20 research outputs found
Recommended from our members
User’s Guide for Getter Rate Test System
This User’s Guide describes the operation and maintenance of the Getter Rate Test System, including the mechanical equipment, instrumentation, and datalogger/computer components. The Getter Rate Test System includes equipment and instrumentation to conduct two getter rate tests simultaneously. The mechanical equipment comprises roughing and high-vacuum pumps, heated test chambers, standard hydrogen leaks, and associated piping and valves. Instrumentation includes thermocouples, pressure (vacuum) transducers, panel displays, analog-to-digital signal converter, and associated wiring. The datalogger/computer is a stand-alone computer with installed software to allow the user to record data input from the pressure transducers to data files and to calculate the getter rate from the data in an Excel® spreadsheet
Testing Report: Littleford-Day Dryer Operation: Dryer Operation Impacts of Proposed MIS Mitigation Changes
Pacific Northwest National Laboratory performed a series of tests using the Littleford Day 22-liter dryer during investigations that evaluated changes in the melter-feed composition for the Demonstration Bulk Vitrification System. During testing, a new melter-feed formulation was developed that improved dryer performance while improving the retention of waste salts in the melter feed during vitrification
Colorectal Cancer Stage at Diagnosis Before vs During the COVID-19 Pandemic in Italy
IMPORTANCE Delays in screening programs and the reluctance of patients to seek medical
attention because of the outbreak of SARS-CoV-2 could be associated with the risk of more advanced
colorectal cancers at diagnosis.
OBJECTIVE To evaluate whether the SARS-CoV-2 pandemic was associated with more advanced
oncologic stage and change in clinical presentation for patients with colorectal cancer.
DESIGN, SETTING, AND PARTICIPANTS This retrospective, multicenter cohort study included all
17 938 adult patients who underwent surgery for colorectal cancer from March 1, 2020, to December
31, 2021 (pandemic period), and from January 1, 2018, to February 29, 2020 (prepandemic period),
in 81 participating centers in Italy, including tertiary centers and community hospitals. Follow-up was
30 days from surgery.
EXPOSURES Any type of surgical procedure for colorectal cancer, including explorative surgery,
palliative procedures, and atypical or segmental resections.
MAIN OUTCOMES AND MEASURES The primary outcome was advanced stage of colorectal cancer
at diagnosis. Secondary outcomes were distant metastasis, T4 stage, aggressive biology (defined as
cancer with at least 1 of the following characteristics: signet ring cells, mucinous tumor, budding,
lymphovascular invasion, perineural invasion, and lymphangitis), stenotic lesion, emergency surgery,
and palliative surgery. The independent association between the pandemic period and the outcomes
was assessed using multivariate random-effects logistic regression, with hospital as the cluster
variable.
RESULTS A total of 17 938 patients (10 007 men [55.8%]; mean [SD] age, 70.6 [12.2] years)
underwent surgery for colorectal cancer: 7796 (43.5%) during the pandemic period and 10 142
(56.5%) during the prepandemic period. Logistic regression indicated that the pandemic period was
significantly associated with an increased rate of advanced-stage colorectal cancer (odds ratio [OR],
1.07; 95%CI, 1.01-1.13; P = .03), aggressive biology (OR, 1.32; 95%CI, 1.15-1.53; P < .001), and stenotic
lesions (OR, 1.15; 95%CI, 1.01-1.31; P = .03).
CONCLUSIONS AND RELEVANCE This cohort study suggests a significant association between the
SARS-CoV-2 pandemic and the risk of a more advanced oncologic stage at diagnosis among patients
undergoing surgery for colorectal cancer and might indicate a potential reduction of survival for
these patients
Recommended from our members
Pulse Jet Mixing Tests With Noncohesive Solids
This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants. The test data were used to independently develop mixing models that can be used to predict full-scale WTP vessel performance and to rate current WTP mixing system designs against two specific performance requirements. One requirement is to ensure that all solids have been disturbed during the mixing action, which is important to release gas from the solids. The second requirement is to maintain a suspended solids concentration below 20 weight percent at the pump inlet. The models predict the height to which solids will be lifted by the PJM action, and the minimum velocity needed to ensure all solids have been lifted from the floor. From the cloud height estimate we can calculate the concentration of solids at the pump inlet. The velocity needed to lift the solids is slightly more demanding than "disturbing" the solids, and is used as a surrogate for this metric. We applied the models to assess WTP mixing vessel performance with respect to the two perform¬ance requirements. Each mixing vessel was evaluated against these two criteria for two defined waste conditions. One of the wastes was defined by design limits and one was derived from Hanford waste characterization reports. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The HLP-022 vessel was also evaluated using 12 m/s pulse jet velocity with 6-in. nozzles, and this design also did not satisfy the criteria for all of the conditions evaluated
Recommended from our members
Chemical and Radiochemical Analysis of Consolidated Sludge Samples from the K East Basin
This report describes results from analyses performed to characterize the consolidated sludge samples collected from the Hanford K East Basin in March and April 1999. The consolidated sludge samples were collected to provide additional material needed for the evaluation and design of systems that will be used to manage the K Basin sludge (i.e., disposition the sludge to T Plant for interim storage). The analytical results given in this report add to the knowledge on the composition of the K Basin sludge and provide specific information on this sludge necessary to plan and understand subsequent process testing. The following analyses were performed: weight percent (wt%) solids determination; uranium analysis by kinetic phosphorescence; plutonium isotope analysis by extraction chromatographic separation followed by alpha energy analysis (AEA); gross beta analysis; gamma energy analysis (GEA); and metals analysis by inductively coupled plasma atomic emission spectroscopy (ICP-AES)
Recommended from our members
Expert Panel Recommendations for Hanford Double-Shell Tank Life Extension
Expert workshops were held in Richland in May 2001 to review the Hanford Double-Shell Tank Integrity Project and make recommendations to extend the life of Hanford's double-shell waste tanks. The workshop scope was limited to corrosion of the primary tank liner, and the main areas for review were waste chemistry control, tank inspection, and corrosion monitoring. Participants were corrosion experts from Hanford, Savannah River Site, Brookhaven National Lab., Pacific Northwest National Lab., and several consultants. This report describes the current state of the three areas of the program, the final recommendations of the workshop, and the rationale for their selection