728 research outputs found

    Validation of Stratospheric and Mesospheric Ozone Observed by SMILES from International Space Station

    Get PDF
    We observed ozone O3 in the vertical region between 250 and 0.0005 hPa (~ 12-96 km) using the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES) on the Japanese Experiment Module (JEM) of the International Space Station (ISS) between 12 October 2009 and 21 April 2010. The new 4K superconducting heterodyne receiver technology of SMILES allowed us to obtain a one order of magnitude better signal-to-noise ratio for the O3 line observation compared to past spaceborne microwave instruments. The non-sun-synchronous orbit of the ISS allowed us to observe O3 at various local times. We assessed the quality of the vertical profiles of O3 in the 100-0.001 hPa (~ 16-90 km) region for the SMILES NICT Level 2 product version 2.1.5. The evaluation is based on four components: error analysis; internal comparisons of observations targeting three different instrumental setups for the same O3 625.371 GHz transition; internal comparisons of two different retrieval algorithms; and external comparisons for various local times with ozonesonde, satellite and balloon observations (ENVISAT/MIPAS, SCISAT/ACE-FTS, Odin/OSIRIS, Odin/SMR, Aura/MLS, TELIS). SMILES O3 data have an estimated absolute accuracy of better than 0.3 ppmv (3%) with a vertical resolution of 3-4 km over the 60 to 8 hPa range. The random error for a single measurement is better than the estimated systematic error, being less than 1, 2, and 7%, in the 40-1, 80-0.1, and 100-0.004 hPa pressure regions, respectively. SMILES O-3 abundance was 10-20% lower than all other satellite measurements at 8-0.1 hPa due to an error arising from uncertainties of the tangent point information and the gain calibration for the intensity of the spectrum. SMILES O3 from observation frequency Band-B had better accuracy than that from Band-A. A two month period is required to accumulate measurements covering 24 h in local time of O3 profile. However such a dataset can also contain variation due to dynamical, seasonal, and latitudinal effects

    THE HAWAII INFRARED PARALLAX PROGRAM. II. YOUNG ULTRACOOL FIELD DWARFS

    Get PDF
    (Abridged) We present a large, uniform analysis of young (~10-150 Myr) ultracool dwarfs, based on new high-precision IR parallaxes for 68 objects. We find that low-gravity (VL-G) late-M and L dwarfs form a continuous sequence in IR color-magnitude diagrams, separate from field objects and current theoretical models. VL-G objects also appear distinct from young substellar (brown dwarf and exoplanet) companions, suggesting the two populations have a different range of physical properties. In contrast, at the L/T transition, young, old, and peculiar objects all span a narrow range in near-IR absolute magnitudes. At a given spectral type, the IR absolute magnitudes of young objects can be offset from ordinary field dwarfs, with the largest offsets occurring in the Y and J bands for late-M dwarfs (brighter than the field) and mid/late-L dwarfs (fainter than the field). Overall, low-gravity (VL-G) objects have the most uniform photometric behavior while intermediate-gravity (INT-G) objects are more diverse, suggesting a third governing parameter beyond spectral type and gravity class. We examine the moving group memberships for all young ultracool dwarfs with parallaxes, changing/refuting the status of 23 objects and fortifying the status of another 28 objects. We use our resulting age-calibrated sample to establish empirical young isochrones and find a declining frequency of VL-G objects relative to INT-G objects with increasing age. Notable objects in our sample include high-velocity INT-G objects; very red, late-L dwarfs with high surface gravities; candidate disk-bearing members of the MBM20 cloud and beta Pic moving group; and very young distant interlopers. Finally, we provide a comprehensive summary of the absolute magnitudes and spectral classifications of 102 young ultracool dwarfs, found in the field and as substellar companions to young stars.Comment: ApJ, in press, 138 pages including 33 figures and 15 tables. Compilation of young ultracool dwarfs and young substellar (brown dwarf and exoplanet) companions available at the Database of Ultracool Parallaxes (see http://www.as.utexas.edu/~tdupuy/plx

    Impact of acute partial-body cryostimulation on cognitive performance, cerebral oxygenation, and cardiac autonomic activity

    Get PDF
    We assessed the effects of a 3-min partial-body cryostimulation (PBC) exposure -where the whole body is exposed to extreme cold, except the head- on cognitive inhibition performance and the possible implications of parasympathetic cardiac control and cerebral oxygenation. In a randomized controlled counterbalanced cross-over design, eighteen healthy young adults (nine males and nine females) completed a cognitive Stroop task before and after one single session of PBC (3-min exposure at -150ÂșC cold air) and a control condition (3 minutes at room temperature, 20ÂșC). During the cognitive task, heart rate variability (HRV) and cerebral oxygenation of the prefrontal cortex were measured using heart rate monitoring and near-infrared spectroscopy methods. We also recorded the cerebral oxygenation during the PBC session. Stroop performance after PBC exposure was enhanced (562.0 ± 40.2 ms) compared to pre-PBC (602.0 ± 56.4 ms; P < 0.042) in males only, accompanied by an increase (P < 0.05) in HRV indices of parasympathetic tone, in greater proportion in males compared to females. During PBC, cerebral oxygenation decreased in a similar proportion in males and females but the cerebral extraction (deoxyhemoglobin: ΔHHb) remained higher after exposure in males, only. These data demonstrate that a single PBC session enhances the cognitive inhibition performance on a Stroop task in males, partly mediated by a greater parasympathetic cardiac control and greater cerebral oxygenation. The effects of PBC on cognitive function seem different in females, possibly explained by a different sensitivity to cold stimulation

    Comparison of SMILES ClO profiles with satellite, balloon-borne and ground-based measurements

    Get PDF
    We evaluate the quality of ClO profiles derived from the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES) on the International Space Station (ISS). Version 2.1.5 of the level-2 product generated by the National Institute of Information and Communications Technology (NICT) is the subject of this study. Based on sensitivity studies, the systematic error was estimated as 5–10 pptv at the pressure range of 80–20 hPa, 35 pptv at the ClO peak altitude (~ 4 hPa), and 5–10 pptv at pressures ≀ 0.5 hPa for daytime mid-latitude conditions. For nighttime measurements, a systematic error of 8 pptv was estimated for the ClO peak altitude (~ 2 hPa). The SMILES NICT v2.1.5 ClO profiles agree with those derived from another level-2 processor developed by the Japan Aerospace Exploration Agency (JAXA) within the bias uncertainties, except for the nighttime measurements in the low and middle latitude regions where the SMILES NICT v2.1.5 profiles have a negative bias of ~ 30 pptv in the lower stratosphere. This bias is considered to be due to the use of a limited spectral bandwidth in the retrieval process of SMILES NICT v2.1.5, which makes it difficult to distinguish between the weak ClO signal and wing contributions of spectral features outside the bandwidth. In the middle and upper stratosphere outside the polar regions, no significant systematic bias was found for the SMILES NICT ClO profile with respect to data sets from other instruments such as the Aura Microwave Limb Sounder (MLS), the Odin Sub-Millimetre Radiometer (SMR), the Envisat Michelson Interferometer for Passive Atmospheric Sounding (MIPAS), and the ground-based radiometer at Mauna Kea, which demonstrates the scientific usability of the SMILES ClO data including the diurnal variations. Inside the chlorine-activated polar vortex, the SMILES NICT v2.1.5 ClO profiles show larger volume mixing ratios by 0.4 ppbv (30%) at 50 hPa compared to those of the JAXA processed profiles. This discrepancy is also considered to be an effect of the limited spectral bandwidth in the retrieval processing. We also compared the SMILES NICT ClO profiles of chlorine-activated polar vortex conditions with those measured by the balloon-borne instruments: Terahertz and submillimeter Limb Sounder (TELIS) and the MIPAS-balloon instrument (MIPAS-B). In conclusion, the SMILES NICT v2.1.5 ClO data can be used at pressures ≀ ~30 hPa for scientific analysis

    Antitumour necrosis factor-α therapy for hidradenitis suppurativa: results from a national cohort study between 2000 and 2013

    Get PDF
    International audienceHidradenitis suppurativa (HS) is a frequent chronic inflammatory skin disease typically characterized by recurrent painful, deep inflammatory nodules of the axillary, breast, groin and gluteal areas. European recommendations are mainly based on expert opinion. Drug treatments are heterogenous (e.g., antibiotics, corticosteroids, retinoids) and lack consensus among expert centres. The most severe disease forms or those failing to respond to conventional drugs may be associated with worsened functional prognosis. Anti-tumor necrosis factor α (anti-TNFα) drugs have been prescribed in these cases. The results of randomized controlled trials (RCTs) are discordant. Three RCTs concluded to the efficacy of adalimumab (ADA), and two others did not detect any difference between infliximab (IFX) or etanercept (ETA) and placebo. Finally, data from the literature and reported experiences do not conclude on the efficacy of anti-TNFα drugs for HS. This article is protected by copyright. All rights reserve

    Strain-gradient position mapping of semiconductor quantum dots

    Get PDF
    COORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESWe introduce a nondestructive method to determine the position of randomly distributed semiconductor quantum dots (QDs) integrated in a solid photonic structure. By setting the structure in an oscillating motion, we generate a large stress gradient across the QDs plane. We then exploit the fact that the QDs emission frequency is highly sensitive to the local material stress to map the position of QDs deeply embedded in a photonic wire antenna with an accuracy ranging from +/- 35 nm down to +/- 1 nm. In the context of fast developing quantum technologies, this technique can be generalized to different photonic nanostructures embedding any stress-sensitive quantum emitters.1181116COORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESCOORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPES88887.059630/2014-00The authors wish to thank E. Gautier for the FIB cut and images. Sample fabrication was carried out in the Upstream Nanofabrication Facility (PTA) and CEA LETI MINATEC/DOPT clean rooms. P.-L. de Assis was financially supported by Agence Nationale de la Recherche (Project No. ANR-11-BS10-011) and CAPES Young Talents Fellowship Grant No. 88887.059630/2014-00, and D. Tumanov by a doctoral scholarship from the Rhîne-Alpes Region

    The Level 2 research product algorithms for the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES)

    Get PDF
    This paper describes the algorithms of the level-2 research (L2r) processing chain developed for the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES). The chain has been developed in parallel to the operational chain for conducting researches on calibration and retrieval algorithms. L2r chain products are available to the scientific community. The objective of version 2 is the retrieval of the vertical distribution of trace gases in the altitude range of 18–90 km. A theoretical error analysis is conducted to estimate the retrieval feasibility of key parameters of the processing: line-of-sight elevation tangent altitudes (or angles), temperature and ozone profiles. While pointing information is often retrieved from molecular oxygen lines, there is no oxygen line in the SMILES spectra, so the strong ozone line at 625.371 GHz has been chosen. The pointing parameters and the ozone profiles are retrieved from the line wings which are measured with high signal to noise ratio, whereas the temperature profile is retrieved from the optically thick line center. The main systematic component of the retrieval error was found to be the neglect of the non-linearity of the radiometric gain in the calibration procedure. This causes a temperature retrieval error of 5–10 K. Because of these large temperature errors, it is not possible to construct a reliable hydrostatic pressure profile. However, as a consequence of the retrieval of pointing parameters, pressure induced errors are significantly reduced if the retrieved trace gas profiles are represented on pressure levels instead of geometric altitude levels. Further, various setups of trace gas retrievals have been tested. The error analysis for the retrieved HOCl profile demonstrates that best results for inverting weak lines can be obtained by using narrow spectral windows

    Use of quercetin in animal feed : effects on the P-gp expression and pharmacokinetics of orally administrated enrofloxacin in chicken

    Get PDF
    Modulation of P-glycoprotein (P-gp, encoded by Mdr1) by xenobiotics plays central role in pharmacokinetics of various drugs. Quercetin has a potential to modulate P-gp in rodents, however, its effects on P-gp modulation in chicken are still unclear. Herein, study reports role of quercetin in modulation of P-gp expression and subsequent effects on the pharmacokinetics of enrofloxacin in broilers. Results show that P-gp expression was increased in a dose-dependent manner following exposure to quercetin in Caco-2 cells and tissues of chicken. Absorption rate constant and apparent permeability coefficient of rhodamine 123 were decreased, reflecting efflux function of P-gp in chicken intestine increased by quercetin. Quercetin altered pharmacokinetic of enrofloxacin by decreasing area under curve, peak concentration, and time to reach peak concentration and by increasing clearance rate. Molecular docking shows quercetin can form favorable interactions with binding pocket of chicken xenobiotic receptor (CXR). Results provide convincing evidence that quercetin induced P-gp expression in tissues by possible interaction with CXR, and consequently reducing bioavailability of orally administered enrofloxacin through restricting its intestinal absorption and liver/kidney clearance in broilers. The results can be further extended to guide reasonable use of quercetin to avoid drug-feed interaction occurred with co-administered enrofloxacin or other similar antimicrobials.Peer reviewedFinal Published versio

    Acute myocardial infarction in a patient with hypofibrinogenemia: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Congenital fibrinogen deficiency is a rare coagulation disorder usually responsible for hemorrhagic diathesis. However, it can be associated with thrombosis and there have been limited reports of arterial thrombotic complications in these patients.</p> <p>Case presentation</p> <p>A 42-year-old Tunisian man with congenital hypofibrinogenemia and no cardiovascular risk factors presented with new onset prolonged angina pectoris. An electrocardiogram showed features of inferior acute myocardial infarction. His troponin levels had reached 17 ng/L. Laboratory findings confirmed hypofibrinogenemia and ruled out thrombophilia. Echocardiography was not useful in providing diagnostic elements but did show preserved left ventricular function. Coronary angiography was not performed and our patient did not receive any anticoagulant treatment due to the major risk of bleeding. Magnetic resonance imaging confirmed myocardial necrosis. Our patient was managed with aspirin, a beta-blocker, an angiotensin-converting enzyme inhibitor and statin medication. The treatment was well tolerated and no ischemic recurrence was detected.</p> <p>Conclusion</p> <p>Although coronary thrombosis is a rare event in patients with fibrinogen deficiency, this condition is of major interest in view of the difficulties observed in managing these patients.</p

    High-Precision Radio and Infrared Astrometry of LSPM J1314+1320AB - II: Testing Pre--Main-Sequence Models at the Lithium Depletion Boundary with Dynamical Masses

    Get PDF
    Trent J. Dupuy, et al, 'HIGH-PRECISION RADIO AND INFRARED ASTROMETRY OF LSPM J1314+1320AB. II. TESTING PREMAIN-SEQUENCE MODELS AT THE LITHIUM DEPLETION BOUNDARY WITH DYNAMICAL MASSES', The Astrophysical Journal, Vol. 827 (1), 14pp, August 2016. doi:10.3847/0004-637X/827/1/23. © 2016. The American Astronomical Society. All rights reserved.We present novel tests of pre−-main-sequence models based on individual dynamical masses for the M7 binary LSPM J1314+1320AB. Joint analysis of our Keck adaptive optics astrometric monitoring along with Very Long Baseline Array radio data from a companion paper yield component masses of 0.0885±0.00060.0885\pm0.0006 M⊙M_{\odot} and 0.0875±0.00100.0875\pm0.0010 M⊙M_{\odot} and a parallactic distance of 17.249±0.01317.249\pm0.013 pc. We also derive component luminosities that are consistent with the system being coeval at an age of 80.8±2.580.8\pm2.5 Myr, according to BHAC15 evolutionary models. The presence of lithium is consistent with model predictions, marking the first time the theoretical lithium depletion boundary has been tested with ultracool dwarfs of known mass. However, we find that the average evolutionary model-derived effective temperature (2950±52950\pm5 K) is 180 K hotter than we derive from a spectral type−-TeffT_{\rm eff} relation based on BT-Settl models (2770±1002770\pm100 K). We suggest that the dominant source of this discrepancy is model radii being too small by ≈\approx13%. In a test that mimics the typical application of evolutionary models by observers, we derive masses on the H-R diagram using the luminosity and BT-Settl temperature. The estimated masses are 46−19+1646^{+16}_{-19}% (2.0σ\sigma) lower than we measure dynamically and would imply that this is a system of ≈\approx50 MJupM_{\rm Jup} brown dwarfs, highlighting the large systematic errors possible when inferring masses from the H-R diagram. This is first time masses have been measured for ultracool (≄\geqM6) dwarfs displaying spectral signatures of low gravity. Based on features in the infrared, LSPM J1314+1320AB appears higher gravity than typical Pleiades and AB Dor members, opposite the expectation given its younger age. The components of LSPM J1314+1320AB are now the nearest, lowest mass pre−-main-sequence stars with direct mass measurements.Peer reviewe
    • 

    corecore