduce renal uptake of radiolabelled peptides

    Get PDF
    Contains fulltext : 88022.pdf (publisher's version ) (Closed access)PURPOSE: In peptide-receptor radionuclide therapy (PRRT), the maximum activity dose that can safely be administered is limited by high renal uptake and retention of radiolabelled peptides. The kidney radiation dose can be reduced by coinfusion of agents that competitively inhibit the reabsorption of radiolabelled peptides, such as positively charged amino acids, Gelofusine, or trypsinised albumin. The aim of this study was to identify more specific and potent inhibitors of the kidney reabsorption of radiolabelled peptides, based on albumin. METHODS: Albumin was fragmented using cyanogen bromide and six albumin-derived peptides with different numbers of electric charges were selected and synthesised. The effect of albumin fragments (FRALB-C) and selected albumin-derived peptides on the internalisation of (111)In-albumin, (111)In-minigastrin, (111)In-exendin and (111)In-octreotide by megalin-expressing cells was assessed. In rats, the effect of Gelofusine and albumin-derived peptides on the renal uptake and biodistribution of (111)In-minigastrin, (111)In-exendin and (111)In-octreotide was determined. RESULTS: FRALB-C significantly reduced the uptake of all radiolabelled peptides in vitro. The albumin-derived peptides showed different potencies in reducing the uptake of (111)In-albumin, (111)In-exendin and (111)In-minigastrin in vitro. The most efficient albumin-derived peptide (peptide #6), was selected for in vivo testing. In rats, 5 mg of peptide #6 very efficiently inhibited the renal uptake of (111)In-minigastrin, by 88%. Uptake of (111)In-exendin and (111)In-octreotide was reduced by 26 and 33%, respectively. CONCLUSIONS: The albumin-derived peptide #6 efficiently inhibited the renal reabsorption of (111)In-minigastrin, (111)In-exendin and (111)In-octreotide and is a promising candidate for kidney protection in PRRT.1 februari 201

    Effectiveness of behavioural graded activity compared with physiotherapy treatment in chronic neck pain: design of a randomised clinical trial [ISRCTN88733332]

    Get PDF
    BACKGROUND: Chronic neck pain is a common complaint in the Netherlands with a point prevalence of 14.3%. Patients with chronic neck pain are often referred to a physiotherapist and, although many treatments are available, it remains unclear which type of treatment is to be preferred. The objective of this article is to present the design of a randomised clinical trial, Ephysion, which examines the clinical and cost effectiveness of behavioural graded activity compared with a physiotherapy treatment for patients with chronic non-specific neck pain. METHODS: Eligible patients with non-specific neck pain persisting longer than 3 months will be randomly allocated to either the behavioural graded activity programme or to the physiotherapy treatment. The graded activity programme is based on an operant approach, which uses a time-contingent method to increase the patient's activity level. This treatment is compared with physiotherapy treatment using a pain-contingent method. Primary treatment outcome is the patient's global perceived effect concerning recovery from the complaint. Global perceived effect on daily functioning is also explored as primary outcome to establish the impact of treatment on daily activity. Direct and indirect costs will also be assessed. Secondary outcomes include the patient's main complaints, pain intensity, medical consumption, functional status, quality of life, and psychological variables. Recruitment of patients will take place up to the end of the year 2004 and follow-up measurement will continue until end 2005

    Construction and test of a fine-grained liquid argon preshower prototype

    Get PDF
    A separate liquid argon preshower detector consisting of two layers featuring a fine granularity of 2.5~103^{\mathrm{-3}} was studied by the RD3 collaboration. A prototype covering approximately 0.8 in pseudo-rapidity and 9 degrees in azimuth was built and tested at CERN in July 94. CMOS and GaAs VLSI preamplifiers were designed and tested for this occasion. The combined response of this detector and an accordion electromagnetic calorimeter prototype to muons, electrons and photons is presented. For minimum ionizing tracks a signal-to-noise ratio of 4.5 per preshower layer was measured. Above 150~GeV the space resolution for electrons is better than 250~μ\mum in both directions. The precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 4 mrad above 50~GeV. It is concluded that the preshower detector would adequately fulfil its role for future operation at CERN Large Hadron Collider
    corecore