330 research outputs found

    Development of an analogue optical link for the front-end read-out of the ATLAS electromagnetic calorimeter

    Get PDF
    We have developed an analogue optical data transmission system intended to meet the read-out requirements of the ATLAS liquid argon electromagnetic calorimeter. Eight-way demonstrators have been built and tested. The link uses arrays of VCSEL diodes as the optical emitters, coupled to a 70 m long fibre ribbon to simulate the distance between the detector and the control room. The receiver is based around a custom-designed PIN photodiode array. We describe here the final results of laboratory tests on a demonstrator, laying stress on the VCSEL-to-fibre coupling issues, and the overall performance of the full link. A 9-bit dynamic range is achieved, with a 5on-linearity

    Construction and test of a fine-grained liquid argon preshower prototype

    Get PDF
    A separate liquid argon preshower detector consisting of two layers featuring a fine granularity of 2.5~103^{\mathrm{-3}} was studied by the RD3 collaboration. A prototype covering approximately 0.8 in pseudo-rapidity and 9 degrees in azimuth was built and tested at CERN in July 94. CMOS and GaAs VLSI preamplifiers were designed and tested for this occasion. The combined response of this detector and an accordion electromagnetic calorimeter prototype to muons, electrons and photons is presented. For minimum ionizing tracks a signal-to-noise ratio of 4.5 per preshower layer was measured. Above 150~GeV the space resolution for electrons is better than 250~μ\mum in both directions. The precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 4 mrad above 50~GeV. It is concluded that the preshower detector would adequately fulfil its role for future operation at CERN Large Hadron Collider

    Are time-trends of smoking among pregnant immigrant women in Sweden determined by cultural or socioeconomic factors?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The widening socioeconomic gap in smoking during pregnancy remains a challenge to the Swedish antenatal care services. However, the influence of cultural factors in explaining the socioeconomic differences in smoking during pregnancy is not clear among the immigrant women. The aim of this study was to investigate whether the development of smoking prevalence among pregnant immigrant women in Sweden followed the trajectory which could be expected from the stages of the global smoking epidemic model in the women's countries of origin, or not.</p> <p>Methods</p> <p>Delivery data on pregnancies in Sweden from 1982 to 2001 was collected from the Swedish Medical Birth Registry. From a total of 2,224,469 pregnant women during this period, all immigrant pregnant women (n = 234,731) were selected to this study. A logistic regression analysis and attributable fraction were used to investigate the association between smoking during pregnancy and the socioeconomic differences among immigrant women.</p> <p>Results</p> <p>Overall, the prevalence of smoking among pregnant immigrant women decreased from 30.3% in 1982 to 11.0% in 2001, albeit with remarkable differences between educational levels and country of origin. The greatest decline of absolute prevalence was recorded among low educated women (27,9%) and among other Nordic countries (17,9%). In relative terms, smoking inequalities increased between educational levels regardless of country of origin. The odds ratios for low educational level for women from other Nordic countries increased from 4.9 (95% CI 4.4-5.4) in 1982 to 13.4 (95% CI 11.2-16.2) in 2001, as compared to women with high education in the same group. Further, the total attributable fraction for educational difference increased from 55% in 1982 to 62% in 2001, demonstrating the strong effect of educational attainment.</p> <p>Conclusions</p> <p>Our hypothesis that the socioeconomic time trend of smoking based on the stage of the world wide tobacco epidemic model related to country of origin of the immigrant women was not supported by our analyses. Our findings does not support a call for specific "culture sensitive" antismoking policies or interventions in Sweden or similar countries, but reinforce the existing evidence with a focus on women with a low educational level, regardless of cultural background.</p

    The type II RAF inhibitor tovorafenib in relapsed/refractory pediatric low-grade glioma: the phase 2 FIREFLY-1 trial

    Get PDF
    \ua9 2023, The Author(s).BRAF genomic alterations are the most common oncogenic drivers in pediatric low-grade glioma (pLGG). Arm 1 (n = 77) of the ongoing phase 2 FIREFLY-1 (PNOC026) trial investigated the efficacy of the oral, selective, central nervous system–penetrant, type II RAF inhibitor tovorafenib (420 mg m−2 once weekly; 600 mg maximum) in patients with BRAF-altered, relapsed/refractory pLGG. Arm 2 (n = 60) is an extension cohort, which provided treatment access for patients with RAF-altered pLGG after arm 1 closure. Based on independent review, according to Response Assessment in Neuro-Oncology High-Grade Glioma (RANO-HGG) criteria, the overall response rate (ORR) of 67% met the arm 1 prespecified primary endpoint; median duration of response (DOR) was 16.6 months; and median time to response (TTR) was 3.0 months (secondary endpoints). Other select arm 1 secondary endpoints included ORR, DOR and TTR as assessed by Response Assessment in Pediatric Neuro-Oncology Low-Grade Glioma (RAPNO) criteria and safety (assessed in all treated patients and the primary endpoint for arm 2, n = 137). The ORR according to RAPNO criteria (including minor responses) was 51%; median DOR was 13.8 months; and median TTR was 5.3 months. The most common treatment-related adverse events (TRAEs) were hair color changes (76%), elevated creatine phosphokinase (56%) and anemia (49%). Grade ≥3 TRAEs occurred in 42% of patients. Nine (7%) patients had TRAEs leading to discontinuation of tovorafenib. These data indicate that tovorafenib could be an effective therapy for BRAF-altered, relapsed/refractory pLGG. ClinicalTrials.gov registration: NCT04775485

    Durable response with single-agent acalabrutinib in patients with relapsed or refractory mantle cell lymphoma

    Get PDF
    Bruton tyrosine kinase (BTK) inhibitors have greatly improved the spectrum of treatment options in mantle cell lymphoma (MCL) [1–4]. Acalabrutinib is a highly selective, orally administered, and potent BTK inhibitor with limited off-target activity [5]. Acalabrutinib was approved in 2017 by the US Food and Drug Administration for the treatment of relapsed/refractory MCL based on clinical data from the open-label, multicenter, phase 2 ACE-LY-004 study of acalabrutinib 100 mg twice daily [1]. Here, we present updated results from the ACE-LY-004 study after a median 26-month follow-up. Eligibility criteria and study design were published previously (Supplementary methods) [1]. Analysis of minimal residual disease (MRD) was conducted after complete response (CR) or partial response (PR) was achieved using the quantitative ClonoSEQ next-generation sequencing (5 × 10−6 ) assay (Adpative Biotechnologies, Seattle, WA, USA) in consenting patients with available paired archival tumor and whole blood samples. Data are updated as of February 12, 2018

    Performance of an endcap prototype of the ATLAS accordion electromagnetic calorimeter

    Get PDF
    The design and construction of a lead-liquid argon endcap calorimeter prototype using an accordion geometry and conceived as a sector of the inner wheel of the endcap calorimeter of the future ATLAS experiment at the LHC is described. The performance obtained using electron beam data is presented. The main results are an energy resolution with a sampling term below 11%/E(GeV)11\%/\sqrt{E(\rm GeV)} and a small local constant term, a good linearity of the response with the incident energy and a global constant term of 0.8\% over an extended area in the rapidity range of 2.2<η<2.92.2 < \eta <2.9. These properties make the design suitable for the ATLAS electromagnetic endcap calorimeter

    Construction and test of a fine-grained liquid argon preshower prototype

    Get PDF
    A separate liquid argon preshower detector consisting of two layers featuring a fine granularity of 2.5~103^{\mathrm{-3}} was studied by the RD3 collaboration. A prototype covering approximately 0.8 in pseudo-rapidity and 9 degrees in azimuth was built and tested at CERN in July 94. CMOS and GaAs VLSI preamplifiers were designed and tested for this occasion. The combined response of this detector and an accordion electromagnetic calorimeter prototype to muons, electrons and photons is presented. For minimum ionizing tracks a signal-to-noise ratio of 4.5 per preshower layer was measured. Above 150~GeV the space resolution for electrons is better than 250~μ\mum in both directions. The precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 4 mrad above 50~GeV. It is concluded that the preshower detector would adequately fulfil its role for future operation at CERN Large Hadron Collider

    Performance of a large scale prototype of the ATLAS accordion electromagnetic calorimeter

    Get PDF
    A 2 m long prototype of a lead-liquid argon electromagnetic calorimeter with accordion-shaped electrodes, conceived as a sector of the barrel calorimeter of the future ATLAS experiment at the LHC, has been tested with electron and pion beams in the energy range 10 to 287 GeV. A sampling term of 10%/root E(GeV) was obtained for electrons in the rapidity range 0 < eta < 1, while the constant term measured over an area of about 1 m(2) is 0.69%. With a cell size of 2.7 cm the position resolution is. about 4 mm/root E(GeV)

    Performance of an endcap prototype of the Atlas accordion electromagnetic calorimeter

    Get PDF
    The design and construction of a lead-liquid argon endcap calorimeter prototype using an accordion geometry and conceived as a sector of the inner wheel of the endcap calorimeter of the future ATLAS experiment at the LHC is described. The performance obtained using electron beam data is presented. The main results are an energy resolution with a sampling term below 11%/E(GeV)11\%/\sqrt{E(\rm GeV)} and a small local constant term, a good linearity of the response with the incident energy and a global constant term of 0.8\% over an extended area in the rapidity range of 2.2η2.92.2\eta 2.9. These properties make the design suitable for the ATLAS electromagnetic endcap calorimeter
    corecore