34 research outputs found

    An In Vitro Comparison of Different Diagnostic Methods in Detection of Residual Dentinal Caries

    Get PDF
    The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 μm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection

    Effectiveness of Functional Electrical Stimulation - Cycling Treatment in Children with Cerebral Palsy

    Get PDF
    AimThe purpose of this study was to evaluate the effects of functional electrical stimulation (FES) bicycle therapy system on motor function, gait pattern, spasticity, daily living activities, and aerobic capacity in children with cerebral palsy (CP) and to compare the results with sham stimulation and standard treatment.MethodsPatients with cerebral palsy who received botulinum toxin type-A injections to lower extremities and those with Gross Motor Function Measure Classification System (GMFCS) levels I – III, were included in the study. Twenty-five patients were randomly assigned into three treatment groups for 4-weeks: Group 1, FES-cycling and standard treatment; Group 2, Sham stimulus FES-cycling and standard treatment; Group 3, Standard treatment. Clinical assessment tools included the Modified Ashworth Scale (MAS), Modified Tardieu Scale (MTS), Pediatric Functional Independence Measure (WeeFIM), GMFCS, Gross Motor Function Measure-88 (GMFM-88), selective motor control tests, 6-minute walk test, and Visual Gait Analysis (VGA).ResultsIn all groups, there were significant improvements in MAS, MTS, WeeFIM, GMFM-88, 6-minute walk test, and VGA scores. No changes in GMFCS levels were observed in any group. At the end of the study, there was no significant difference among the groups in terms of any clinical assessment parameter.ConclusionsAll groups showed statistically significant improvements in motor function, walking pattern, spasticity, daily living activities, and aerobic capacity in patients with CP following the rehabilitation period. Although FES-cycling demonstrated no superiority over the other approaches and provided no additional benefit to the results, FES appears to be safe and well-tolerated in children with CP, at least as much as standard exercise treatment

    Magnetic resonance imaging study of corpus callosum abnormalities in patients with different subtypes of schizophrenia

    Get PDF
    Background. Reductions in the size of the corpus callosum (CC) have been described for schizophrenia patients, but little is known about the possible regional differences in schizophrenia subtypes (paranoid, disorganised, undifferentiated, residual).  Methods. We recruited 58 chronically schizophrenic patients with different subtypes, and 31 age-and-gender matched healthy controls. The callosum was extracted from a midsagittal slice from T1 weighted magnetic resonance images, and areas of the total CC, its five subregions, CC length and total brain volume were compared between schizophrenia subtypes and controls. Five subregions were approximately matched to fibre pathways from cortical regions.  Results. Schizophrenia patients had reduced CC total area and length when compared with controls. Disorganised and undifferentiated schizophrenics had a smaller prefrontal area, while there was no significant difference for the paranoid and residual groups. The premotor/supplementary motor area was smaller in all schizophrenia subtypes. The motor area was smaller only in the disorganised group. A smaller sensory area was found in all subtypes except the residual group. Parietal, temporal and occipital areas were smaller in the paranoid and undifferentiated groups. Total brain volume was smaller in all schizophrenia subtypes compared with controls, but did not reach statistical significance.  Conclusion. These findings suggest that the heterogeneity of symptoms may lead to the different CC morphological characteristics in schizophrenia subtypes

    Diagnostic value of diffusion weighted MRI and ADC in differential diagnosis of cavernous hemangioma of the liver.

    Get PDF
    Aims: To investigate the use of diffusion weighted magnetic resonance imaging (DWI) and the apparent diffusion coefficient (ADC) values in the diagnosis of hemangioma. Materials and methods: The study population consisted of 72 patients with liver masses larger than 1 cm (72 focal lesions). DWI examination with a b value of 600 s/mm2 was carried out for all patients. After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the \u201ccut-off\u201d ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing hemangioma, benign and malignant lesions were researched. Results: Of the 72 liver masses, 51 were benign and 21 were malignant. Benign lesions comprised 38 hemangiomas and 13 simple cysts. Malignant lesions comprised 9 hepatocellular carcinomas, and 12 metastases. The highest ADC values were measured for cysts (3.782\ub10.53 710-3 mm2/s) and hemangiomas (2.705\ub10.63 710-3 mm2/s). The average ADC value of hemangiomas was significantly higher than malignant lesions and the normal control group (p<0.001). The average ADC value of cysts were significantly higher when compared to hemangiomas and normal control group (p<0.001). To distinguish hemangiomas from malignant liver lesions, the \u201ccut-off\u201d ADC value of 1.800 710-3 mm2/s had a sensitivity of 97.4% and a specificity of 90.9%. To distinguish hemangioma from normal liver parenchyma the \u201ccut-off\u201d value of 1.858 710-3 mm2/s had a sensitivity of 97.4% and a specificity of 95.7%. To distinguish benign liver lesions from malignant liver lesions the \u201ccut-off\u201d value of 1.800 710-3 mm2/s had a sensitivity of 96.1% and a specificity of 90.0%. Conclusion: DWI and quantitative measurement of ADC values can be used in differential diagnosis of benign and malignant liver lesions and also in the diagnosis and differentiation of hemangiomas. When dynamic examination cannot distinguish cases with vascular metastasis and lesions from hemangioma, DWI and ADC values can be useful in the primary diagnosis and differential diagnosis. The technique does not require contrast material, so it can safely be used in patients with renal failure. Keywords

    The fate of abstracts presented at Turkish national radiology congresses in 2010-2012

    Get PDF
    PURPOSEThis study aims to evaluate the analysis and publication rates of abstracts presented at the Turkish National Radiology meetings in 2010–2012.METHODSAbstracts presented in the national radiology meetings of 2010, 2011, and 2012 were included in the study. The presentations were classified according to presentation type (oral or poster presentations), study type, study design, imaged organ or body systems, imaging modalities, time interval between the presentation and the publication date, and the journal in which the article was published. The conversion rate of presentations into full-text articles in peer-reviewed journals were surveyed through PubMed. The time from presentation in the meetings to publication was determined. The distribution of journals was also demonstrated.RESULTSThe total number of presentations submitted in three national radiology meetings was 3,192. The publication rate was 11% for the 2010 meeting, 8.2% for the 2011 meeting, and 9.6% for the 2012 meeting. A total of 300 papers were published, with an average of 15 months (range, 0–42 months) between presentation and final publication. The first three refereed international journals with the most number of papers derived from these meetings were Diagnostic and Interventional Radiology, Clinical Imaging, and European Journal of Radiology.CONCLUSIONThe overall publication rate of scientific abstracts from Turkey was lower than those from overseas countries. Encouraging the authors to conduct higher-quality research would raise the publication rate as well as improve the quality and success of our scientific meetings

    Splinting in carpal tunnel syndrome—should we use it during the daytime?

    No full text
    Abstract Background Splinting is frequently used in the treatment of CTS (carpal tunnel syndrome) and is mostly preferred at night. On the other hand, there are some studies suggesting the use of splint throughout the day. However, there is still no consensus. The aim of this randomized controlled study was to evaluate the effects of day and night splinting in terms of pain, symptom severity, functional status, and quality of life in patients with CTS. Results Seventy wrists of 46 patients with CTS were evaluated. In the day-night splint group, according to without splint group and night-only splint group, a statistically significant improvement was found in terms of pain level assessed by Visual Analogue Scale (p = 0.001, p = 0.015, respectively), Boston Carpal Tunnel Questionnaire-Functional Severity Scale (p = 0.004, p = 0.020, respectively), The Nottingham Health Profile-pain (p = 0.001, p = 0.003, respectively), The Nottingham Health Profile-social isolation (p = 0.001, p = 0.001, respectively), and The Nottingham Health Profile-total score (p = 0.001, p = 0.012, respectively). In addition, it was found that even the use of splint only at night resulted in a significant reduction in pain compared to the control group (p = 0.018). Conclusions Continuation of splinting as much as possible during the daytime in addition to night splinting is beneficial in terms of pain, nocturnal symptoms, functionality, and quality of life

    Infantile type Sandhoff disease with striking brain MRI findings and a novel mutation

    No full text
    BACKGROUND: Sandhoff disease is an autosomal recessive disorder caused by β-hexosaminidase deficiency in which the ganglioside GM2 and other glycolipids accumulate intracellularly within lysosomes. This process results in progressive motor neuron manifestations, death from respiratory failure and infections in infantiles. CASE REPORT: This report presents a 22-month-old girl with infantile type Sandhoff disease that was hospitalized for generalized seizures and psychomotor retardation. She was diagnosed with a genetically proven novel mutation and by demonstrating it's specific imaging findings. CONCLUSIONS: Determination of spesific changes in neuroimaging which are initial findings for GM2 gangliosidosis is important from the point of diagnosis and follow-up in infants suspected of having a neurodegenerative disease

    The prognostic value of gene expressions of ERCC1 and RRM1 in non-small cell lung cancer.

    No full text
    49th Annual Meeting of the American-Society-of-Clinical-Oncology (ASCO) -- MAY 31-JUN 04, 2013 -- Chicago, ILWOS: 000335419604603…Amer Soc Clin Onco

    Cross-reacting material 197 (CRM197) affects actin cytoskeleton of endothelial cells

    No full text
    WOS: 000412155000003PubMed ID: 28653650CRM197, cross-reacting material 197, is a mutant of diphtheria toxin (DTx). CRM197 is used in pharmacology as a carrier protein. It has been recently shown that CRM197 causes breakdown in actin filaments. In order to show intracellular localization of CRM197 and visualize cell structure via actin cytoskeleton, endothelial cells were cultured and subjected to CRM197 in vitro. To address the interaction between CRM197 and actin both experimental and theoretical studies were carried out. Colocalization of CRM197 with actin filaments was determined by immunofluorescence microscopy. Following 24-hour incubation, the loss of cell-cell contact between cells was prominent. CRM197 was shown to bind to G-actin by gel filtration chromatography, and this binding was confirmed by Western blot analysis of eluted samples obtained following chromatography. Based on crystal structure, docked model of CRM197-actin complex was generated. Molecular dynamics simulation revealed that Lys42, Cys218, Cys233 of CRM197 interacts with Gly197, Arg62 and Ser60 of G-actin, respectively. CRM197 binding to G-actin, colocalization of CRM197 with actin filament, and actin cytoskeleton rearrangement resulting in the loss of cell-cell contact show that actin comes into sight as target molecule for CRM197.Scientific Research Project Coordination Unit of Istanbul University [21270, 51249]This work was supported by the Scientific Research Project Coordination Unit of Istanbul University. Projects number: 21270 and 51249. We are thankful to Gamze Kilic Berkmen for her editing assistance

    Comparison of Different Diagnostic Methods in Detection of Residual Dentinal Caries

    No full text
    The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 µm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection
    corecore