    Assessment of neonatal respiratory rate variability

    Get PDF
    Accurate measurement of respiratory rate (RR) in neonates is challenging due to high neonatal RR variability (RRV). There is growing evidence that RRV measurement could inform and guide neonatal care. We sought to quantify neonatal RRV during a clinical study in which we compared multiparameter continuous physiological monitoring (MCPM) devices. Measurements of capnography-recorded exhaled carbon dioxide across 60-s epochs were collected from neonates admitted to the neonatal unit at Aga Khan University-Nairobi hospital. Breaths were manually counted from capnograms and using an automated signal detection algorithm which also calculated mean and median RR for each epoch. Outcome measures were between- and within-neonate RRV, between- and within-epoch RRV, and 95% limits of agreement, bias, and root-mean-square deviation. Twenty-seven neonates were included, with 130 epochs analysed. Mean manual breath count (MBC) was 48 breaths per minute. Median RRV ranged from 11.5% (interquartile range (IQR) 6.8–18.9%) to 28.1% (IQR 23.5–36.7%). Bias and limits of agreement for MBC vs algorithm-derived breath count, MBC vs algorithm-derived median breath rate, MBC vs algorithm-derived mean breath rate were − 0.5 (− 2.7, 1.66), − 3.16 (− 12.12, 5.8), and − 3.99 (− 11.3, 3.32), respectively. The marked RRV highlights the challenge of performing accurate RR measurements in neonates. More research is required to optimize the use of RRV to improve care. When evaluating MCPM devices, accuracy thresholds should be less stringent in newborns due to increased RRV. Lastly, median RR, which discounts the impact of extreme outliers, may be more reflective of the underlying physiological control of breathing

    Evaluation of Sibel’s Advanced Neonatal Epidermal (ANNE) wireless continuous physiological monitor in Nairobi, Kenya

    Get PDF
    Background: Neonatal multiparameter continuous physiological monitoring (MCPM) technologies assist with early detection of preventable and treatable causes of neonatal mortality. Evaluating accuracy of novel MCPM technologies is critical for their appropriate use and adoption. Methods: We prospectively compared the accuracy of Sibel’s Advanced Neonatal Epidermal (ANNE) technology with Masimo’s Rad-97 pulse CO-oximeter with capnography and Spengler’s Tempo Easy reference technologies during four evaluation rounds. We compared accuracy of heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and skin temperature using Bland-Altman plots and root-mean-square deviation analyses (RMSD). Sibel’s ANNE algorithms were optimized between each round. We created Clarke error grids with zones of 20% to aid with clinical interpretation of HR and RR results. Results: Between November 2019 and August 2020 we collected 320 hours of data from 84 neonates. In the final round, Sibel’s ANNE technology demonstrated a normalized bias of 0% for HR and 3.1% for RR, and a non-normalized bias of -0.3% for SpO2 and 0.2°C for temperature. The normalized spread between 95% upper and lower limits-of-agreement (LOA) was 4.7% for HR and 29.3% for RR. RMSD for SpO2 was 1.9% and 1.5°C for temperature. Agreement between Sibel’s ANNE technology and the reference technologies met the a priori-defined thresholds for 95% spread of LOA and RMSD. Clarke error grids showed that all HR and RR observations were within a 20% difference. Conclusion: Our findings suggest acceptable agreement between Sibel’s ANNE and reference technologies. Clinical effectiveness, feasibility, usability, acceptability, and cost-effectiveness investigations are necessary for large-scale implementation

    Evaluation of a contactless neonatal physiological monitor in Nairobi, Kenya

    Get PDF
    Background: Globally, 2.5 million neonates died in 2018, accounting for 46% of under-5 deaths. Multiparameter continuous physiological monitoring (MCPM) of neonates allows for early detection and treatment of life-threatening health problems. However, neonatal monitoring technology is largely unavailable in low-resource settings. Methods: In four evaluation rounds, we prospectively compared the accuracy of the EarlySense under-mattress device to the Masimo Rad-97 pulse CO-oximeter with capnography reference device for heart rate (HR) and respiratory rate (RR) measurements in neonates in Kenya. EarlySense algorithm optimisations were made between evaluation rounds. In each evaluation round, we compared 200 randomly selected epochs of data using Bland-Altman plots and generated Clarke error grids with zones of 20% to aid in clinical interpretation. Results: Between 9 July 2019 and 8 January 2020, we collected 280 hours of MCPM data from 76 enrolled neonates. At the final evaluation round, the EarlySense MCPM device demonstrated a bias of -0.8 beats/minute for HR and 1.6 breaths/minute for RR, and normalised spread between the 95% upper and lower limits of agreement of 6.2% for HR and 27.3% for RR. Agreement between the two MCPM devices met the a priori-defined threshold of 30%. The Clarke error grids showed that all observations for HR and 197/200 for RR were within a 20% difference. Conclusion: Our research indicates that there is acceptable agreement between the EarlySense and Masimo MCPM devices in the context of large within-subject variability; however, further studies establishing cost-effectiveness and clinical effectiveness are needed before large-scale implementation of the EarlySense MCPM device in neonates

    Clinical feasibility of a contactless multiparameter continuous monitoring technology for neonates in a large public maternity hospital in Nairobi, Kenya

    Get PDF
    Multiparameter continuous physiological monitoring (MCPM) technologies are critical in the clinical management of high-risk neonates; yet, these technologies are frequently unavailable in many African healthcare facilities. We conducted a prospective clinical feasibility study of EarlySense’s novel under-mattress MCPM technology in neonates at Pumwani Maternity Hospital in Nairobi, Kenya. To assess feasibility, we compared the performance of EarlySense’s technology to Masimo’s Rad-97 pulse CO-oximeter with capnography technology for heart rate (HR) and respiratory rate (RR) measurements using up-time, clinical event detection performance, and accuracy. Between September 15 and December 15, 2020, we collected and analyzed 470 hours of EarlySense data from 109 enrolled neonates. EarlySense’s technology’s up-time per neonate was 2.9 (range 0.8, 5.3) hours for HR and 2.1 (range 0.9, 4.0) hours for RR. The difference compared to the reference was a median of 0.6 (range 0.1, 3.1) hours for HR and 0.8 (range 0.1, 2.9) hours for RR. EarlySense’s technology identified high HR and RR events with high sensitivity (HR 81%; RR 83%) and specificity (HR 99%; RR 83%), but was less sensitive for low HR and RR (HR 0%; RR 14%) although maintained specificity (HR 100%; RR 95%). There was a greater number of false negative and false positive RR events than false negative and false positive HR events. The normalized spread of limits of agreement was 9.6% for HR and 28.6% for RR, which met the a priori-identified limit of 30%. EarlySense’s MCPM technology was clinically feasible as demonstrated by high percentage of up-time, strong clinical event detection performance, and agreement of HR and RR measurements compared to the reference technology. Studies in critically ill neonates, assessing barriers and facilitators to adoption, and costing analyses will be key to the technology’s development and potential uptake and scale-up

    Moving beyond silos: How do we provide distributed personalized medicine to pregnant women everywhere at scale? Insights from PRE-EMPT.

    Get PDF
    While we believe that pre-eclampsia matters-because it remains a leading cause of maternal and perinatal morbidity and mortality worldwide-we are convinced that the time has come to look beyond single clinical entities (e.g. pre-eclampsia, postpartum hemorrhage, obstetric sepsis) and to look for an integrated approach that will provide evidence-based personalized care to women wherever they encounter the health system. Accurate outcome prediction models are a powerful way to identify individuals at incrementally increased (and decreased) risks associated with a given condition. Integrating models with decision algorithms into mobile health (mHealth) applications could support community and first level facility healthcare providers to identify those women, fetuses, and newborns most at need of facility-based care, and to initiate lifesaving interventions in their communities prior to transportation. In our opinion, this offers the greatest opportunity to provide distributed individualized care at scale, and soon

    Semantic zoom view: a focus+context technique for visualizing a document collection

    Get PDF
    In the field of visual analytics, analysts need overviews of large amounts of data. This becomes a challenge when working with non-numerical data such as document collections. This thesis describes the design and use of a new visualization technique called Semantic Zoom View (SZV), which provides an interactive overview of a document collection combined with a detailed view of entities contained in the documents (people, places, etc.) and full text of each document. SZV lets analysts easily and quickly see the main topics of a document collection. Any subset of documents can be semantically zoomed to show increasing detail as the zoom level increases, while keeping surrounding documents visible to supply context. This tight integration of focus within context encourages and facilitates the iterative process of finding relevant documents and reading them. An evaluation compares the described technique to an overview+detail technique for finding answers within a document collection

    Variability of respiratory rate measurements in neonates- every minute counts

    Get PDF
    Background Respiratory rate is difficult to measure, especially in neonates who have an irregular breathing pattern. The World Health Organisation recommends a one-minute count, but there is limited data to support this length of observation. We sought to evaluate agreement between the respiratory rate (RR) derived from capnography in neonates, over 15 s, 30 s, 120 s and 300 s, against the recommended 60 s. Methods Neonates at two hospitals in Nairobi were recruited and had capnograph waveforms recorded using the Masimo Rad 97. A single high quality 5 min epoch was randomly chosen from each subject. For each selected epoch, the mean RR was calculated using a breath-detection algorithm applied to the waveform. The RR in the first 60 s was compared to the mean RR measured over the first 15 s, 30 s, 120 s, full 300 s, and last 60 s. We calculated bias and limits of agreement for each comparison and used Bland-Altman plots for visual comparisons. Results A total of 306 capnographs were analysed from individual subjects. The subjects had a median gestation age of 39 weeks with slightly more females (52.3%) than males (47.7%). The majority of the population were term neonates (70.1%) with 39 (12.8%) having a primary respiratory pathology. There was poor agreement between all the comparisons based on the limits of agreement [confidence interval], ranging between 11.9 [− 6.79 to 6.23] breaths per minute in the one versus 2 min comparison, and 34.7 [− 17.59 to 20.53] breaths per minute in the first versus last minute comparison. Worsening agreement was observed in plots with higher RRs. Conclusions Neonates have high variability of RR, even over a short period of time. A slight degradation in the agreement is noted over periods shorter than 1 min. However, this is smaller than observations done 3 min apart in the same subject. Longer periods of observation also reduce agreement. For device developers, precise synchronization is needed when comparing devices to reduce the impact of RR variation. For clinicians, where possible, continuous or repeated monitoring of neonates would be preferable to one time RR measurements.Medicine, Faculty ofOther UBCReviewedFacultyResearche
    • …