258 research outputs found

    Bionanotechnology and the Future of Glioma

    Get PDF
    Designer nanoscaled materials have the potential to revolutionize diagnosis and treatment for glioma. This review summarizes current progress in nanoparticle‑based therapies for glioma treatment including targeting, drug delivery, gene delivery, and direct tumor ablation. Preclinical and current human clinical trials are discussed. Although progress in the field has been significant over the past decade, many successful strategies demonstrated in the laboratory have yet to be implemented in human clinical trials. Looking forward, we provide examples of combined treatment strategies, which harness the potential for nanoparticles to interact with their biochemical environment, and simultaneously with externally applied photons or magnetic fields. We present our notion of the “ideal” nanoparticle for glioma, a concept that may soon be realized

    Improving levodopa delivery: IPX203, a novel extended-release carbidopa-levodopa formulation.

    Get PDF
    INTRODUCTION: IPX203 is a novel oral extended-release (ER) formulation of carbidopa (CD) and levodopa (LD) developed to address the short half-life and limited area for absorption of LD in the gastrointestinal tract. This paper presents the formulation strategy of IPX203 and its relationship to the pharmacokinetics (PK) and pharmacodynamic profile of IPX203 in Parkinson\u27s disease (PD) patients. METHODS: IPX203 was developed with an innovative technology containing immediate-release (IR) granules and ER beads that provides rapid LD absorption to achieve desired plasma concentration and maintaining it within the therapeutic range for longer than can be achieved with current oral LD formulations. The PK and pharmacodynamics of IPX203 were compared with IR CD-LD in a Phase 2, open-label, rater-blinded, multicenter, crossover study in patients with advanced PD. RESULTS: Pharmacokinetic data showed that on Day 15, LD concentrations were sustained above 50% of peak for 6.2 h with IPX203 vs. 3.9 h with IR CD-LD (P = 0.0002). Pharmacodynamic analysis demonstrated that mean MDS-UPDRS Part III scores prior to administration of the first daily dose were significantly lower among patients receiving IPX203 than IR CD-LD (LS mean difference –8.1 [25.0], P = 0.0255). In a study conducted in healthy volunteers, a high-fat, high-calorie meal delayed plasma LD Tmax by 2 h, and increased Cmax and AUCtau by approximately 20% compared with a fasted state. Sprinkling capsule contents on applesauce did not affect PK parameters. CONCLUSION: These data confirm that the unique design of IPX203 addresses some of the limitations of oral LD delivery

    Nanoparticle mediated silencing of DNA repair sensitizes pediatric brain tumor cells to y-irradiation

    Get PDF
    Medulloblastoma (MB) and ependymoma (EP) are the most common pediatric brain tumors, afflicting 3000 children annually. Radiotherapy (RT) is an integral component in the treatment of these tumors; however, the improvement in survival is often accompanied by radiation-induced adverse developmental and psychosocial sequelae. Therefore, there is an urgent need to develop strategies that can increase the sensitivity of brain tumors cells to RT while sparing adjacent healthy brain tissue. Apurinic endonuclease 1 (Ape1), an enzyme in the base excision repair pathway, has been implicated in radiation resistance in cancer. Pharmacological and specificity limitations inherent to small molecule inhibitors of Ape1 have hindered their clinical development. Here we report on a nanoparticle (NP) based siRNA delivery vehicle for knocking down Ape1 expression and sensitizing pediatric brain tumor cells to RT. The NP comprises a superparamagnetic iron oxide core coated with a biocompatible, biodegradable coating of chitosan, polyethylene glycol (PEG), and polyethyleneimine (PEI) that is able to bind and protect siRNA from degradation and to deliver siRNA to the perinuclear region of target cells. NPs loaded with siRNA against Ape1 (NP:siApe1) knocked down Ape1 expression over 75% in MB and EP cells, and reduced Ape1 activity by 80%. This reduction in Ape1 activity correlated with increased DNA damage post-irradiation, which resulted in decreased cell survival in clonogenic assays. The sensitization was specific to therapies generating abasic lesions as evidenced by NP:siRNA not increasing sensitivity to paclitaxel, a microtubule disrupting agent. Our results indicate NP-mediated delivery of siApe1 is a promising strategy for circumventing pediatric brain tumor resistance to RT

    Microvolt T-wave alternans testing provides a reliable means of guiding anti-arrhythmic therapy

    Get PDF
    Gupta et al1 present a meta-analysis and conclude that microvolt T-wave alternans testing (MTWA) does not modify risk of sudden cardiac death (SCD) sufficiently for clinical use. Their analysis involves a number of methodological limitations. The authors included in their primary analysis numerous surrogates for sudden cardiac death (SCD) such as ICD therapy, cardiac mortality and total mortality

    Rapid Pharmacokinetic and Biodistribution Studies Using Cholorotoxin-Conjugated Iron Oxide Nanoparticles: A Novel Non-Radioactive Method

    Get PDF
    Recent advances in nanotechnology have led to the development of biocompatible nanoparticles for in vivo molecular imaging and targeted therapy. Many nanoparticles have undesirable tissue distribution or unacceptably low serum half-lives. Pharmacokinetic (PK) and biodistribution studies can help inform decisions determining particle size, coatings, or other features early in nanoparticle development. Unfortunately, these studies are rarely done in a timely fashion because many nanotechnology labs lack the resources and expertise to synthesize radioactive nanoparticles and evaluate them in mice.To address this problem, we developed an economical, radioactivity-free method for assessing serum half-life and tissue distribution of nanoparticles in mice. Iron oxide nanoparticles coated with chitosan and polyethylene glycol that utilize chlorotoxin as a targeting molecule have a serum half-life of 7-8 hours and the particles remain stable for extended periods of time in physiologic fluids and in vivo. Nanoparticles preferentially distribute to spleen and liver, presumably due to reticuloendothelial uptake. Other organs have very low levels of nanoparticles, which is ideal for imaging most cancers in the future. No acute toxicity was attributed to the nanoparticles.We report here a simple near-infrared fluorescence based methodology to assess PK properties of nanoparticles in order to integrate pharmacokinetic data into early nanoparticle design and synthesis. The nanoparticles tested demonstrate properties that are excellent for future clinical imaging strategies and potentially suitable for targeted therapy

    OXYGEN REACTIVE POLYMERS FOR TREATMENT OF TRAUMATIC BRAIN INJURY

    Get PDF
    Methods and compositions for treating traumatic brain injury . The methods and compositions utilize a multi - functional oxygen reactive polymer ( ORP ) that includes repeating units that include a reactive oxygen species ( ROS ) scavenging group and a polyalkylene oxide group . For theranostic applications , the oxygen reactive polymer fur ther includes a diagnostic group

    Changes in Parkinson's disease sleep symptoms and daytime somnolence after bilateral subthalamic deep brain stimulation in Parkinson's disease

    Get PDF
    AbstractIntroduction: Deep brain stimulation (DBS) markedly improves motor function in advanced Parkinson’s disease (PD), but its effect on sleep is less clear. Patients and methods: Forty PD patients who had subthalamic DBS (STN-DBS) were identified from an on-going non-motor naturalistic longitudinal study (NILS). All patients were followed up for at least 6 months, 26 patients had a 1 year follow-up. A total PDSS score of 100 or less, a score in any PDSS-item of 6 or less, and a Epworth score of 10 or more were classified as being significant. Results: Forty-five percent of patients reported significant improvement in the total PDSS score at 6 months, and 35% at 12 months. In terms of magnitude, the total PDSS score at 6 months was significantly improved from baseline while the improvement at 12 months was not statistically significant. The most frequently reported improvements were overall sleep quality and maintenance of sleep. Some patients reported worsening of the total PDSS score. More than half of the patients reporting daytime sleepiness at baseline had persistent sleepiness at 6 and 12 months. The mean Epworth Score did not improve because a significant number of patients without sleepiness at baseline reported new-onset sleepiness at 6 and 12 months. Neither medication changes nor motor improvement were consistently related to sleep changes after DBS. Conclusion: Subthalamic DBS is associated with a statistically and clinically significant, but variable, improvement in sleep as measured by the PDSS. The most frequent improvements were better overall sleep quality and better sleep maintenance.</jats:p

    Evidence regarding clinical use of microvolt T-wave alternans

    Get PDF
    Background: Microvolt T-wave alternans (MTWA) testing in many studies has proven to be a highly accurate predictor of ventricular tachyarrhythmic events (VTEs) in patients with risk factors for sudden cardiac death (SCD) but without a prior history of sustained VTEs (primary prevention patients). In some recent studies involving primary prevention patients with prophylactically implanted cardioverter-defibrillators (ICDs), MTWA has not performed as well. Objective: This study examined the hypothesis that MTWA is an accurate predictor of VTEs in primary prevention patients without implanted ICDs, but not of appropriate ICD therapy in such patients with implanted ICDs. Methods: This study identified prospective clinical trials evaluating MTWA measured using the spectral analytic method in primary prevention populations and analyzed studies in which: (1) few patients had implanted ICDs and as a result none or a small fraction (≤15%) of the reported end point VTEs were appropriate ICD therapies (low ICD group), or (2) many of the patients had implanted ICDs and the majority of the reported end point VTEs were appropriate ICD therapies (high ICD group). Results: In the low ICD group comprising 3,682 patients, the hazard ratio associated with a nonnegative versus negative MTWA test was 13.6 (95% confidence interval [CI] 8.5 to 30.4) and the annual event rate among the MTWA-negative patients was 0.3% (95% CI: 0.1% to 0.5%). In contrast, in the high ICD group comprising 2,234 patients, the hazard ratio was only 1.6 (95% CI: 1.2 to 2.1) and the annual event rate among the MTWA-negative patients was elevated to 5.4% (95% CI: 4.1% to 6.7%). In support of these findings, we analyzed published data from the Multicenter Automatic Defibrillator Trial II (MADIT II) and Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) trials and determined that in those trials only 32% of patients who received appropriate ICD therapy averted an SCD. Conclusion: This study found that MTWA testing using the spectral analytic method provides an accurate means of predicting VTEs in primary prevention patients without implanted ICDs; in particular, the event rate is very low among such patients with a negative MTWA test. In prospective trials of ICD therapy, the number of patients receiving appropriate ICD therapy greatly exceeds the number of patients who avert SCD as a result of ICD therapy. In trials involving patients with implanted ICDs, these excess appropriate ICD therapies seem to distribute randomly between MTWA-negative and MTWA-nonnegative patients, obscuring the predictive accuracy of MTWA for SCD. Appropriate ICD therapy is an unreliable surrogate end point for SCD

    What are the critical elements of sideline screening that can be used to establish the diagnosis of concussion? A systematic review

    Get PDF
    BACKGROUND : Sideline detection is the first and most significant step in recognising a potential concussion and removing an athlete from harm. This systematic review aims to evaluate the critical elements aiding sideline recognition of potential concussions including screening tools, technologies and integrated assessment protocols. DATA SOURCES : Bibliographic databases, grey literature repositories and relevant websites were searched from 1 January 2000 to 30 September 2016. A total of 3562 articles were identified. STUDY SELECTION : Original research studies evaluating a sideline tool, technology or protocol for sports-related concussion were eligible, of which 27 studies were included. DATA EXTRACTION : A standardised form was used to record information. The QUADAS-2 and Newcastle-Ottawa tools were used to rate risk of bias. Strength of evidence was assessed using the Grades of Recommendation, Assessment, Development and Evaluation Working Group system. DATA SYNTHESIS : Studies assessing symptoms, the King-Devick test and multimodal assessments reported high sensitivity and specificity. Evaluations of balance and cognitive tests described lower sensitivity but higher specificity. However, these studies were at high risk of bias and the overall strength of evidence examining sideline screening tools was very low. A strong body of evidence demonstrated that head impact sensors did not provide useful sideline concussion information. Low-strength evidence suggested a multimodal, multitime-based concussion evaluation process incorporating video review was important in the recognition of significant head impact events and delayed onset concussion. CONCLUSION : Conclusion In the absence of definitive evidence confirming the diagnostic accuracy of sideline screening tests, consensus-derived multimodal assessment tools, such as the Sports Concussion Assessment Tool, are recommended. Sideline video review may improve recognition and removal from play of athletes who have sustained significant head impact events. Current evidence does not support the use of impact sensor systems for real-time concussion identification.The National Institute for Health Research and World Rugby.http://bjsm.bmj.comhj2017Sports Medicin
    • …
    corecore