534 research outputs found

    SOXS: a wide band spectrograph to follow up transients

    Get PDF
    SOXS (Son Of X-Shooter) will be a spectrograph for the ESO NTT telescope capable to cover the optical and NIR bands, based on the heritage of the X-Shooter at the ESO-VLT. SOXS will be built and run by an international consortium, carrying out rapid and longer term Target of Opportunity requests on a variety of astronomical objects. SOXS will observe all kind of transient and variable sources from different surveys. These will be a mixture of fast alerts (e.g. gamma-ray bursts, gravitational waves, neutrino events), mid-term alerts (e.g. supernovae, X-ray transients), fixed time events (e.g. close-by passage of minor bodies). While the focus is on transients and variables, still there is a wide range of other astrophysical targets and science topics that will benefit from SOXS. The design foresees a spectrograph with a Resolution-Slit product ~ 4500, capable of simultaneously observing over the entire band the complete spectral range from the U- to the H-band. The limiting magnitude of R~20 (1 hr at S/N~10) is suited to study transients identified from on-going imaging surveys. Light imaging capabilities in the optical band (grizy) are also envisaged to allow for multi-band photometry of the faintest transients. This paper outlines the status of the project, now in Final Design Phase.Comment: 12 pages, 14 figures, to be published in SPIE Proceedings 1070

    Intercomparison of desert dust optical depth from satellite measurements

    Get PDF
    This work provides a comparison of satellite retrievalsof Saharan desert dust aerosol optical depth (AOD)during a strong dust event through March 2006. In this event,a large dust plume was transported over desert, vegetated,and ocean surfaces. The aim is to identify the differencesbetween current datasets. The satellite instruments consideredare AATSR, AIRS, MERIS, MISR, MODIS, OMI,POLDER, and SEVIRI. An interesting aspect is that the differentalgorithms make use of different instrument characteristicsto obtain retrievals over bright surfaces. These includemulti-angle approaches (MISR, AATSR), polarisationmeasurements (POLDER), single-view approaches using solarwavelengths (OMI, MODIS), and the thermal infraredspectral region (SEVIRI, AIRS). Differences between instruments,together with the comparison of different retrievalalgorithms applied to measurements from the same instrument,provide a unique insight into the performance andcharacteristics of the various techniques employed. As wellas the intercomparison between different satellite products,the AODs have also been compared to co-located AERONETdata. Despite the fact that the agreement between satellite andAERONET AODs is reasonably good for all of the datasets,there are significant differences between them when comparedto each other, especially over land. These differencesare partially due to differences in the algorithms, such as assumptionsabout aerosol model and surface properties. However,in this comparison of spatially and temporally averageddata, it is important to note that differences in sampling, relatedto the actual footprint of each instrument on the heterogeneousaerosol field, cloud identification and the qualitycontrol flags of each dataset can be an important issue

    Two different charge-separation pathways in photosystem II

    Get PDF
    Charge separation is an essential step in the conversion of solar energy into chemical energy in photosynthesis. To investigate this process, we performed transient absorption experiments at 77 K with various excitation conditions on the isolated Photosystem II reaction center preparations from spinach. The results have been analyzed by global and target analysis and demonstrate that at least two different excited states, (Ch

    Home use of a bihormonal bionic pancreas versus insulin pump therapy in adults with type 1 diabetes: a multicentre randomised crossover trial

    Get PDF
    The safety and effectiveness of a continuous, day-and-night automated glycaemic control system using insulin and glucagon has not been shown in a free-living, home-use setting. We aimed to assess whether bihormonal bionic pancreas initialised only with body mass can safely reduce mean glycaemia and hypoglycaemia in adults with type 1 diabetes who were living at home and participating in their normal daily routines without restrictions on diet or physical activity

    Slow Dissociation of a Charged Ligand: Analysis of the Primary Quinone QA Site of Photosynthetic Bacterial Reaction Centers

    Get PDF
    Reaction centers (RCs) are integral membrane proteins that undergo a series of electron transfer reactions during the process of photosynthesis. In the QA site of RCs from Rhodobacter sphaeroides, ubiquinone-10 is reduced, by a single electron transfer, to its semiquinone. The neutral quinone and anionic semiquinone have similar affinities, which is required for correct in situ reaction thermodynamics. A previous study showed that despite similar affinities, anionic quinones associate and dissociate from the QA site at rates ≈104 times slower than neutral quinones indicating that anionic quinones encounter larger binding barriers (Madeo, J.; Gunner, M. R. Modeling binding kinetics at the QA site in bacterial reaction centers. Biochemistry2005, 44, 10994–11004). The present study investigates these barriers computationally, using steered molecular dynamics (SMD) to model the unbinding of neutral ground state ubiquinone (UQ) and its reduced anionic semiquinone (SQ–) from the QA site. In agreement with experiment, the SMD unbinding barrier for SQ– is larger than for UQ. Multi Conformational Continuum Electrostatics (MCCE), used here to calculate the binding energy, shows that SQ– and UQ have comparable affinities. In the QA site, there are stronger binding interactions for SQ– compared to UQ, especially electrostatic attraction to a bound non-heme Fe2+. These interactions compensate for the higher SQ– desolvation penalty, allowing both redox states to have similar affinities. These additional interactions also increase the dissociation barrier for SQ– relative to UQ. Thus, the slower SQ– dissociation rate is a direct physical consequence of the additional binding interactions required to achieve a QA site affinity similar to that of UQ. By a similar mechanism, the slower association rate is caused by stronger interactions between SQ– and the polar solvent. Thus, stronger interactions for both the unbound and bound states of charged and highly polar ligands can slow their binding kinetics without a conformational gate. Implications of this for other systems are discussed

    Phase II trial of Modified Vaccinia Ankara (MVA) virus expressing 5T4 and high dose Interleukin-2 (IL-2) in patients with metastatic renal cell carcinoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Interleukin-2 (IL-2) induces durable objective responses in a small cohort of patients with metastatic renal cell carcinoma (RCC) but the antigen(s) responsible for tumor rejection are not known. 5T4 is a non-secreted membrane glycoprotein expressed on clear cell and papillary RCCs. A modified vaccinia virus Ankara (MVA) encoding 5T4 was tested in combination with high-dose IL-2 to determine the safety, objective response rate and effect on humoral and cell-mediated immunity.</p> <p>Methods</p> <p>25 patients with metastatic RCC who qualified for IL-2 were eligible and received three immunizations every three weeks followed by IL-2 (600,000 IU/kg) after the second and third vaccinations. Blood was collected for analysis of humoral, effector and regulatory T cell responses.</p> <p>Results</p> <p>There were no serious vaccine-related adverse events. While no objective responses were observed, three patients (12%) were rendered disease-free after nephrectomy or resection of residual metastatic disease. Twelve patients (48%) had stable disease which was associated with improved median overall survival compared to patients with progressive disease (not reached vs. 28 months, p = 0.0261). All patients developed 5T4-specific antibody responses and 13 patients had an increase in 5T4-specific T cell responses. Although the baseline frequency of Tregs was elevated in all patients, those with stable disease showed a trend toward increased effector CD8+ T cells and a decrease in Tregs.</p> <p>Conclusion</p> <p><b>V</b>accination with MVA-5T4 did not improve objective response rates of IL-2 therapy but did result in stable disease associated with an increase in the ratio of 5T4-specific effector to regulatory T cells in selected patients.</p> <p>Trial registration number</p> <p>ISRCTN83977250</p

    Son of X--Shooter: a multi--band instrument for a multi--band universe

    Get PDF
    Son Of X-Shooter (SOXS) will be a new instrument designed to be mounted at the Nasmyth--A focus of the ESO 3.5 m New Technology Telescope in La Silla site (Chile). SOXS is composed of two high-efficiency spectrographs with a resolution slit product 4500, working in the visible (350 -- 850 nm) and NIR (800 -- 2000 nm) range respectively, and a light imager in the visible (the acquisition camera usable also for scientific purposes). The science case is very broad, it ranges from moving minor bodies in the solar system, to bursting young stellar objects, cataclysmic variables and X-ray binary transients in our Galaxy, supernovae and tidal disruption events in the local Universe, up to gamma-ray bursts in the very distant and young Universe, basically encompassing all distance scales and astronomy branches. At the moment, the instrument passed the Preliminary Design Review by ESO (July 2017) and the Final Design (with FDR in July 2018).Comment: 23 pages, 10 Figures, accepted to be published in Frontier Research in Astrophysics 2018 Conference proceedings in Proceeding of Science. arXiv admin note: text overlap with arXiv:1807.0882
    corecore