84 research outputs found

    X-ray detection with a scintillating YAP-window hybrid photomultiplier tube

    Get PDF
    A YAP(YAlO/sub 3/:Ce)-scintillating window, coated on its inner surface with an S20-photocathode, seals a cross-focusing hybrid photomultiplier tube (HPMT) equipped with a small p-i-n anode of 2-mm diameter. This new radiation detector separates X-ray lines down to about 2-keV peak energy from the HPMT noise. Its detection efficiency for high gamma energies depends on the YAP-window thickness and amounts to about 18% attenuation at 400-keV energy in the present version. Competitive radiation detectors like Si photodiodes and Si drift chambers are discussed and compared to our prototype, with particular attention given to their energy resolution and noise performance, which limits their active area considerably. (19 refs)

    A HPMT based set-up to characterize scintillating crystals

    Get PDF
    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a Hybrid Photomultiplier Tube especially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the Lead Tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN

    Effect of surface roughness and sterilization on bacterial adherence to ultra-high molecular weight polyethylene

    Get PDF
    AbstractSterilization with ethylene oxide (EO) and gas plasma (GP) are well-known methods applied to ultra-high molecular weight polyethylene (UHMWPE) surfaces in the belief that they prevent major material changes caused by gamma irradiation. However, the influence of these surface sterilization methods on bacterial adherence to UHMWPE is unknown. UHMWPE samples with various degrees of roughness (0.3, 0.8 and 2.0 µm) were sterilized with either GP or EO. The variations in hydrophobicity, surface free energy and surface functional groups were investigated before and after sterilization. Sterilized samples were incubated with either Staphylococcus aureus or Staphylococcus epidermidis in order to study bacterial adherence to these materials. Fewer bacteria adhered to UHMWPE after sterilization with EO than after sterilization with GP, especially to the smoothest surfaces. No changes in chemical composition of the UHMWPE surface due to sterilization were observed using X-ray photoemission spectroscopy analysis. The decreased bacterial adherence to UHMWPE found at the smoothest surfaces after sterilization with EO was not directly related to changes in chemical composition. Increased bacterial adherence to rougher surfaces was associated with increased polar surface energy of EO-sterilized surfaces

    Polyethylene Oxidation in Total Hip Arthroplasty: Evolution and New Advances

    Get PDF
    Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs

    Knee model of hydrodynamic lubrication during the gait cycle and the influence of prosthetic joint conformity

    No full text
    Background: The influence of the total joint components' elastic deformation on lubrication is generally accepted, but little is known about the influence of joint conformity under hydrodynamic lubrication based on fluid film interposition. The aim of this study was to evaluate induced pressure and stresses in the knee under fluid film lubrication during the stance phase of walking under various joint conformity conditions. Methods: A theoretical two-dimensional (2D) geometric model of knee prosthesis contact, with Dirichlet boundary conditions at both edges, and with a conformity index (CI) of 0, 0.3, 0.5, 0.6, 0.7, 0.8, 0.9, 0.92, 0.94, 0.96, 0.98, 0.99, 0.995, and 1.0, was used to calculate the spatiotemporal lubricant flow on a synovial fluid rheological model. With the instantaneous load as a source term, the Reynolds lubrication equation was subsequently solved following a finite volume approach in two dimensions and three dimensions. Results: Conformity strongly influenced the peak pressure, from 47 MPa with CI = 0 to 1.4 MPa with CI = 1, with a definite behavior change from CI = 0.96. The role of hydrodynamic lubrication was restricted to early steps of the stance phase. With CI 0.96. Conclusion: The present model suggested the limited modifying effect of hydrodynamic lubrication in total knee replacement systems. However, its role during the early stance phase, coupled with high conformity, helps significantly to decrease compressive stresses on the polyethylene, fostering the beneficial effect of high conformity in a mixed lubrication regime. This beneficial effect may also be of great interest in total knee replacement systems based on materials with less deformation. © 2009 The Japanese Orthopaedic Association.Peer Reviewe

    Crystalline YAlO3YAlO_{3} as a novel window for photodetectors

    No full text
    Pure crystalline YAlO/sub 3/ can be applied due to its high refractive index as a novel material for optical elements within 240-1000 nm light transmission. If used as front-windows for photon detectors and coated with a photocathode at its vacuum interface, it improves their light collection efficiency. Its high refractive index increases the numerical aperture of lenses and hence their spatial resolving power. It matches favorably with the refractive index of Mg F/sub 2/, which used as antireflection coating reduces the surface reflectance close to zero. Doped with Ce/sup 3+/-ions, YAlO/sub 3 /(Ce) can be readily used as scintillating front windows of vacuum- sealed photon detectors for ionizing radiation. (9 refs)

    Two potato (Solanum tuberosum) varieties differ in drought tolerance due to differences in root growth at depth

    No full text
    To test the hypothesis that root growth at depth is a key trait explaining some genotypic differences in drought tolerance in potato (Solanum tuberosum L.), two varieties (Horizon and Maris Piper) differing in drought tolerance were subjected to different irrigation regimes in pots in a glasshouse and in the field under a polytunnel. In the glasshouse, both cultivars showed similar gas exchange, leaf water potential, leaf xylem ABA concentration and shoot biomass independently of whether plants were grown under well watered or water deficit conditions. Under well watered conditions, root growth was three-fold higher in Horizon compared with Maris Piper, 3 weeks after emergence. Water deficit reduced this difference. In the polytunnel, applying 60% or less irrigation volume compared with full irrigation significantly decreased tuber yield in Maris Piper but not in Horizon. This was coincident with the higher root density of Horizon in deep soil layers (>40 cm), where water content was stable. The results suggest that early vigorous root proliferation may be a useful selection trait for maintaining yield of potato under restricted irrigation or rainfall, because it rapidly secures access to water stored in deep soil layers. Although selecting for vigorous root growth may assist phenotyping screening for drought tolerance, these varieties may require particular environmental or cultural conditions to express root vigour, such as sufficiently deep soils or sufficient water shortly after emergence
    corecore