32 research outputs found

    Application of non-thermal plasma reactor for degradation and detoxification of high concentrations of dye Reactive Black 5 in water

    Get PDF
    Degradation and detoxification efficiency of high concentrations of commercially available reactive textile dye Reactive Black 5 solution (40, 80, 200, 500, 1000 mg L-1), were studied. Advanced oxidation processes in water falling film based on dielectric barrier discharge in a non-thermal plasma reactor were used. For the first time, this reactor was used for the treatment of high concentrations of organic pollutants such as reactive textile dye Reactive Black 5 in water. Solution of the dye was plasma treated in a thin aqueous solution film that was constantly regenerated. The reactor works as a continuous flow reactor and the electrical discharge itself takes place at the gas-liquid interphase. The dye solution was recirculated through the reactor with an applied energy density of 0-374 kJ L-1. Decolorization efficiency (%) was monitored by UV-Vis spectrophotometry. Samples were taken after every recirculation (similar to 22 kJ L-1) and decolorization percentage was measured after 5 min and 24 h post plasma treatment. The efficiency of degradation (i.e., mineralization) and possible degradation products were also monitored by determination of the chemical oxygen demand (COD) and by ion chromatography (IC). Initial toxicity and toxicity of the solutions after the treatment were studied using Artemia salina test organisms. Efficiency of decolorization decreased with the increase of the dye concentration. Complete decolorization, high mineralization and non-toxicity of the solution ( lt 10 %) were acomplished after plasma treatment using energy density of 242 kJ L-1, while the initial concentrations of Reactive Black 5 were 40 and 80 mg L-1

    An anatomy-based lumped parameter model of cerebrospinal venous circulation: can an extracranial anatomical change impact intracranial hemodynamics?

    Get PDF
    Background The relationship between extracranial venous system abnormalities and central nervous system disorders has been recently theorized. In this paper we delve into this hypothesis by modeling the venous drainage in brain and spinal column areas and simulating the intracranial flow changes due to extracranial morphological stenoses. Methods A lumped parameter model of the cerebro-spinal venous drainage was created based on anatomical knowledge and vessels diameters and lengths taken from literature. Each vein was modeled as a hydraulic resistance, calculated through Poiseuille’s law. The inputs of the model were arterial flow rates of the intracranial, vertebral and lumbar districts. The effects of the obstruction of the main venous outflows were simulated. A database comprising 112 Multiple Sclerosis patients (Male/Female = 42/70; median age ± standard deviation = 43.7 ± 10.5 years) was retrospectively analyzed. Results The flow rate of the main veins estimated with the model was similar to the measures of 21 healthy controls (Male/Female = 10/11; mean age ± standard deviation = 31 ± 11 years), obtained with a 1.5 T Magnetic Resonance scanner. The intracranial reflux topography predicted with the model in cases of internal jugular vein diameter reduction was similar to those observed in the patients with internal jugular vein obstacles. Conclusions The proposed model can predict physiological and pathological behaviors with good fidelity. Despite the simplifications introduced in cerebrospinal venous circulation modeling, the key anatomical feature of the lumped parameter model allowed for a detailed analysis of the consequences of extracranial venous impairments on intracranial pressure and hemodynamics

    Internal Jugular Vein Cross-Sectional Area and Cerebrospinal Fluid Pulsatility in the Aqueduct of Sylvius: A Comparative Study between Healthy Subjects and Multiple Sclerosis Patients

    Get PDF
    Objectives Constricted cerebral venous outflow has been linked with increased cerebrospinal fluid (CSF) pulsatility in the aqueduct of Sylvius in multiple sclerosis (MS) patients and healthy individuals. This study investigates the relationship between CSF pulsatility and internal jugular vein (IJV) cross-sectional area (CSA) in these two groups, something previously unknown. Methods 65 relapsing-remitting MS patients (50.8% female; mean age = 43.8 years) and 74 healthy controls (HCs) (54.1% female; mean age = 43.9 years) were investigated. CSF flow quantification was performed on cine phase-contrast MRI, while IJV-CSA was calculated using magnetic resonance venography. Statistical analysis involved correlation, and partial least squares correlation analysis (PLSCA). Results PLSCA revealed a significant difference (p<0.001; effect size = 1.072) between MS patients and HCs in the positive relationship between CSF pulsatility and IJV-CSA at C5-T1, something not detected at C2-C4. Controlling for age and cardiovascular risk factors, statistical trends were identified in HCs between: increased net positive CSF flow (NPF) and increased IJV-CSA at C5-C6 (left: r = 0.374, p = 0.016; right: r = 0.364, p = 0.019) and C4 (left: r = 0.361, p = 0.020); and increased net negative CSF flow and increased left IJV-CSA at C5-C6 (r = -0.348, p = 0.026) and C4 (r = -0.324, p = 0.039), whereas in MS patients a trend was only identified between increased NPF and increased left IJV-CSA at C5-C6 (r = 0.351, p = 0.021). Overall, correlations were weaker in MS patients (p = 0.015). Conclusions In healthy adults, increased CSF pulsatility is associated with increased IJV-CSA in the lower cervix (independent of age and cardiovascular risk factors), suggesting a biomechanical link between the two. This relationship is altered in MS patients

    Risk Factors for Chronic Cerebrospinal Venous Insufficiency (CCSVI) in a Large Cohort of Volunteers

    Get PDF
    BACKGROUND: The role of intra- and extra-cranial venous system impairment in the pathogenesis of various vascular, inflammatory and neurodegenerative neurological disorders, as well as in aging, has not been studied in detail. Nor have risk factors been determined for increased susceptibility of venous pathology in the intra-cranial and extra-cranial veins. The aim of this study was to investigate the association between presence of a newly proposed vascular condition called chronic cerebrospinal venous insufficiency (CCSVI) and environmental factors in a large volunteer control group without known central nervous system pathology. METHODS AND FINDINGS: The data were collected in a prospective study from 252 subjects who were screened for medical history as part of the entry criteria and participated in the case-control study of CCSVI prevalence in multiple sclerosis (MS) patients, and then were analyzed post-hoc. All participants underwent physical and Doppler sonography examinations, and were assessed with a structured environmental questionnaire. Fullfilment of ≥ 2 positive venous hemodynamic (VH) criteria on Doppler sonography was considered indicative of CCSVI diagnosis. Risk and protective factors associated with CCSVI were analyzed using logistic regression analysis. Seventy (27.8%) subjects presented with CCSVI diagnosis and 153 (60.7%) presented with one or more VH criteria. The presence of heart disease (p = .001), especially heart murmurs (p = .007), a history of infectious mononucleosis (p = .002), and irritable bowel syndrome (p = .005) were associated with more frequent CCSVI diagnosis. Current or previous smoking (p = .029) showed a trend for association with more frequent CCSVI diagnosis, while use of dietary supplements (p = .018) showed a trend for association with less frequent CCSVI diagnosis. CONCLUSIONS: Risk factors for CCSVI differ from established risk factors for peripheral venous diseases. Vascular, infectious and inflammatory factors were associated with higher CCSVI frequency

    Caries Prevalence among 24 to 71-Month Old Children from Banja Luka

    No full text
    Background: Despite the availability of a variety of preventive and treatment modalities, caries in the early childhood remains a serious and prevalent disease worldwide

    Analysis of the intermetallic bonding between ring carrier and aluminum piston alloy

    No full text
    Analysis of the intermetallic bonding between ring carrier and aluminum piston alloy, Metallurgical & Materials Engineering Congress of South-East Europ

    Intra-and Extraluminal Structural and Functional Venous Anomalies in Multiple Sclerosis, as Evidenced by 2 Noninvasive Imaging Techniques

    No full text
    BACKGROUND AND PURPOSE: Chronic cerebrospinal venous insufficiency (CCSVI) is a vascular condition characterized by anomalies of the main extracranial cerebrospinal venous routes that interfere with normal venous outflow. Research into CCSVI will determine its sensitivity and specificity for a diagnosis of MS, its prevalence in MS patients, and its clinical, MRI, and genetic correlates. Our aim was to investigate the prevalence and number of intra-and extraluminal structural and functional extracranial venous abnormalities by using DS and MRV, in patients with MS and HCs
    corecore