172 research outputs found

    Electrical structure of the lithosphere from Rio de la Plata craton to Paraná basin: amalgamation of cratonic and refertilized lithospheres in SW Gondwanaland

    Get PDF
    We conducted a magnetotelluric (MT) study from Paleoproterozoic Rio de la Plata Craton, in Uruguay, toward Paleozoic-Mesozoic Paraná Basin, in Brazil. The 850-km-long MT transect comprises 35 evenly spaced broadband electromagnetic soundings sites. In the Paraná Basin, 11 additional long-period measurements were acquired to extend the maximum depth of investigation. All data were inverted using two- and three-dimensional approaches obtaining the electrical resistivity structure from the surface down to 200 km. The Rio de la Plata Craton is>200-km thick and resistive (~2,000Ωm). Its northern limit is electrically defined by a lithosphere scale lateral transition and lower crust conductive anomalies (1–10Ωm) interpreted as a Paleoproterozoic suture at the southern edge of Rivera-Taquarembó Block. The latter is characterized by an approximately 100-km thick and moderate resistive (>500Ωm) upper mantle. The Ibaré shear zone is another suture where an ocean-ocean subduction generated the 120-km thick and resistive (>1,000Ωm) São Gabriel juvenile arc. Proceeding northward, a 70- to 80-km thick, 150-km wide, and inclined resistive zone is imaged. This zone could be remnant of an oceanic lithosphere or island arcs accreted at the southern border of Paraná Basin. The MT transect terminates within the southern Paraná Basin where a 150- to 200-km-thick less resistive lithosphere (<1,000Ωm) may indicate refertilization processes during plate subduction and ocean closure in Neoproterozoic-Cambrian time. Our MT data support a tectonic model of NNE– SSW convergence for this segment of SW Gondwanaland

    An Instrument For Investigation of the Cosmic Microwave Background Radiation at Intermediate Angular Scales

    Get PDF
    We describe an off-axis microwave telescope for observations of the anisotropy in the cosmic microwave background (CMB) radiation on angular scales between 0.5 deg and 3 deg. The receiver utilizes cryogenic high-electron-mobility transistor (HEMT) amplifiers and detects the total power in multiple 3 GHz wide channels. Both frequency and polarization information are recorded allowing discrimination between CMB radiation and potential foreground sources and allowing checks for systematic effects. The instrumental radiometric offset is small (~1 mK). Data are taken by rapidly sampling while sweeping the beam many beamwidths across the sky. After detection, a spatio-temporal filter is formed in software which optimizes the sensitivity in a multipole band in the presence of atmospheric fluctuations. Observations were made from Saskatoon, Saskatchewan (SK), Canada during the winter of 1993 with six channels between 27.6 and 34.0 GHz, in 1994 with twelve channels between 27.6 and 44.1 GHz, and in 1995 with six channels between 38.2 and 44.1 GHz. The performance of the instrument and assessment of the atmospheric noise at this site are discussed.Comment: latex file is called inst.tex. 30 pages with 14 Postscript figures. Uses aas2pp4.sty (included). Submitted to Ap

    CMB Telescopes and Optical Systems

    Full text link
    The cosmic microwave background radiation (CMB) is now firmly established as a fundamental and essential probe of the geometry, constituents, and birth of the Universe. The CMB is a potent observable because it can be measured with precision and accuracy. Just as importantly, theoretical models of the Universe can predict the characteristics of the CMB to high accuracy, and those predictions can be directly compared to observations. There are multiple aspects associated with making a precise measurement. In this review, we focus on optical components for the instrumentation used to measure the CMB polarization and temperature anisotropy. We begin with an overview of general considerations for CMB observations and discuss common concepts used in the community. We next consider a variety of alternatives available for a designer of a CMB telescope. Our discussion is guided by the ground and balloon-based instruments that have been implemented over the years. In the same vein, we compare the arc-minute resolution Atacama Cosmology Telescope (ACT) and the South Pole Telescope (SPT). CMB interferometers are presented briefly. We conclude with a comparison of the four CMB satellites, Relikt, COBE, WMAP, and Planck, to demonstrate a remarkable evolution in design, sensitivity, resolution, and complexity over the past thirty years.Comment: To appear in: Planets, Stars and Stellar Systems (PSSS), Volume 1: Telescopes and Instrumentatio

    First Season QUIET Observations: Measurements of CMB Polarization Power Spectra at 43 GHz in the Multipole Range 25 <= ell <= 475

    Get PDF
    The Q/U Imaging ExperimenT (QUIET) employs coherent receivers at 43GHz and 95GHz, operating on the Chajnantor plateau in the Atacama Desert in Chile, to measure the anisotropy in the polarization of the CMB. QUIET primarily targets the B modes from primordial gravitational waves. The combination of these frequencies gives sensitivity to foreground contributions from diffuse Galactic synchrotron radiation. Between 2008 October and 2010 December, >10,000hours of data were collected, first with the 19-element 43GHz array (3458hours) and then with the 90-element 95GHz array. Each array observes the same four fields, selected for low foregrounds, together covering ~1000deg^2. This paper reports initial results from the 43GHz receiver which has an array sensitivity to CMB fluctuations of 69uK sqrt(s). The data were extensively studied with a large suite of null tests before the power spectra, determined with two independent pipelines, were examined. Analysis choices, including data selection, were modified until the null tests passed. Cross correlating maps with different telescope pointings is used to eliminate a bias. This paper reports the EE, BB and EB power spectra in the multipole range ell=25-475. With the exception of the lowest multipole bin for one of the fields, where a polarized foreground, consistent with Galactic synchrotron radiation, is detected with 3sigma significance, the E-mode spectrum is consistent with the LCDM model, confirming the only previous detection of the first acoustic peak. The B-mode spectrum is consistent with zero, leading to a measurement of the tensor-to-scalar ratio of r=0.35+1.06-0.87. The combination of a new time-stream double-demodulation technique, Mizuguchi-Dragone optics, natural sky rotation, and frequent boresight rotation leads to the lowest level of systematic contamination in the B-mode power so far reported, below the level of r=0.1Comment: 19 pages, 14 figures, higher quality figures are available at http://quiet.uchicago.edu/results/index.html; Fixed a typo and corrected statistical error values used as a reference in Figure 14, showing our systematic uncertainties (unchanged) vs. multipole; Revision to ApJ accepted version, this paper should be cited as "QUIET Collaboration et al. (2011)

    Characterization of an Ionization Readout Tile for nEXO

    Full text link
    A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} ×\times 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207^{207}Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution σ/E\sigma/E=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.Comment: 18 pages, 13 figures, as publishe

    Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay

    Full text link
    The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta (0νββ0\nu\beta\beta) decay in 136^{136}Xe with a target half-life sensitivity of approximately 102810^{28} years using 5×1035\times10^3 kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the 136^{136}Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.Comment: v2 as publishe
    corecore