68 research outputs found

    Using the CERN generic Windows infrastructure in a specific control environment

    Get PDF
    CERN has a large Windows 95/NT infrastructure with more than 3500 PCs connected that is used as one of the main information services for the laboratory. This infrastructure is used for a wide set of services, including Office Automation, Computing Aided Engineering, Calculations, Software Development, and ... controls. This paper will describe the CERN generic infrastructure for Windows 95 and Windows NT and then give several examples of PC control applications and future directions. The implementation of an object oriented device server based on Windows NT and ActiveX in the CERN ISOLDE-REX experiment will be reported

    The evolution of the ISOLDE control system

    Get PDF
    The ISOLDE on-line mass separator facility is operating on a Personal Computer based control system since spring 1992. Front End Computers accessing the hardware are controlled from consoles running Microsoft WindowsTM through a Novell NetWare4TM local area network. The control system is transparently integrated in the CERN wide office network and makes heavy use of the CERN standard office application programs to control and to document the running of the ISOLDE isotope separators. This paper recalls the architecture of the control system, shows its recent developments and gives some examples of its graphical user interface

    Status of the REX-ISOLDE project

    Get PDF
    The radioactive beam experiment REX-ISOLDE, a pilot experiment testing a new concept of post acceleration of radioactive ions at ISOLDE/CERN is in progress. Singly charged radioactive ions delivered by the online mass separator ISOLDE are accumulated in a Penning trap (REX trap), charge bred in an electron beam ion source (EBIS), separated from the residual gas in a mass separator and then accelerated in a linac with output energies between 0.8 and 2.2 MeV /u. The REX trap is in operation, a first test beam was already injected. The design phase of the EBIS is finished and the construction has been started. The superconducting magnet is delivered. The linac consists of a radiofrequency quadrupole (RFQ) accelerator, an interdigital IH-structure and 3 seven gap resonators to vary the final energy. (12 refs)

    Primary leptomeningeal plasmablastic lymphoma

    Get PDF
    Lymphomas that develop in human immunodeficiency virus (HIV) infected patients are predominantly aggressive B-cells lymphomas. The most common HIV-associated lymphomas include Burkitt lymphoma, diffuse large B-cell lymphoma (that often involves the CNS), primary effusion lymphoma, and plasmablastic lymphoma (PBL). Of these, PBL is relatively uncommon and displays a distinct affinity for presentation in the oral cavity. In this manuscript we report a previously undescribed primary leptomeningeal form of PBL in a patient with acquired immunodeficiency syndrome. A 40-year-old HIV positive man presented with acute onset confusion, emesis, and altered mental status. Lumbar puncture showed numerous nucleated cells with atypical plasmocyte predominance. CSF flowcytometry showed kappa restriction with CD8 and CD38 positivity and negative lymphocyte markers, while the MRI showed diffuse leptomeningeal enhancement. As the extensive systemic work-up failed to reveal any disease outside the brain, an en bloc diagnostic brain and meningeal biopsy was performed. The biopsy specimen showed sheets of plasmacytoid cells with one or more large nuclei, prominent nuclear chromatin, scattered mitoses, and abundant cytoplasm, highly suggestive of plasmablastic lymphoma. HIV-associated malignancies have protean and often confusing presentations, which pose diagnostic difficulties posed to the practicing neurological-surgeons. Even in cases where an infectious cause is suspected for the meningeal enhancement, neoplastic involvement should be considered, and cytology and flow-cytometry should be routinely ordered on the CSF samples

    Status Update and Interim Results from the Asymptomatic Carotid Surgery Trial-2 (ACST-2)

    Get PDF
    Objectives: ACST-2 is currently the largest trial ever conducted to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in patients with severe asymptomatic carotid stenosis requiring revascularization. Methods: Patients are entered into ACST-2 when revascularization is felt to be clearly indicated, when CEA and CAS are both possible, but where there is substantial uncertainty as to which is most appropriate. Trial surgeons and interventionalists are expected to use their usual techniques and CE-approved devices. We report baseline characteristics and blinded combined interim results for 30-day mortality and major morbidity for 986 patients in the ongoing trial up to September 2012. Results: A total of 986 patients (687 men, 299 women), mean age 68.7 years (SD ± 8.1) were randomized equally to CEA or CAS. Most (96%) had ipsilateral stenosis of 70-99% (median 80%) with contralateral stenoses of 50-99% in 30% and contralateral occlusion in 8%. Patients were on appropriate medical treatment. For 691 patients undergoing intervention with at least 1-month follow-up and Rankin scoring at 6 months for any stroke, the overall serious cardiovascular event rate of periprocedural (within 30 days) disabling stroke, fatal myocardial infarction, and death at 30 days was 1.0%. Conclusions: Early ACST-2 results suggest contemporary carotid intervention for asymptomatic stenosis has a low risk of serious morbidity and mortality, on par with other recent trials. The trial continues to recruit, to monitor periprocedural events and all types of stroke, aiming to randomize up to 5,000 patients to determine any differential outcomes between interventions. Clinical trial: ISRCTN21144362. © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved

    Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy

    Get PDF
    Background: Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods: ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligible if they had severe unilateral or bilateral carotid artery stenosis and both doctor and patient agreed that a carotid procedure should be undertaken, but they were substantially uncertain which one to choose. Patients were randomly allocated to CAS or CEA and followed up at 1 month and then annually, for a mean 5 years. Procedural events were those within 30 days of the intervention. Intention-to-treat analyses are provided. Analyses including procedural hazards use tabular methods. Analyses and meta-analyses of non-procedural strokes use Kaplan-Meier and log-rank methods. The trial is registered with the ISRCTN registry, ISRCTN21144362. Findings: Between Jan 15, 2008, and Dec 31, 2020, 3625 patients in 130 centres were randomly allocated, 1811 to CAS and 1814 to CEA, with good compliance, good medical therapy and a mean 5 years of follow-up. Overall, 1% had disabling stroke or death procedurally (15 allocated to CAS and 18 to CEA) and 2% had non-disabling procedural stroke (48 allocated to CAS and 29 to CEA). Kaplan-Meier estimates of 5-year non-procedural stroke were 2·5% in each group for fatal or disabling stroke, and 5·3% with CAS versus 4·5% with CEA for any stroke (rate ratio [RR] 1·16, 95% CI 0·86–1·57; p=0·33). Combining RRs for any non-procedural stroke in all CAS versus CEA trials, the RR was similar in symptomatic and asymptomatic patients (overall RR 1·11, 95% CI 0·91–1·32; p=0·21). Interpretation: Serious complications are similarly uncommon after competent CAS and CEA, and the long-term effects of these two carotid artery procedures on fatal or disabling stroke are comparable. Funding: UK Medical Research Council and Health Technology Assessment Programme

    Integrating the New Generation of Isolde Controls into a Multi-Platform Environment

    No full text
    The CERN ISOLDE isotope separator facility has been relocated on the PS Booster machine and commissioned in spring 1992. Since then, the Isolde equipment is controlled by Front End Computers running DOS and desktop PCs, also named consoles, running Windows 3.1 as graphical user interface. Because of the success of the powerful development tools used at Isolde on the Windows platform (Visual Basic, Excel...), the desktop architecture has been extended to access the UNIX based PS control system through an access controlled ³gateway² computer. Linked to the introduction of Windows 95 at CERN, the Console - Equipment (FEC) computer communication model has been redesigned with enhanced performances and new features. The gradual replacement of IPX/SPX by TCP/IP as client-server communication protocol created new perspectives, like equipment access from the World Wide Web or through a wireless telephone connection. This report will explain the evolution from the initial ISOLDE control system up to its integration in a multiple platform environment

    AAC performance check with removed poor shots

    No full text
    corecore