23 research outputs found

    Geometrical jitter and bolometric regime in photon detection by straight superconducting nanowire

    Full text link
    We present a direct observation of the geometrical jitter in single photon detection by a straight superconducting nanowire. Differential measurement technique was applied to the 180-{\mu}m long nanowire similar to those commonly used in the technology of superconducting nanowire single photon detectors (SNSPD). A non-gaussian geometrical jitter appears as a wide almost uniform probability distribution (histogram) of the delay time (latency) of the nanowire response to detected photon. White electrical noise of the readout electronics causes broadened, Gaussian shaped edges of the histogram. Subtracting noise contribution, we found for the geometrical jitter a standard deviation of 8.5 ps and the full width at half maximum (FWHM) of the distribution of 29 ps. FWHM corresponds to the propagation speed of the electrical signal along the nanowire of 6.2×1066.2\times10^{6} m/s or 0.02 of the speed of light. Alternatively the propagation speed was estimated from the central frequency of the measured first order self-resonance of the nanowire. Both values agree well with each other and with previously reported values. As the intensity of the incident photon flux increases, the wide probability distribution collapses into a much narrower Gaussian distribution with a standard deviation dominated by the noise of electronics. We associate the collapse of the histogram with the transition from the discrete, single photon detection to the uniform bolometric regim

    Physical mechanisms of timing jitter in photon detection by current carrying superconducting nanowires

    Full text link
    We studied timing jitter in the appearance of photon counts in meandering nanowires with different fractional amount of bends. Timing jitter, which is the probability density of the random time delay between photon absorption in current-carrying superconducting nanowire and appearance of the normal domain, reveals two different underlying physical scenarios. In the deterministic regime, which is realized at large currents and photon energies, jitter is controlled by position dependent detection threshold in straight parts of meanders and decreases with the current. At small photon energies, jitter increases and its current dependence disappears. In this probabilistic regime jitter is controlled by Poisson process in that magnetic vortices jump randomly across the wire in areas adjacent to the bends.Comment: 10 pages, 2 tables, 6 figure

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    International progress and evaluation on interactive coupling effects between urbanization and the eco-environment

    Full text link

    Comparison of SNSPDs Biased With Microwave and Direct Currents

    No full text
    corecore