4,886 research outputs found

    Characteristics of GaInNAsSb VCSELs operating near 1.55Āµm

    Get PDF
    A detailed study of the high-power pulsed operation of C-band optically-pumped GaInNAsSb vertical cavity surface emitting lasers is reported. The devices employ a resonant periodic gain structure grown by molecular beam epitaxy on a GaAs substrate with a 31-pair GaAs/AlAs bottom distributed Bragg reflector and a 4-Ī», GaAs-based resonant cavity containing 10 GaInNAsSb quantum wells distributed among the 7 antinodes of the electric field. A dual-pump-band SiO2/TiO2 dielectric top mirror allows efficient optical pumping via low reflectivities at 808nm and 1064nm while providing very high reflectivity at the 1.55Ī¼m target emission wavelength. The laser characteristics were evaluated using both a Q-switched Nd:YAG 1064nm pump and a 20W-peak 180ns-pulsed 850nm diode laser. The importance of the gain-cavity detuning was evident from time-dependent spectral measurements of laser material subjected to post-growth annealing at different temperatures between 725 and 775Ā°C. The highest annealing temperature produces the largest blue shift of the gain peak relative to the cavity resonance, resulting in the best power transfer characteristics as well as reduced temperature sensitivity

    Requirements for Modeling and Simulation for Space Medicine Operations: Preliminary Considerations

    Get PDF
    The NASA Space Medicine program is now developing plans for more extensive use of high-fidelity medical Simulation systems. The use of simulation is seen as means to more effectively use the limited time available for astronaut medical training. Training systems should be adaptable for use in a variety of training environments, including classrooms or laboratories, space vehicle mockups, analog environments, and in microgravity. Modeling and simulation can also provide the space medicine development program a mechanism for evaluation of other medical technologies under operationally realistic conditions. Systems and procedures need preflight verification with ground-based testing. Traditionally, component testing has been accomplished, but practical means for "human in the loop" verification of patient care systems have been lacking. Medical modeling and simulation technology offer potential means to accomplish such validation work. Initial considerations in the development of functional requirements and design standards for simulation systems for space medicine are discussed

    1.6 W continuous-wave Raman laser using low-loss synthetic diamond

    Get PDF
    Low-birefringence (Ī”n<2x10āˆ’6), low-loss (absorption coefficient <0.006cmāˆ’1 at 1064nm), single-crystal, synthetic diamond has been exploited in a CW Raman laser. The diamond Raman laser was intracavity pumped within a Nd:YVO4 laser. At the Raman laser wavelength of 1240nm, CW output powers of 1.6W and a slope efficiency with respect to the absorbed diode-laser pump power (at 808nm) of ~18% were measured. In quasi-CW operation, maximum on-time output powers of 2.8W (slope efficiency ~24%) were observed, resulting in an absorbed diode-laser pump power to the Raman laser output power conversion efficiency of 13%

    Active-matrix GaN micro light-emitting diode display with unprecedented brightness

    Get PDF
    Displays based on microsized gallium nitride light-emitting diodes possess extraordinary brightness. It is demonstrated here both theoretically and experimentally that the layout of the n-contact in these devices is important for the best device performance. We highlight, in particular, the significance of a nonthermal increase of differential resistance upon multipixel operation. These findings underpin the realization of a blue microdisplay with a luminance of 10ā¶ cd/mĀ²

    Continuous-wave Raman laser pumped within a semiconductor disk laser cavity

    Get PDF
    A KGd(WO4)(2) Raman laser was pumped within the cavity of a cw diode-pumped InGaAs semiconductor disk laser (SDL). The Raman laser threshold was reached for 5: 6W of absorbed diode pump power, and output power up to 0.8W at 1143nm, with optical conversion efficiency of 7.5% with respect to the absorbed diode pump power, was demonstrated. Tuning the SDL resulted in tuning of the Raman laser output between 1133 and 1157nm

    Thermal and optical characterization of micro-LED probes for in vivo optogenetic neural stimulation

    Get PDF
    Within optogenetics there is a need for compact light sources that are capable of delivering light with excellent spatial, temporal, and spectral resolution to deep brain structures. Here, we demonstrate a custom GaN-based LED probe for such applications and the electrical, optical, and thermal properties are analyzed. The output power density and emission spectrum were found to be suitable for stimulating channelrhodopsin-2, one of the most common light-sensitive proteins currently used in optogenetics. The LED device produced high light intensities, far in excess of those required to stimulate the light-sensitive proteins within the neurons. Thermal performance was also investigated, illustrating that a broad range of operating regimes in pulsed mode are accessible while keeping a minimum increase in temperature for the brain (0.5Ā°C). This type of custom device represents a significant step forward for the optogenetics community, allowing multiple bright excitation sites along the length of a minimally invasive neural probe
    • ā€¦
    corecore