270 research outputs found

    Concentrated Differential Privacy: Simplifications, Extensions, and Lower Bounds

    Get PDF
    "Concentrated differential privacy" was recently introduced by Dwork and Rothblum as a relaxation of differential privacy, which permits sharper analyses of many privacy-preserving computations. We present an alternative formulation of the concept of concentrated differential privacy in terms of the Renyi divergence between the distributions obtained by running an algorithm on neighboring inputs. With this reformulation in hand, we prove sharper quantitative results, establish lower bounds, and raise a few new questions. We also unify this approach with approximate differential privacy by giving an appropriate definition of "approximate concentrated differential privacy.

    Quantum entanglement distribution with 810 nm photons through telecom fibers

    Full text link
    We demonstrate the distribution of polarization entangled photons of wavelength 810 nm through standard telecom fibers. This technique allows quantum communication protocols to be performed over established fiber infrastructure, and makes use of the smaller and better performing setups available around 800 nm, as compared to those which use telecom wavelengths around 1550 nm. We examine the excitation and subsequent quenching of higher-order spatial modes in telecom fibers up to 6 km in length, and perform a distribution of high quality entanglement (visibility 95.6%). Finally, we demonstrate quantum key distribution using entangled 810 nm photons over a 4.4 km long installed telecom fiber link.Comment: 5 pages, 5 figures, 1 tabl

    Integration of data from remote monitoring systems and programmers into the hospital electronic health record system based on international standards

    Get PDF
    Remote follow-up of implanted ICDs may offer a solution to the problem of overcrowded outpatient clinics. All major device companies have developed a remote follow-up solution. Data obtained from the remote follow-up systems are stored in a central database system, operated and owned by the device company and accessible for the physician or technician. However, the problem now arises that part of the patient’s clinical information is stored in the local electronic health record (EHR) system in the hospital, while another part is only available in the remote monitoring database. This may potentially result in patient safety issues. Ideally all information should become available in the EHR system. IHE (Integrating the Healthcare Enterprise) is an initiative to improve the way computer systems in healthcare share information. To address the requirement of integrating remote monitoring data in the local EHR, the IHE Implantable Device Cardiac Observation (IDCO) profile has been developed. In our hospital, we have implemented the IHE IDCO profile to import data from the remote databases from two device vendors into the departmental Cardiology Information System. Data are exchanged via an HL7/XML communication protocol, as defined in the IHE IDCO profile

    Studying Free-Space Transmission Statistics and Improving Free-Space QKD in the Turbulent Atmosphere

    Full text link
    The statistical fluctuations in free-space links in the turbulent atmosphere are important for the distribution of quantum signals. To that end, we first study statistics generated by the turbulent atmosphere in an entanglement based free-space quantum key distribution (QKD) system. Using the insights gained from this analysis, we study the effect of link fluctuations on the security and key generation rate of decoy state QKD concluding that it has minimal effect in the typical operating regimes. We then investigate the novel idea of using these turbulent fluctuations to our advantage in QKD experiments. We implement a signal-to-noise ratio filter (SNRF) in our QKD system which rejects measurements during periods of low transmission efficiency, where the measured quantum bit error rate (QBER) is temporarily elevated. Using this, we increase the total secret key generated by the system from 78,009 bits to 97,678 bits, representing an increase of 25.2% in the final secure key rate, generated from the same raw signals. Lastly, we present simulations of a QKD exchange with an orbiting LEO satellite and show that an SNRF will be extremely useful in such a situation, allowing many more passes to extract a secret key than would otherwise be possible.Comment: 9 pages, 6 figure

    Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients

    Get PDF
    ObjectivesThis study aimed to assess the prevalence of different types of atrial fibrillation (AF) and their prognostic importance in implantable cardioverter-defibrillator (ICD) patients.BackgroundThe prevalence of AF has taken epidemic proportions in the population with cardiovascular disease. The prognostic importance of different types of AF in ICD patients remains unclear.MethodsData on 913 consecutive patients (79% men, mean age 62 ± 13 years) receiving an ICD at the Leiden University Medical Center were prospectively collected. Among other characteristics, the existence and type of AF (paroxysmal, persistent, or permanent) were assessed at implantation. During follow-up, the occurrence of appropriate or inappropriate device therapy as well as mortality was noted.ResultsAt implantation, 73% of patients had no history of AF, 9% had a history of paroxysmal AF, 7% had a history of persistent AF, and 11% had permanent AF. During 833 ± 394 days of follow-up, 117 (13%) patients died, 228 (25%) patients experienced appropriate device discharge, and 139 (15%) patients received inappropriate shocks. Patients with permanent AF exhibited more than double the risk of mortality, ventricular arrhythmias triggering device discharge, and inappropriate device therapy. Patients with paroxysmal or persistent AF did not show a significant increased risk of mortality or appropriate device therapy but demonstrated almost 3 times the risk of inappropriate device therapy.ConclusionsIn the population currently receiving ICD treatment outside the setting of clinical trials, a large portion has either a history of AF or permanent AF. Both types of AF have prognostic implications for mortality and appropriate as well as inappropriate device discharge

    Highly crystallized as-grown smooth and superconducting MgB2 films by molecular-beam epitaxy

    Get PDF
    We have investigated the growth of superconductive thin films of magnesium diboride (MgB2) by molecular-beam epitaxy. A Si(111) substrate with a seed layer of MgO was used for the growth of these films by varying parameters such as the growth temperature, Mg:B flux ratio and deposition rate as well as the background pressure. It was found that highly crystallized films could already form at 250 °C; however, only in a narrow window of growth parameters. The highest critical temperature of 35.2 K with a sharp transition (TC of 0.5 K) was observed for films grown at 300 °C. Using a capping layer of MgO proved to be highly beneficial for the preservation and the smoothness of these films. Together with the fact that MgO proved to be a good seed layer for thin films of MgB2 makes it an ideal candidate for growing all epitaxial MgB2 Josephson junctions. ©2002 American Institute of Physics

    Examination of the production of an isotensor dibaryon in the pp → ppπ+π− reaction

    Get PDF
    Exclusive measurements of the quasi-free ppopppi+pipp o pppi^+pi^- reaction have been performed by means of pdpd collisions at TpT_p = 1.2 GeV using the WASA detector setup at COSY. Total and differential cross sections have been obtained covering the energy region Tp=1.081.36T_p = 1.08 - 1.36 GeV (sqrtssqrt s = 2.35 - 2.46 GeV), which includes the regions of N(1440)N^*(1440) and Delta(1232)Delta(1232)Delta(1232)Delta(1232) resonance excitations. Calculations describing these excitations by tt-channel meson exchange are at variance with experimental differential cross sections and underpredict substantially the measured total cross section. An isotensor DeltaNDelta N dibaryon resonance with I(JP)=2(1+)I(J^P) = 2(1^+) produced associatedly with a pion is able to overcome these deficiencies. Such a dibaryon was predicted by Dyson and Xuong and more recently calculated by Gal and Garcilazo

    Search for eta-mesic 4He in the dd->3He n pi0 and dd->3He p pi- reactions with the WASA-at-COSY facility

    Full text link
    The search for 4He-eta bound states was performed with the WASA-at-COSY facility via the measurement of the excitation function for the dd->3He n pi0 and dd->3He p pi- processes. The beam momentum was varied continuously between 2.127 GeV/c and 2.422 GeV/c, corresponding to the excess energy for the dd->4He eta reaction ranging from Q=-70 MeV to Q=30 MeV. The luminosity was determined based on the dd->3He n reaction and quasi-free proton-proton scattering via dd->pp n_spectator n_spectator reactions. The excitation functions determined independently for the measured reactions do not reveal a structure which could be interpreted as a narrow mesic nucleus. Therefore, the upper limits of the total cross sections for the bound state production and decay in dd->(4He-eta)_bound->3He n pi0 and dd->(4He-eta)_bound->3He p pi- processes were determined taking into account the isospin relation between both the channels considered. The results of the analysis depend on the assumptions of the N* momentum distribution in the anticipated mesic-4He. Assuming as in the previous works, that this is identical with the distribution of nucleons bound with 20 MeV in 4He, we determined that (for the mesic bound state width in the range from 5 MeV to 50 MeV) the upper limits at 90% confidence level are about 3 nb and about 6 nb for npi0 and ppi- channels, respectively. However, based on the recent theoretical findings of the N*(1535) momentum distribution in the N*-3He nucleus bound by 3.6 MeV, we find that the WASA-at-COSY detector acceptance decreases and hence the corresponding upper limits are 5 nb and 10 nb for npi0 and ppi- channels respectively.Comment: This article will be submitted to JHE
    corecore