31 research outputs found

    Shotgun Proteomics Identifies Serum Fibronectin as a Candidate Diagnostic Biomarker for Inclusion in Future Multiplex Tests for Ectopic Pregnancy

    Get PDF
    Ectopic pregnancy (EP) is difficult to diagnose early and accurately. Women often present at emergency departments in early pregnancy with a 'pregnancy of unknown location' (PUL), and diagnosis and exclusion of EP is challenging due to a lack of reliable biomarkers. The objective of this study was to identify novel diagnostic biomarkers for EP. Shotgun proteomics, incorporating combinatorial-ligand library pre-fractionation, was used to interrogate pooled sera (n = 40) from women undergoing surgery for EP, termination of viable intrauterine pregnancy and management of non-viable intrauterine pregnancy. Western blot was used to validate results in individual sera. ELISAs were developed to interrogate sera from women with PUL (n = 120). Sera were collected at time of first symptomatic presentation and categorized according to pregnancy outcome. The main outcome measures were differences between groups and area under the receiver operating curve (ROC). Proteomics identified six biomarker candidates. Western blot detected significant differences in levels of two of these candidates. ELISA of sera from second cohort revealed that these differences were only significant for one of these candidates, fibronectin. ROC analysis of ability of fibronectin to discriminate EP from other pregnancy outcomes suggested that fibronectin has diagnostic potential (ROC 0.6439; 95% CI 0.5090 to 0.7788; P>0.05), becoming significant when 'ambiguous' medically managed PUL excluded from analysis (ROC 0.6538; 95% CI 0.5158 to 0.7918; P<0.05). Fibronectin may make a useful adjunct to future multiplex EP diagnostic tests

    A Systematic Analysis of Eluted Fraction of Plasma Post Immunoaffinity Depletion: Implications in Biomarker Discovery

    Get PDF
    Plasma is the most easily accessible source for biomarker discovery in clinical proteomics. However, identifying potential biomarkers from plasma is a challenge given the large dynamic range of proteins. The potential biomarkers in plasma are generally present at very low abundance levels and hence identification of these low abundance proteins necessitates the depletion of highly abundant proteins. Sample pre-fractionation using immuno-depletion of high abundance proteins using multi-affinity removal system (MARS) has been a popular method to deplete multiple high abundance proteins. However, depletion of these abundant proteins can result in concomitant removal of low abundant proteins. Although there are some reports suggesting the removal of non-targeted proteins, the predominant view is that number of such proteins is small. In this study, we identified proteins that are removed along with the targeted high abundant proteins. Three plasma samples were depleted using each of the three MARS (Hu-6, Hu-14 and Proteoprep 20) cartridges. The affinity bound fractions were subjected to gelC-MS using an LTQ-Orbitrap instrument. Using four database search algorithms including MassWiz (developed in house), we selected the peptides identified at <1% FDR. Peptides identified by at least two algorithms were selected for protein identification. After this rigorous bioinformatics analysis, we identified 101 proteins with high confidence. Thus, we believe that for biomarker discovery and proper quantitation of proteins, it might be better to study both bound and depleted fractions from any MARS depleted plasma sample

    High Abundance Proteins Depletion vs Low Abundance Proteins Enrichment: Comparison of Methods to Reduce the Plasma Proteome Complexity

    Get PDF
    BACKGROUND: To date, the complexity of the plasma proteome exceeds the analytical capacity of conventional approaches to isolate lower abundance proteins that may prove to be informative biomarkers. Only complex multistep separation strategies have been able to detect a substantial number of low abundance proteins (<100 ng/ml). The first step of these protocols is generally the depletion of high abundance proteins by the use of immunoaffinity columns or, alternatively, the enrichment of by the use of solid phase hexapeptides ligand libraries. METHODOLOGY/PRINCIPAL FINDINGS: Here we present a direct comparison of these two approaches. Following either approach, the plasma sample was further fractionated by SCX chromatography and analyzed by RP-LC-MS/MS with a Q-TOF mass spectrometer. The depletion of the 20 most abundant plasma proteins allowed the identification of about 25% more proteins than those detectable following low abundance proteins enrichment. The two datasets are partially overlapping and the identified proteins belong to the same order of magnitude in terms of plasma concentration. CONCLUSIONS/SIGNIFICANCE: Our results show that the two approaches give complementary results. However, the enrichment of low abundance proteins has the great advantage of obtaining much larger amount of material that can be used for further fractionations and analyses and emerges also as a cheaper and technically simpler approach. Collectively, these data indicate that the enrichment approach seems more suitable as the first stage of a complex multi-step fractionation protocol
    corecore