616 research outputs found

    A placebo-controlled, double-blind, randomized, multicenter study to assess the effects of dronedarone 400 mg twice daily for 12 weeks on atrial fibrillation burden in subjects with permanent pacemakers

    Get PDF
    Purpose Dronedarone is a benzofuran derivative with a pharmacological profile similar to amiodarone but has a more rapid onset of action and a much shorter half-life (13–19 h). Our goal was to evaluate the efficacy of dronedarone in atrial fibrillation (AF) patients using dual-chamber pacemakers capable of quantifying atrial fibrillation burden. Methods Pacemakers were adjusted to optimize AF detection. Patients with AF burden \u3e1 % were randomized to dronedarone 400 mg twice daily (BID) or placebo. Pacemakers were interrogated after 4 and 12 weeks of treatment. The primary endpoint was the change in AF burden from baseline over the 12-week treatment period. Patients with permanent AF, severe/recently decompensated heart failure, and current use of antiarrhythmic drugs were excluded. AF burden was assessed by a core laboratory blinded to treatment assignment. Results From 285 patients screened, 112 were randomized (mean age 76 years, 60 % male, 84 % hypertensive, 65 % with sick sinus syndrome, 26 % with diabetes mellitus type II, 15 % with heart failure). Baseline mean (SEM) AF burden was 8.77 % (0.16) for placebo and 10.14 % (0.17) for dronedarone. Over the 12-week study period, AF burden compared to baseline decreased by 54.4 % (0.22) (P = 0.0009) with dronedarone and trended higher by 12.8 % (0.16) (P = 0.450) with placebo. The absolute change in burden was decreased by 5.5 % in the dronedarone group and increased by 1.1 % in the placebo group. Heart rate during AF was reduced to approximately 4 beats/min with dronedarone (P = 0.285). Adverse events were higher with dronedarone compared to placebo (65 vs 56 %). Conclusions Dronedarone reduced pacemaker-assessed the relative AF burden compared to baseline and placebo by over 50 % during the 12-week observation period

    Improving levodopa delivery: IPX203, a novel extended-release carbidopa-levodopa formulation.

    Get PDF
    INTRODUCTION: IPX203 is a novel oral extended-release (ER) formulation of carbidopa (CD) and levodopa (LD) developed to address the short half-life and limited area for absorption of LD in the gastrointestinal tract. This paper presents the formulation strategy of IPX203 and its relationship to the pharmacokinetics (PK) and pharmacodynamic profile of IPX203 in Parkinson\u27s disease (PD) patients. METHODS: IPX203 was developed with an innovative technology containing immediate-release (IR) granules and ER beads that provides rapid LD absorption to achieve desired plasma concentration and maintaining it within the therapeutic range for longer than can be achieved with current oral LD formulations. The PK and pharmacodynamics of IPX203 were compared with IR CD-LD in a Phase 2, open-label, rater-blinded, multicenter, crossover study in patients with advanced PD. RESULTS: Pharmacokinetic data showed that on Day 15, LD concentrations were sustained above 50% of peak for 6.2 h with IPX203 vs. 3.9 h with IR CD-LD (P = 0.0002). Pharmacodynamic analysis demonstrated that mean MDS-UPDRS Part III scores prior to administration of the first daily dose were significantly lower among patients receiving IPX203 than IR CD-LD (LS mean difference –8.1 [25.0], P = 0.0255). In a study conducted in healthy volunteers, a high-fat, high-calorie meal delayed plasma LD Tmax by 2 h, and increased Cmax and AUCtau by approximately 20% compared with a fasted state. Sprinkling capsule contents on applesauce did not affect PK parameters. CONCLUSION: These data confirm that the unique design of IPX203 addresses some of the limitations of oral LD delivery

    The Sleeping Brain's Influence on Verbal Memory: Boosting Resistance to Interference

    Get PDF
    Memories evolve. After learning something new, the brain initiates a complex set of post-learning processing that facilitates recall (i.e., consolidation). Evidence points to sleep as one of the determinants of that change. But whenever a behavioral study of episodic memory shows a benefit of sleep, critics assert that sleep only leads to a temporary shelter from the damaging effects of interference that would otherwise accrue during wakefulness. To evaluate the potentially active role of sleep for verbal memory, we compared memory recall after sleep, with and without interference before testing. We demonstrated that recall performance for verbal memory was greater after sleep than after wakefulness. And when using interference testing, that difference was even more pronounced. By introducing interference after sleep, this study confirms an experimental paradigm that demonstrates the active role of sleep in consolidating memory, and unmasks the large magnitude of that benefit

    What is Microbial Dormancy?

    Get PDF
    Life can be stressful. One way to deal with stress is to simply wait it out. Microbes do this by entering a state of reduced activity and increased resistance commonly called ‘dormancy’. But what is dormancy? Different scientific disciplines emphasize distinct traits and phenotypic ranges in defining dormancy for their microbial species and system-specific questions of interest. Here, we propose a unified definition of microbial dormancy, using a broad framework to place earlier discipline-specific definitions in a new context. We then discuss how this new definition and framework may improve our ability to investigate dormancy using multi-omics tools. Finally, we leverage our framework to discuss the diversity of genomic mechanisms for dormancy in an extreme environment that challenges easy definitions – the permafrost

    OXYGEN REACTIVE POLYMERS FOR TREATMENT OF TRAUMATIC BRAIN INJURY

    Get PDF
    Methods and compositions for treating traumatic brain injury . The methods and compositions utilize a multi - functional oxygen reactive polymer ( ORP ) that includes repeating units that include a reactive oxygen species ( ROS ) scavenging group and a polyalkylene oxide group . For theranostic applications , the oxygen reactive polymer fur ther includes a diagnostic group

    Rate-equation calculations of the current flow through two-site molecular device and DNA-based junction

    Full text link
    Here we present the calculations of incoherent current flowing through the two-site molecular device as well as the DNA-based junction within the rate-equation approach. Few interesting phenomena are discussed in detail. Structural asymmetry of two-site molecule results in rectification effect, which can be neutralized by asymmetric voltage drop at the molecule-metal contacts due to coupling asymmetry. The results received for poly(dG)-poly(dC) DNA molecule reveal the coupling- and temperature-independent saturation effect of the current at high voltages, where for short chains we establish the inverse square distance dependence. Besides, we document the shift of the conductance peak in the direction to higher voltages due to the temperature decrease.Comment: 12 pages, 6 figure

    Initial Independent Outcomes from Focal Impulse and Rotor Modulation Ablation for Atrial Fibrillation: Multicenter FIRM Registry

    Get PDF
    Introduction The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. Methods We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View™; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. Results Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145–354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). Conclusions Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center’s first cases
    • …
    corecore