642 research outputs found

    Semisolid processing characteristics of AM series Mg alloys by rheo-diecasting

    Get PDF
    The official published version of this Article can be found at the link below - Copyright @ 2006 ASM InternationalAn investigation has been made into the solidification behavior and microstructural evolution of AM50, AM70, and AM90 alloys during rheo-diecasting, their processibility, and the resulting mechanical properties. It was found that solidification of AM series alloys under intensive melt shearing in the unique twin-screw slurry maker during rheo-diecasting gave rise to numerous spheroidal primary magnesium (Mg) particles that were uniformly present in the microstructure. As a result, the network of the beta-Mg17Al12 phase was consistently interrupted by these spheroidal and ductile particles. Such a microstructure reduced the obstacle of deformation and the harmfulness of the beta-Mg17Al12 network on ductility, and therefore improved the ductility of rheo-diecast AM alloys. It was shown that, even with 9 wt pct Al, the elongation of rheo-diecast AM90 still achieved (9 +/- 1.2) pct. Rheodiecasting thus provides an attractive processing route for upgrading the alloy specification of AM series alloys by increasing the aluminum (Al) content while ensuring ductility. Assessment of the processibility of AM series alloys for semisolid processing showed that high Al content AM series alloys are more suitable for rheo-diecasting than low Al content alloys, because of the lower sensitivity of solid fraction to temperature, the lower liquidus temperature, and the smaller interval between the semisolid processing temperature and the complete solidification temperature.This work is supported by the EPSR

    Continuous twin screw rheo-extrusion of an AZ91D magnesium alloy

    Get PDF
    © The Minerals, Metals & Materials Society and ASM International 2012The twin screw rheo-extrusion (TSRE) is designed to take advantage of the nondendritc microstructure and thixotropic characterization of semisolid-metal slurries and produce simple metal profiles directly from melts. The extrusion equipment consists of a rotor-stator high shear slurry maker, a twin screw extruder, and a die assembly. The process is continuous and has a potential for significantly saving energy, manufacturing cost, and enhancing efficiency. The present investigation was carried out to study the process performance for processing rods of an AZ91D magnesium alloy and the microstructure evolution during processing. The semisolid slurry prepared by the process was characterized by uniformly distributed nondendritic granular primary phase particles. AZ91D rods with uniform and fine microstructures and moderate mechanical properties were produced. For the given slurry making parameters, decreasing extrusion temperature was found to improve microstructures and properties. The mechanisms of particle granulation and refinement and the effect of processing parameters on process performance and thermal management are discussed. © 2012 The Minerals, Metals & Materials Society and ASM International.EPSRC (UK) and Rautomead Lt

    Intensity-Based Registration of Freehand 3D Ultrasound and CT-scan Images of the Kidney

    Full text link
    This paper presents a method to register a pre-operative Computed-Tomography (CT) volume to a sparse set of intra-operative Ultra-Sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 Degree Of Freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images have been preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, Correlation Ratio (CR) turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent's. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. The obtained results are presented and discussed

    Coupling undetected sensing modes by quantum erasure

    Full text link
    The effect known as ``induced coherence without induced emission'' has spawned a field dedicated to imaging with undetected photons (IUP), where photons from two distinct photon-pair sources interfere if their outputs are made indistinguishable. The indistinguishability is commonly achieved in two setups. Induced coherence IUP (IC-IUP) has only the idler photons from the first source passing through the second, whilst nonlinear interferometry (NI-IUP) has both signal and idler photons from the first source passing through the second and can be simpler to implement. In both cases, changes in the idler path between sources can be detected by measuring the interference fringes in the signal path in a way that allows image information to be moved between different wavelengths. Here we model and implement a novel setup that uses a polarization state quantum eraser approach to move continuously between IC-IUP and NI-IUP operation. We find excellent agreement between experiment and theory in the low-gain or quantum regime. The system also provides a new route for optimizing IUP interference by using controllable quantum erasure to balance the interferometer

    Precision measurement of σ(e+eπ+πγ)/σ(e+eμ+μγ)\sigma(e^+e^-\rightarrow\pi^+\pi^-\gamma)/\sigma(e^+e^-\rightarrow \mu^+\mu^-\gamma) and determination of the π+π\pi^+\pi^- contribution to the muon anomaly with the KLOE detector

    Full text link
    We have measured the ratio σ(e+eπ+πγ)/σ(e+eμ+μγ)\sigma(e^+e^-\rightarrow\pi^+\pi^-\gamma)/\sigma(e^+e^-\rightarrow \mu^+\mu^-\gamma), with the KLOE detector at DAΦ\PhiNE for a total integrated luminosity of \sim 240 pb1^{-1}. From this ratio we obtain the cross section σ(e+eπ+π)\sigma(e^+e^-\rightarrow\pi^+\pi^-). From the cross section we determine the pion form factor Fπ2|F_\pi|^2 and the two-pion contribution to the muon anomaly aμa_\mu for 0.592<Mππ<0.9750.592<M_{\pi\pi}<0.975 GeV, Δππaμ\Delta^{\pi\pi} a_\mu= (385.1±1.1stat±2.7sys+theo)×1010({\rm 385.1\pm1.1_{stat}\pm2.7_{sys+theo}})\times10^{-10}. This result confirms the current discrepancy between the Standard Model calculation and the experimental measurement of the muon anomaly.Comment: 18 pages, 8 figures, minor text corrections, one table added, version to appear on Physics Letters

    Limit on the production of a new vector boson in e+eUγ\mathrm{e^+ e^-}\rightarrow {\rm U}\gamma, Uπ+π\rightarrow \pi^+\pi^- with the KLOE experiment

    Get PDF
    The recent interest in a light gauge boson in the framework of an extra U(1) symmetry motivates searches in the mass range below 1 GeV. We present a search for such a particle, the dark photon, in e+eUγ{\rm e^+ e^-}\rightarrow {\rm U}\gamma, Uπ+π\rightarrow \pi^+\pi^- based on 28 million e+eπ+πγ\mathrm{e^+ e^-} \rightarrow \pi^+ \pi^-\gamma events collected at DAΦ\PhiNE by the KLOE experiment. The π+π\pi^+ \pi^- production by initial-state radiation compensates for a loss of sensitivity of previous KLOE Ue+e{\rm U} \rightarrow \mathrm{e^+ e^-}, μ+μ\mu^+\mu^- searches due to the small branching ratios in the ρω\rho-\omega resonance region. We found no evidence for a signal and set a limit at 90\% CL on the mixing strength between the photon and the dark photon, ε2\varepsilon^2, in the U mass range between 527527 and 987987~MeV. Above 700 MeV this new limit is more stringent than previous ones.Comment: 6 pages, 9 figures, 1 table, submitted to Phys. Lett.

    Measurement of {\eta} meson production in {\gamma}{\gamma} interactions and {\Gamma}({\eta}-->{\gamma}{\gamma}) with the KLOE detector

    Get PDF
    We present a measurement of {\eta} meson production in photon-photon interactions produced by electron-positron beams colliding with \sqrt{s}=1 GeV. The measurement is done with the KLOE detector at the \phi-factory DA{\Phi}NE with an integrated luminosity of 0.24 fb^{-1}. The e^+e^- --> e^+e^-{\eta} cross section is measured without detecting the outgoing electron and positron, selecting the decays {\eta}-->{\pi}^+{\pi}^-{\pi}^0 and {\eta}-->{\pi}^0{\pi}^0{\pi}^0. The most relevant background is due to e^+e^- --> {\eta}{\gamma} when the monochromatic photon escapes detection. The cross section for this process is measured as {\sigma}(e^+e^- -->{\eta}{\gamma}) = (856 \pm 8_{stat} \pm 16_{syst}) pb. The combined result for the e^+e^- -->e^+e^-{\eta} cross section is {\sigma}(e^+e^- -->e^+e^-{\eta}) = (32.72 \pm 1.27_{stat} \pm 0.70_{syst}) pb. From this we derive the partial width {\Gamma}({\eta}-->{\gamma}{\gamma}) = (520 \pm 20_{stat} \pm 13_{syst}) eV. This is in agreement with the world average and is the most precise measurement to date.Comment: Version accepted by JHE
    corecore