710 research outputs found
Population studies on Phytophthora infestans on potatoes and tomatoes in southern Germany
Fifty-seven isolates of Phytophthora infestans from blighted potato foliage were collected in 1995 in southern Germany and analysed for mating type and sensitivity to metalaxyl. Fifty-six of them were characterised as A1 and one as A2 mating types. Resistance to metalaxyl was observed frequently: 53 isolates were resistant, three were partially sensitive, and one was sensitive. In a subsequent field study in 1999, 84 isolates collected from blighted potato and tomato foliage were analysed for mating type. Seventy-two were characterised as A1 and twelve as A2 mating types. The response of 76 isolates to metalaxyl and to propamocarb was tested. The majority (42) of the 76 isolates was classified as resistant to metalaxyl; 31 were partially sensitive and only three isolates were sensitive. The results with propamocarb were less discrete; 10 isolates were classified as resistant and three were clearly sensitive. AFLP fingerprinting was used to examine the genetic structure of the southern German P. infestans population collected in 1999 and indicated that the tested population can be sub-divided into a tomato group, a potato group and a mixed group containing isolates collected from both crops. The presence of Ia and IIa mitochondrial DNA haplotypes indicates that the German P. infestans isolates belong to the new pathogen population that has also been reported in neighbouring regions of Europe. The present study indicates that at the beginning of the season only a few genotypes were present, and the population became genetically more variable at the end of the growing season
Chiral Symmetry Restoration in the Schwinger Model with Domain Wall Fermions
Domain Wall Fermions utilize an extra space time dimension to provide a
method for restoring the regularization induced chiral symmetry breaking in
lattice vector gauge theories even at finite lattice spacing. The breaking is
restored at an exponential rate as the size of the extra dimension increases.
Before this method can be used in dynamical simulations of lattice QCD, the
dependence of the restoration rate to the other parameters of the theory and,
in particular, the lattice spacing must be investigated. In this paper such an
investigation is carried out in the context of the two flavor lattice Schwinger
model.Comment: LaTeX, 37 pages including 18 figures. Added comments regarding power
law fitting in sect 7. Also, few changes were made to elucidate the content
in sect. 5.1 and 5.3. To appear in Phys. Rev.
Are Audience Response Systems Worth the Cost? Comparing Question-Driven Teaching Strategies for Emergency Medical Technician Education
Purpose: As Emergency Medical Technician educators develop curricula to meet new national educational standards, effective teaching strategies validated for course content and unique student demographics are warranted. Three methods for answering multiple choice questions presented during lectures were compared: a) Audience Response System (ARS, clickers), b) hand-raising-with-eyes-closed (no-cost option), and c) passive response (no-cost option). The purpose was to determine if using the ARS resulted in improved exam scores. Method: 113 Emergency Medical Technician (EMT) students participated in this cross-over, block randomized, controlled trial, which was incorporated into their Cardiac Emergencies and Pulmonary Emergencies course lectures. Students took pretests, immediate post-tests, and delayed post-tests composed of multiple choice questions that targeted either lower or higher order thinking. Results: For both lectures, there were significant improvements on all immediate post-test scores compared to all pretest scores (p Conclusions: In this cohort, incorporation of no-cost question-driven teaching strategies into lectures was as effective as an ARS at encouraging significant, immediate and sustained improvements in answering multiple choice questions
Gap Domain Wall Fermions
I demonstrate that the chiral properties of Domain Wall Fermions (DWF) in the
large to intermediate lattice spacing regime of QCD, 1 to 2 GeV, are
significantly improved by adding to the action two standard Wilson fermions
with supercritical mass equal to the negative DWF five dimensional mass. Using
quenched DWF simulations I show that the eigenvalue spectrum of the transfer
matrix Hamiltonian develops a substantial gap and that the residual mass
decreases appreciatively. Furthermore, I confirm that topology changing remains
active and that the hadron spectrum of the added Wilson fermions is above the
lattice cutoff and therefore is irrelevant. I argue that this result should
also hold for dynamical DWF and furthermore that it should improve the chiral
properties of related fermion methods.Comment: 12 pages of text, 14 figures, added sect.6 on topology and reference
Charakterisierung hybrider Komposit-Metall-Strukturen: Ermittlung einer Prüfmethode
Politische Anforderungen an striktere Abgasemissionen und der Elektrifizierungswille im Mobilitätssektor treiben das Bestreben nach Leichtbaustrukturen weiter an. Eine Möglichkeit, Leichtbau zu betreiben, ist das Anbringen von sogenannten Patches aus faserverstärktem Kunststoff (FVK) zur lokalen Verstärkung des Metalls. Dabei wird ein FVK-Tape aus thermoplastischer Matrix und kontinuierlichen, unidirektionalen Fasern mit entsprechender Faserorientierung durch das wärmeunterstützte Pressfügen mit dem Metall vereint. Potenzielle Einsatzgebiete derartiger Hybridstrukturen sind die B-Säule als Strukturelement oder Beplankungselemente (Motorhaube etc.) als semi-strukturelle Bauteile, für welche die Biegung auslegungskritisch ist.
Allerdings existieren keine genormten Prüfmethoden für die neu geschaffene Material-klasse, womit sich die Vergleichbarkeit verschiedener Materialien und die Vorausle-gung schwierig gestaltet. Ferner liegen keine charakteristischen Kennwerte vor, die den hybriden Verbund beschreiben. Das Anwenden von bekannten Prüfmethoden zur Kenn-wertermittlung ist aufgrund der Anisotropie und der Asymmetrie des Probenaufbaus möglich, schränkt aber die Interpretation der Ergebnisse ein. Um das Verständnis der hybriden Strukturen zu erweitern und einen ersten Schritt in Richtung eines standardi-sierten Prüfprozesses zu veranlassen, wird die Dreipunkt-Biegeprüfung als Referenz-versuch herangezogen. Zunächst werden sowohl unterschiedliche Probendicken als auch verschiedene Probenpositionen untersucht und deren Auswirkungen auf die Bie-gesteifigkeit und -festigkeit beurteilt
Exact solution (by algebraic methods) of the lattice Schwinger model in the strong-coupling regime
Using the monomer--dimer representation of the lattice Schwinger model, with
Wilson fermions in the strong--coupling regime (), we
evaluate its partition function, , exactly on finite lattices. By studying
the zeroes of in the complex plane for a large number of
small lattices, we find the zeroes closest to the real axis for infinite
stripes in temporal direction and spatial extent and 3. We find evidence
for the existence of a critical value for the hopping parameter in the
thermodynamic limit on the real axis at about . By looking at the behaviour of quantities, such as the chiral
condensate, the chiral susceptibility and the third derivative of with
respect to , close to the critical point , we find some indications
for a continuous phase transition.Comment: 22 pages (6 figures
Bestimmung der Haftfestigkeit von aufgedampften, metallischen Dickschichten auf Polymersubstrat
Inaktivkomponenten in der Batterieherstellung, wie z. B. Stromsammler, Separator oder die Kontaktierungstaps rücken zunehmend in den Fokus der Forschung. Der Wechsel zu leichteren und günstigeren Materialien ist Gegenstand aktueller Forschungsarbeiten. In diesem Zusammenhang wird auch das Potential von Verbundstromkollektoren näher betrachtet. Dabei handelt es sich um Polymerfolien, die beidseitig mit 0,5 µm bis 1,5 µm dicken Aluminium- oder Kupferschichten metallisiert sind. Als Verbundmaterial müssen dabei im Vergleich zu konventionellen, metallischen Stromkollektoren zusätzliche Materialeigenschaften betrachtet werden. Dazu gehört vor allem die
Haftfestigkeit der metallischen Beschichtungen auf den Folien. Es muss ausgeschlossen werden, dass durch wechselnde mechanische Beanspruchungen oder chemische Wechselwirkungen (z.B. mit dem Elektrolyten) in der Li-Ionen-Batteriezelle
Delaminationen auftreten und sich die Metallisierung ablöst. Dazu ist eine quantitative Methode zur Bestimmung der Haftfestigkeit notwendig. Nur so kann eine Korrelation zwischen der Haftfestigkeit und dem Verhalten in der Zelle hergestellt werden. Bisherige Versuchsmethoden decken den Anwendungsfall von beidseitig metallisierten Polymersubstraten als Stromkollektorfolie jedoch nicht ab. Aus diesem Grund werden in dieser Studie Prüfverfahren zur Bestimmung der Haftfestigkeit, die bereits in Normen spezifiziert werden, zur Bewertung der Haftfestigkeiten der Verbundfolien adaptiert und bewertet. Die betrachteten Verfahren umfassen Schälversuche, Stirnabzugs- und Zugschertests, welche hinsichtlich ihrer Eignung zur Beurteilung der Haftfestigkeit von Verbundstromkollektoren evaluiert werden. Dabei werden Verbundfolien mit unterschiedlicher Schicht- sowie Substratdicke und variierendem Beschichtungsmaterial berücksichtigt, sodass die Sensitivität der Verfahren zur Bestimmung der Haftfestigkeit aufgelöst und darauf aufbauend deren Eignung zur Charakterisierung der Verbundfolien bewertet werden kann
- …