2,509 research outputs found

    Gamete quality and management for in vitro fertilisation in meagre (Argyrosomus regius)

    Get PDF
    The aquaculture of meagre (Argyrosomus regius) requires methods for the control of reproduction that enable the production of families from specific individuals for selective breeding programs. We experimentally determined the parameters required for an in vitro fertilisation protocol. A total of 14 females and 5 males (mean ± S.D. weights of 20.45 ± 6.22 and 15.94 ± 2.75 kg, respectively) were used. Selected females had vitellogenic oocytes >550 μm in diameter and males had fluid sperm upon application of abdominal pressure. Both sexes were treated with an injection of 15 μg kg−1 of gonadotropin-releasing hormone agonist (GnRHa) to induce oocyte maturation/ovulation and enhance sperm production. To determine the timing of ovulation and window of high egg viability, females were stripped serially every 2.5 h beginning 35 h after GnRHa treatment. Sperm was obtained 24 h after GnRHa treatment and was diluted 1/4 in modified Leibovitz for storage at 4 °C until use. Sperm quality parameters such as percentage initial spermatozoa motility, duration of motility, velocity and density were determined using computer assisted sperm analysis (CASA). In vitro inseminations were made in duplicate or triplicate batches of eggs from each spawn by mixing 0.5–1 mL of eggs, 20–40 μL diluted sperm (pooled from two males) and 100 mL of seawater. Fertilisation success was examined at spermatozoa (spz): egg ratios between ~2000 and 400,000 spz egg−1. The optimal time for stripping ovulated females was ≤3 h after ovulation, which was the window of optimal egg viability. Ovulation under the conditions of this study was close to 38 h after GnRHa treatment, with a range from 35 to 41 h. Beginning from 3 h after ovulation, egg viability declined probably due to overripening. Sperm diluted in Leibovitz maintained motility and velocity for as long as 7 h after collection. Spermatozoa motility (%) and average path velocity (VAP, μm/s) of sperm samples obtained from males before GnRHa injection declined rapidly after activation compared to the samples obtained 24 h post-injection, with significant decreases respectively after 75 and 45 s. A minimum ratio of 150,000 spermatozoa egg−1 was necessary to ensure high fertilisation success. The acquired knowledge of the present study will aid the aquaculture industry and future research on selective breeding programs for meagre.info:eu-repo/semantics/acceptedVersio

    Radiotherapy biobanking : current landscape, opportunities, challenges, and future aspirations

    Get PDF
    This work was supported by the National Cancer Research Institute (NCRI) Clinical and Translational Radiotherapy Research Working Group (CTRad), which was established in 2009 by six of the NCRI's funding partners. We gratefully acknowledge Carolyn Chan and Julie Stock (NCRI) for their assistance in collecting the responses to the questionnaire sent to CTRad membership. Open Access via the Wiley OA AgreementPeer reviewedPublisher PD

    Tumour-infiltrating lymphocyte scores effectively stratify outcomes over and above p16 post chemo-radiotherapy in anal cancer

    No full text
    Background: The majority (90%) of anal cancers are human papillomavirus (HPV)-driven, identified using immunochemistry for p16. Compared with HPV? patients, those with HPV+ disease generally show improved survival, although relapse rates around 25% indicate a need for further stratification of this group.Methods: Using two cohorts of anal cancer, previously characterised for p16, we assessed the prognostic value of tumour-infiltrating lymphocytes (TILs).Results: Tumour-infiltrating lymphocyte scores were used to stratify p16+ cases, where tumours with absent/low levels of TIL had a relapse-free rate of 63%, as opposed to 92% with high levels of TIL (log rank P=0.006).Conclusions: Assessment of TIL adds to p16 status in the prognosis of anal cancer following chemo-radiotherapy and provides evidence of the clinical importance of the immune response

    Financial inclusion

    Get PDF
    Financial inclusion has been noted as a key driver of poverty alleviation and growth. Yet, most of the scholarly work that exists lacks a comprehensive discussion of how the poor interact with financial services and the channels through which such services can affect their livelihoods. This book offers researchers who focus on financial inclusion and African economies a one stop resource for understanding the channels of transmission for financial inclusion as well as an application of these channels through original country specific empirical papers. The book provides a back-to-basics presentation of the transmission of financial services to growth and poverty. This theoretical discussion is complemented by an empirical presentation of the various services used by the poor, with a focus on Africa. Case studies of financial inclusion in six African countries cover a broad range of topics most important to African countries and highlight the unique African setting. These empirical papers provide important learning points. Firstly, hybrid financial institutions such as cooperative financial institutions and financial social entrepreneurs are the best way to increase financial inclusion in Africa. They provide important vehicles to circumventing the restrictive and exclusive bank-based financial markets typical of African economies. Secondly, digital finance is a potent tool in improving financial access and usage in Africa, and its impact on poverty operates through both traditional and nontraditional financial instruments. Thirdly, investment in infrastructure which supports complementary markets is critical and is likely to have a greater effect on credit rationing than direct provision of credit to small businesses

    Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial)

    Get PDF
    Purpose To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. Materials and Methods In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29–85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. Results Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50–59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). Conclusion The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. © RSNA, 2015The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256

    Financial inclusion

    Get PDF
    Financial inclusion has been noted as a key driver of poverty alleviation and growth. Yet, most of the scholarly work that exists lacks a comprehensive discussion of how the poor interact with financial services and the channels through which such services can affect their livelihoods. This book offers researchers who focus on financial inclusion and African economies a one stop resource for understanding the channels of transmission for financial inclusion as well as an application of these channels through original country specific empirical papers. The book provides a back-to-basics presentation of the transmission of financial services to growth and poverty. This theoretical discussion is complemented by an empirical presentation of the various services used by the poor, with a focus on Africa. Case studies of financial inclusion in six African countries cover a broad range of topics most important to African countries and highlight the unique African setting. These empirical papers provide important learning points. Firstly, hybrid financial institutions such as cooperative financial institutions and financial social entrepreneurs are the best way to increase financial inclusion in Africa. They provide important vehicles to circumventing the restrictive and exclusive bank-based financial markets typical of African economies. Secondly, digital finance is a potent tool in improving financial access and usage in Africa, and its impact on poverty operates through both traditional and nontraditional financial instruments. Thirdly, investment in infrastructure which supports complementary markets is critical and is likely to have a greater effect on credit rationing than direct provision of credit to small businesses

    Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial).

    Get PDF
    PURPOSE: To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS: In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS: Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION: The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256
    corecore