192 research outputs found

    A Preliminary Study on Flexible Temperature Sensors for Eskin Medical Devices

    Get PDF
    In the latest years, the need of a renewed paradigm for healthcare arose promoting the research towards the idea of remote diagnosis, care and monitoring of physiological parameters. Thus, the wearable and eskin devices arose to be embedded in the standard medical equipment. In this work, a preliminary study on flexible AJP-printed temperature sensors is reported in order to propose a novel approach to evaluate infection sites, monitor the body temperature and compensate the effects of temperature on other on-body sensors. Two different geometries are proposed, designed, produced, evaluated and compared. The results shown a similar dependance on temperature (average TCR = 2.5 ∙ 10 -3 °C-1) and the dependance on substrate deformation was enquired as well as the geometrical features of the sensors

    Peran Komisi Nasional Perlindungan Anak dalam Perlindungan Anak terhadap Kasus Kekerasan Seksual di DKI Jakarta Tahun 2014-2015

    Full text link
    DKI Jakarta is one of province in Indonesia which has highest number for sexual violence for kids in Indonesia, but DKI Jakarta Government has not been able to manage this problem yet. National Child Protection Commission is LSM which focuses in child protection that is caused of inoptimal Government in handling Child problems in sexual violence cases which every year the total cases are increasing. National Child Protection Commission has independent principle, public responsibility, sets the opportunity and chance out to the child in participating by respecting and taking side on child's basic principle.Method that isused in this research is qualitative research method by desrctiptive approach through direct monitoring in field and legal documents from Central Data and Information of National Child Protection Commission. Technique of data collecting by interviewing National Child Protection Commission and the victim's family of sexual violence which becomes National Child Protection Commission's client and monitoring, then it is analyzed qualitatively. Efforts from National Child Protection Commission in handling the victim of sexual violence consist of psychological service and advocation service.Results of this research shows that the existence of National Child Protection Commission has important role for its efforts in sexual violence for child protection in DKI Jakarta though there is still perceived less optimal which is caused of obstacles and limits which are had and faced by National Child Protection Commission. This research also take an important role in role of child protection in National scale

    preliminary study of inkjet printed sensors for monitoring cell cultures

    Get PDF
    Abstract An extremely promising methodology able to obtain feedbacks from cell cultures is represented by the direct integration within culture substrates of specific sensitive elements capable to provide information related to cell adhesion, migration, differentiation and growth. At present, the most common materials used in the implementation of sensors monitoring 2D cell culture are noble metals. However, printed electronics allow instead an innovative approach, from both sensor realization technique and utilization of sensitive materials. This project aims to develop and test 2D ink-jet printed sensors, focusing on biocompatible substrates and conductive inks. Both biocompatibility and printability of two different sensor designs were evaluated, followed by electronic measurements that estimate fibroblast adhesion. Preliminary findings show a good biocompatibility of the KaptonÂź substrate coupled with PEDOT:PSS ink. This solution allowed us to correlate cell adhesion with an increase of impedance module, in agreement with the optical observation. On-going works rely on the evaluation of different materials used for both substrates and inks, addressing the possibility to monitor cardiomyocyte activity

    Smart Brace for Static and Dynamic Knee Laxity Measurement

    Get PDF
    Every year in Europe more than 500 thousand injuries that involve the anterior cruciate ligament (ACL) are diagnosed. The ACL is one of the main restraints within the human knee, focused on stabilizing the joint and controlling the relative movement between the tibia and femur under mechanical stress (i.e., laxity). Ligament laxity measurement is clinically valuable for diagnosing ACL injury and comparing possible outcomes of surgical procedures. In general, knee laxity assessment is manually performed and provides information to clinicians which is mainly subjective. Only recently quantitative assessment of knee laxity through instrumental approaches has been introduced and become a fundamental asset in clinical practice. However, the current solutions provide only partial information about either static or dynamic laxity. To support a multiparametric approach using a single device, an innovative smart knee brace for knee laxity evaluation was developed. Equipped with stretchable strain sensors and inertial measurement units (IMUs), the wearable system was designed to provide quantitative information concerning the drawer, Lachman, and pivot shift tests. We specifically characterized IMUs by using a reference sensor. Applying the Bland–Altman method, the limit of agreement was found to be less than 0.06 m/s2 for the accelerometer, 0.06 rad/s for the gyroscope and 0.08 ÎŒT for the magnetometer. By using an appropriate characterizing setup, the average gauge factor of the three strain sensors was 2.169. Finally, we realized a pilot study to compare the outcomes with a marker-based optoelectronic stereophotogrammetric system to verify the validity of the designed system. The preliminary findings for the capability of the system to discriminate possible ACL lesions are encouraging; in fact, the smart brace could be an effective support for an objective and quantitative diagnosis of ACL tear by supporting the simultaneous assessment of both rotational and translational laxity. To obtain reliable information about the real effectiveness of the system, further clinical validation is necessary

    Screen-Printed Biosensors for the Early Detection of Biomarkers Related to Alzheimer Disease: Preliminary Results

    Get PDF
    Abstract Alzheimer disease (AD), despite representing the most common type of dementia in elderly, is still lacking reliable methodologies for early diagnosis. A potential biomarker associated to AD development has been recently identified in the open isoform of p53, redox sensitive protein, currently quantified using a specific blood-based enzyme-linked immunosorbent assay (ELISA). In order to overcome ELISA limitations (level of detection, standardization and reliability), this study aimed to realize a low cost highly sensitive portable point-of-care (PoC) testing system based on screen printed electrochemical sensors (SPES). The study specifically reported the design of the platform, including the sensing probe and the electronic circuit devoted to the conditioning of the electric signal. Preliminary results were obtained from circuit testing by using controlled concentrations of electrolytic solutions and from an initial calibration stage by using Anodic Stripping Voltammetry (ASV) measurements. Future works will address the quantification of unknown concentration of unfolded p53 in peripheral blood samples, thus to validate the here-presented low cost, easy to use and highly precise platform

    Flat Type Thick Film Inductive Sensors

    Get PDF
    Two thick film flat-type inductive sensors are described and tested for distance and profile measurement. The first one is a single-layer spiral while the second one is a multi-layer structure consisting of ten spirals one over the other. The paper describes their geometric configurations together with their simulated magnetic fields and it reports the results from the characterization test i.e. the series-equivalent circuit parameters, the sensitivity and the cross-sensitivity to temperature. An experimental analysis of the sensitivity suggests that optimized values are obtained by an appropriate choice of the working frequency. The sensors are shielded against e.m. noise coming from the nonsensitive area. Moreover, two sensors have been tested in the laboratory using the single layer as a distance sensor and the multi-layer as a transducer for the measurement of a metallic object profile. The results of the tests show a maximum sensitivity of 14mV/”m and a resolution of 0.6 ”m for the single layer, while the multi layer one reconstructs the profile with an axial resolution of a few microns and a lateral resolution better than 200 mm

    Comparison of phosphor screen autoradiography and micro-pattern gas detector based autoradiography for the porosity of altered rocks

    Get PDF
    This study aims to further develop the C-14-PMMA porosity calculation method with a novel autoradiography technique, the Micro-pattern gas detector autoradiography (MPGDA). In this study, the MPGDA is compared with phosphor screen autoradiography (SPA). A set of rock samples from Martinique Island exhibiting a large range of connected porosities was used to validate the MPGDA method. Calculated porosities were found to be in agreement with ones from the SPA and the triple-weight method (TW). The filmless nature of MPGDA as well as straightforward determination of C-14 radioactivity from the source rock makes the porosity calculation less uncertain. The real-time visualization of radioactivity from C-14 beta emissions by MPGDA is a noticeable improvement in comparison to SPA.Peer reviewe

    Petrophysics of Chicxulub Impact Crater's Peak Ring

    Get PDF
    A new set of physical property measurements was undertaken on 29 peak-ring samples from the IODP-ICDP Expedition 364. Among the studied lithologies, the dominant one recovered in the peak ring consists of shocked granitoid rocks (19 samples). Porosity measurements with two independent methods (triple weight and C-14-PMMA porosity mapping) concur and bring new observations on the intensity and distribution of fracturing and porosity in these shocked target rocks. Characterization of the porous network is taken a step further with two other independent methods (electrical and permeability measurements). Electrical properties such as the cementation exponent (1.59 m < 1.87) and the formation factor (21 F < 103) do not compare with other granites from the published literature; they point at a type of porosity closer to clastic sedimentary rocks than to crystalline rocks. Permeabilities of the granitoid rocks range from 0.1 to 7.1 mD under an effective pressure of similar to 10 MPa. Unlike other fresh to deformed and altered granitoid rocks from the literature compared in this study, this permeability appears to be relatively insensitive to increasing stress (up to similar to 40 MPa), with implications for the nature of the porous network, again, behaving more like cemented clastic rocks than fractured crystalline rocks. Other analyzed lithologies include suevite and impact melt rocks. Relatively low permeability (10(-3) mD) measured in melt-rich facies suggest that, at the matrix scale, these lithologies cutting through more permeable peak-ring granitoid rocks may have been a barrier to fluid flow, with implications for hydrothermal systems.Peer reviewe
    • 

    corecore