18 research outputs found

    Effect of finishing technique on the occurrence and length of microcracks in resin-based materials

    Get PDF
    Purpose: To evaluate the presence and length of microcracks in resin-based materials finished with different techniques, using optical coherence tomography (OCT). Methods: Standardized Class V preparations (3×2×2mm) were made in the facial and lingual surfaces of 20 recently-extracted human third molars. 20 preparations were restored with a resin-based composite material (RBC; Filtek Supreme Ultra) and the other 20 with a resin modified glass-ionomer material (RMGI; Ketac Nano). After final polymerization, specimens were further stratified by finishing system: aluminum oxide discs (Sof-Lex) or spiral fluted carbide bur series (H48L). By random allocation, each extracted tooth therefore received one RBC and one RMGI restoration, and equal numbers of restorations from each material were finished using each finishing system (n= 10). After 24 hours of storage in 100% humidity at room temperature, the specimens were evaluated at ×20 to ×600 under environmental SEM. Cross-sectional occlusal-cervical B-mode images were obtained in increments of 25 mm from the mesial margin to the distal margin of the restoration using a spectral-domain (SD) OCT system and analyzed using Image J software to identify and measure microcrack penetration into each restoration. The total length (mm) at the point of the deepest microcrack penetration in each specimen was recorded. Data were statistically analyzed using a t-test. Results: No microcracks were observed in the RBC samples. However, microcrack presence was identified in all of the RMGI specimens. The t-test showed a statistically significant difference (P< 0.05) in mean microcrack length values based on the finishing technique used for the RMGI samples. [SofLex: 0.67 (Plusmn; 0.28) mm; carbide: 1.26 (Plusmn; 0.30)] mm. Two-way ANOVA showed significant differences in the factors "finishing technique" and "restorative material" (P< 0.001). The interaction of these two factors was also statistically significant (P< 0.001). For the tested RMGI, Tukey post-hoc test revealed that the finishing with aluminum oxide groups resulted in statistically significant lower mean microcrack length when compared to spiral fluted carbide burs (P< 0.001)

    The Science of Sungrazers, Sunskirters, and Other Near-Sun Comets

    Get PDF
    This review addresses our current understanding of comets that venture close to the Sun, and are hence exposed to much more extreme conditions than comets that are typically studied from Earth. The extreme solar heating and plasma environments that these objects encounter change many aspects of their behaviour, thus yielding valuable information on both the comets themselves that complements other data we have on primitive solar system bodies, as well as on the near-solar environment which they traverse. We propose clear definitions for these comets: We use the term near-Sun comets to encompass all objects that pass sunward of the perihelion distance of planet Mercury (0.307 AU). Sunskirters are defined as objects that pass within 33 solar radii of the Sun’s centre, equal to half of Mercury’s perihelion distance, and the commonly-used phrase sungrazers to be objects that reach perihelion within 3.45 solar radii, i.e. the fluid Roche limit. Finally, comets with orbits that intersect the solar photosphere are termed sundivers. We summarize past studies of these objects, as well as the instruments and facilities used to study them, including space-based platforms that have led to a recent revolution in the quantity and quality of relevant observations. Relevant comet populations are described, including the Kreutz, Marsden, Kracht, and Meyer groups, near-Sun asteroids, and a brief discussion of their origins. The importance of light curves and the clues they provide on cometary composition are emphasized, together with what information has been gleaned about nucleus parameters, including the sizes and masses of objects and their families, and their tensile strengths. The physical processes occurring at these objects are considered in some detail, including the disruption of nuclei, sublimation, and ionisation, and we consider the mass, momentum, and energy loss of comets in the corona and those that venture to lower altitudes. The different components of comae and tails are described, including dust, neutral and ionised gases, their chemical reactions, and their contributions to the near-Sun environment. Comet-solar wind interactions are discussed, including the use of comets as probes of solar wind and coronal conditions in their vicinities. We address the relevance of work on comets near the Sun to similar objects orbiting other stars, and conclude with a discussion of future directions for the field and the planned ground- and space-based facilities that will allow us to address those science topics

    In vitro bond strengths and SEM evaluation of dentin bonding systems to different dentin substrates

    Get PDF
    In comparison to enamel, bonding to normal dentin is a greater challenge because of its organic constituents, fluid-filed tubules, and variations in intrinsic composition. Bonding to sclerotic dentin is even more difficult. To evaluate the shear bond strengths of four adhesive systems to dentin substrates with different levels of mineralization, 120 extracted human teeth were randomly assigned to three groups (n = 40). After mid-coronal dentin was exposed, groups of specimens were artificially hypermineralized by immersion in a remineralizing solution, demineralized by means of an acetic acid demineralizing solution, or stored in distilled water to model sclerotic, carious, and normal dentin, respectively. Resin composite was bonded to dentin by use of commercial adhesive systems. After the specimens were thermocycled, shear bond strengths were determined in an Instron universal testing machine. Dentin substrates and resin/dentin interfaces were examined by SEM. For each adhesive system, the mean shear bond strength to normal dentin was significantly higher than that to either of the other substrates. Shear bond strengths to hypermineralized dentin were significantly higher than those to demineralized dentin with all adhesives except Prisma Universal Bond

    Microleakage of four different restorative glass ionomer formulations in Class V cavities: Er:YAG laser versus conventional preparation

    No full text
    Objective: To investigate microleakage in class V cavities following restoration with conventional glass-ionomer cements (CGICs) or resin-modified glass-ionomer cements (RMGICs), following Er:YAG laser or conventional preparation. Background Data: The sealing ability of GICs in Er:YAG-lased cavities has not been studied extensively. Methods: Three hundred and twenty class V cavities were assigned to four groups: those in groups A and B were prepared using an Er: YAG laser, and those in groups C and D were conventionally prepared. In groups B and D the surface was additionally conditioned with cavity conditioner. Each group was subdivided according to the GIC used: groups 1 (Fuji II), 2 (Fuji IX), 3 (Fuji II LC) and 4 ( Fuji VIII). After thermocycling, the specimens were immersed in a 2% methylene blue solution, sectioned oro-facially, and analyzed for leakage. The effect of the conditioner was analyzed using a scanning electron microscope (SEM). Results: Significant differences between occlusal and gingival margins were found in all groups (p < 0.05) except B4, D3, and D4. Comparison of preparation methods (groups A-D) revealed significant differences at the occlusal margin in groups 1 and 3, but in all groups at the gingival margin (p < 0.05). Laser preparation without conditioning allowed more leakage (p < 0.05). Comparison of filling materials (groups 1-4) revealed significant differences in groups B and C at the occlusal margin, and in all groups at the gingival margin (p < 0.05). In these groups, laser-prepared cavities (with or without conditioning) restored with Fuji II LC and Fuji VIII showed the least leakage at both margins. Conclusion: RMGICs allowed less microleakage than CGICs. Complete marginal sealing was not achieved and conditioning is recommended
    corecore