265 research outputs found
Fas induces apoptosis in human coronary artery endothelial cells in vitro
BACKGROUND: Published work suggests that some types of endothelial cells undergo apoptosis in response to ligation of the receptor Fas (CD95, APO1) but other types are resistant. Because heterogeneity among endothelial cells from different tissues, has been demonstrated, the purpose of this study was to determine, if Fas ligation and/or activation by human Fas ligand induces apoptosis and caspase activities, in cultured human coronary artery endothelial cells, and the differences between TNF-a and FAS induced apoptosis in these cells. RESULTS: Cultured human coronary artery endothelial cells (HCAEC) were exposed to the monoclonal Fas-activating antibody CH-11, to purified recombinant human Fas ligand, to the Fas-neutralizing antibody ZB4, or to purified recombinant human TNF-α. Apoptosis was detected by assessment of chromatin condensation and nuclear fragmentation and by assay of the enzymatic activities of Caspase 1 and Caspase 3 with membrane-permeable substrates applied to intact cells. Fas protein was detected by immunoblotting of HCAEC lysates. Apoptosis was induced in HCAEC by purified Fas ligand or by the monoclonal activating antibody CH-11 at concentrations of 25 or 200 ng/ml, but not by nonspecific isotype-matched immunoglobulins. The apoptotic index elicited by either Fas activator was equal to that induced by TNF-a (3.0-3.6-fold versus control, p < 0.01). The Fas-neutralizing antibody ZB4 abrogated HCAEC apoptosis induced by CH-11, but had no inhibitory effect on apoptosis in response to TNF-a. Fas ligation significantly increased the activities of both Caspase 1 and Caspase 3 at 20 hours of stimulation (1.7- and 2.0-fold versus control, both p < 0.05); in contrast, purified TNF-a increased the activity of Caspase 3 but not Caspase 1 (2.1-fold, p < 0.05). Western blotting of HCAEC lysates with antibody CH-11 identified a single immunoreactive protein of 90 kDa. CONCLUSIONS: Cultured human coronary artery endothelial cells express functional Fas capable of inducing apoptosis in response to either purified Fas ligand or receptor-activating monoclonal antibodies, at levels equal to those inducible by purified TNF-α. Immunologic studies and differential kinetics of caspase activation suggest that Fas and TNF-α induce apoptosis in HCAEC by signaling pathways that are distinct but equal in potency
Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries
Abstract
Background
Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres.
Methods
This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries.
Results
In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia.
Conclusion
This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries
Working environment-related leisure time satisfaction levels and health behaviors of university office workers and ergonomic solutions
The present study aims to investigate the health behaviors of university office workers related to the working environment, compare them with leisure time satisfaction, and suggest ergonomic solutions. Office workers at Bitlis Eren University and Munzur University, which are situated in the eastern part of Turkey, constituted the population of this study. The sample size was 196 based on the formula [n = (N*t2*p*q)/d2*(N-1)+t2*p*q)], which was applied when the number of people in the population was known. The required sample size was determined based on the estimation of a proportion of 0.5 in a finite population of 401, with a 95% confidence interval of ± 0.05 using simple random sampling. The data of Questionnaire and Leisure Satisfaction Scale (LSS) were collected from 178 participants by a face-to-face interview voluntarily. The findings obtained in this study showed that nearly half of the participants did not sufficiently support their wrists and backs and did not adjust their working posture or the screen inclination and brightness. The mean score of leisure time satisfaction was higher for those who worked in places with ideal physical conditions, including heat and sound insulation and in places with good psychological conditions without stress and work overload. The leisure time satisfaction score was significantly higher among those who engaged in leisure time activities, such as recreational activities reading books, and physical activity. It was observed that employees in offices with improved noise, heat, workload and stress had better satisfaction levels in leisure time. One cannot separate leisure activities from workplace activities and both should be conducted in harmony. As an ergonomic solution, the worktable and tools should be comfortable and designed in a way that does not require the back muscles to be strained. [Med-Science 2022; 11(2.000): 814-9
Propionibacterium acnes Causing Mediastinal Infection following Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is now a standard of care to sample mediastinal lymph nodes and masses with high diagnostic accuracy and low complication rates. However, the procedure has potential complications that might be life-threatening. Here, we present the first case of Propionobacterium acnes (P. acnes) causing mediastinitis following EBUS-TBNA of a subcarinal lymph node
Chyloptysis causing plastic bronchitis
Chyloptysis is a rare clinical problem that is associated with conditions affecting lymphatic channels in the thorax. Diagnosis is usually made when the patients present with expectoration of milky-white sputum or of thick tenacious mucus in the shape of smaller bronchi (bronchial cast). Typically the symptoms resolve after coughing up of the bronchial casts. Pleural, mediastinal, pulmonary or lymphatic abnormalities result in chyloptysis. Lymphangiography and detection of lipids (cholesterol or triglycerides) in sputum help to establish the diagnosis. However, lymphangiography may not be positive in all patients. We report 2 patients with chyloptysis and bronchial casts with different etiologies. Abnormal lymphatics were demonstrated in one of our cases, but the second patients lymphangiogram was normal. In this patient we suspect that high venous filling pressures due to congestive heart failure had a causative effect in the setting of compromised lymphatic drainage in the thorax due to a prior history of radiation therapy to the chest for lymphoma
Cross-cultural adaptation and validation of Diabetes Quality of Life Brief Clinical Inventory in Turkish patients with type 2 diabetes mellitus
PurposeTo translate and culturally adapt the Diabetes Quality of Life Brief Clinical Inventory (DQoL-BCI) into Turkish and assess the psychometric properties of the translated version.MethodsA forward-backward translation process was conducted in conformity with international guidelines. A total of 150 patients with type 2 diabetes mellitus (T2DM) completed the Turkish version of DQoL-BCI (DQoL-BCI-Tr). The factor structure, test-retest reliability, and construct validity were evaluated.ResultsIn the DQoL-BCI-Tr, the three-factor structure was found optimal and explained 68.7% of the variance. The DQoL-BCI-Tr showed excellent internal consistency (Cronbach's alpha = 0.90) and test-retest reliability (ICC = 0.98). Cronbach's alpha values ranged from 0.85 to 0.91 for subscales (satisfaction, worry, impact). A negative correlation was found between the total scores of the DQoL-BCI-Tr and the EuroQoL-5 dimensions (EQ-5D) indexes (r= -0.22, p 9%) and the use of insulin.ConclusionsThe study results showed that the DQoL-BCI-Tr can be served as a reliable and valid instrument to obtain information from Turkish patients with T2DM diagnosis, including satisfaction with treatment, the impact of the disease, and worry about the social/vocational issues
Intrabronchial Valve Treatment for Prolonged Air Leak: Can We Justify the Cost?
Background. Prolonged air leak is defined as an ongoing air leak for more than 5 days. Intrabronchial valve (IBV) treatment is approved for the treatment of air leaks. Objective. To analyze our experience with IBV and valuate its cost-effectiveness. Methods. Retrospective analysis of IBV from June 2013 to October 2014. We analyzed direct costs based on hospital and operating room charges. We used average costs in US dollars for the analysis not individual patient data. Results. We treated 13 patients (9 M/4 F), median age of 60 years (38 to 90). Median time from diagnosis to IBV placement was 9.8 days, time from IBV placement to chest tube removal was 3 days, and time from IBV placement to hospital discharge was 4 days. Average room and board costs were 2750 per valve. The average number of valves used was 4. Total cost of procedure, valves, and hospital stay until discharge was $13,900. Conclusion. In our limited experience, the use of IBV to treat prolonged air leaks is safe and appears cost-effective. In pure financial terms, the cost seems justified for any air leak predicted to last greater than 8 days
Intrabronchial Valve Treatment for Prolonged Air Leak: Can We Justify the Cost?
Background. Prolonged air leak is defined as an ongoing air leak for more than 5 days. Intrabronchial valve (IBV) treatment is approved for the treatment of air leaks. Objective. To analyze our experience with IBV and valuate its cost-effectiveness. Methods. Retrospective analysis of IBV from June 2013 to October 2014. We analyzed direct costs based on hospital and operating room charges. We used average costs in US dollars for the analysis not individual patient data. Results. We treated 13 patients (9 M/4 F), median age of 60 years (38 to 90). Median time from diagnosis to IBV placement was 9.8 days, time from IBV placement to chest tube removal was 3 days, and time from IBV placement to hospital discharge was 4 days. Average room and board costs were 2750 per valve. The average number of valves used was 4. Total cost of procedure, valves, and hospital stay until discharge was $13,900. Conclusion. In our limited experience, the use of IBV to treat prolonged air leaks is safe and appears cost-effective. In pure financial terms, the cost seems justified for any air leak predicted to last greater than 8 days
- …