7 research outputs found

    “Learning on a chip:” Microfluidics for formal and informal science education

    Get PDF
    © 2019 Author(s). Microfluidics is a technique for the handling of small volumes of liquids on the order of picoliters to nanoliters and has impact for miniaturized biomedical science and fundamental research. Because of its multi- and interdisciplinary nature (i.e., combining the fields of biology, chemistry, physics, and engineering), microfluidics offers much potential for educational applications, both at the university level as well as primary and secondary education. Microfluidics is also an ideal "tool" to enthuse and educate members of the general public about the interdisciplinary aspects of modern sciences, including concepts of science, technology, engineering, and mathematics subjects such as (bio)engineering, chemistry, and biomedical sciences. Here, we provide an overview of approaches that have been taken to make microfluidics accessible for formal and informal learning. We also point out future avenues and desired developments. At the extreme ends, we can distinguish between projects that teach how to build microfluidic devices vs projects that make various microscopic phenomena (e.g., low Reynolds number hydrodynamics, microbiology) accessible to learners and the general public. Microfluidics also enables educators to make experiments low-cost and scalable, and thereby widely accessible. Our goal for this review is to assist academic researchers working in the field of microfluidics and lab-on-a-chip technologies as well as educators with translating research from the laboratory into the lecture hall, teaching laboratory, or public sphere

    A digital microfluidic system for serological immunoassays in remote settings

    Get PDF
    Serosurveys are useful for assessing population susceptibility to vaccine-preventable disease outbreaks. Although at-risk populations in remote areas could benefit from this type of information, they face several logistical barriers to implementation, such as lack of access to centralized laboratories, cold storage, and transport of samples. We describe a potential solution: a compact and portable, field-deployable, point-of-care system relying on digital microfluidics that can rapidly test a small volume of capillary blood for disease-specific antibodies. This system uses inexpensive, inkjet-printed digital microfluidic cartridges together with an integrated instrument to perform enzyme-linked immunosorbent assays (ELISAs). We performed a field validation of the system’s analytical performance at Kakuma refugee camp, a remote setting in northwestern Kenya, where we tested children aged 9 to 59 months and caregivers for measles and rubella immunoglobulin G (IgG). The IgG assays were determined to have sensitivities of 86% [95% confidence interval (CI), 79 to 91% (measles)] and 81% [95% CI, 73 to 88% (rubella)] and specificities of 80% [95% CI, 49 to 94% (measles)] and 91% [95% CI, 76 to 97% (rubella)] (measles, n = 140; rubella, n = 135) compared with reference tests (measles IgG and rubella IgG ELISAs from Siemens Enzygnost) conducted in a centralized laboratory. These results demonstrate a potential role for this point-of-care system in global serological surveillance, particularly in remote areas with limited access to centralized laboratories

    Real-Time Respiration Changes as a Viability Indicator for Rapid Antibiotic Susceptibility Testing in a Microfluidic Chamber Array

    No full text
    Rapid identification of a pathogen and the measurement of its antibiotic susceptibility are key elements in the diagnostic process of bacterial infections. Microfluidic technologies offer great control over handling and manipulation of low sample volumes with the possibility to study microbial cultures on the single-cell level. Downscaling the dimensions of cultivation systems directly results in a lower number of bacteria required for antibiotic susceptibility testing (AST) and thus in a reduction of the time to result. The developed platform presented in this work allows the reading of pathogen resistance profiles within 2–3 h based on the changes of dissolved oxygen levels during bacterial cultivation. The platform contains hundreds of individual growth chambers prefilled with a hydrogel containing oxygen-sensing nanoprobes and different concentrations of antibiotic compounds. The performance of the developed platform is tested using quality control Escherichia coli strains (ATCC 25922 and ATCC 35218) in response to clinically relevant antibiotics. The results are in agreement with values given in reference guidelines and independent measurements using a clinical AST protocol. Finally, the platform is successfully used for the AST of an E. coli clinical isolate obtained from a patient blood culture.ISSN:2379-369

    Digital Microfluidics for Immunoprecipitation

    No full text
    Immunoprecipitation (IP) is a common method for isolating a targeted protein from a complex sample such as blood, serum, or cell lysate. In particular, IP is often used as the primary means of target purification for the analysis by mass spectrometry of novel biologically derived pharmaceuticals, with particular utility for the identification of molecules bound to a protein target. Unfortunately, IP is a labor-intensive technique, is difficult to perform in parallel, and has limited options for automation. Furthermore, the technique is typically limited to large sample volumes, making the application of IP cleanup to precious samples nearly impossible. In recognition of these challenges, we introduce a method for performing microscale IP using magnetic particles and digital microfluidics (DMF-IP). The new method allows for 80% recovery of model proteins from approximately microliter volumes of serum in a sample-to-answer run time of approximately 25 min. Uniquely, analytes are eluted from these small samples in a format compatible with direct analysis by mass spectrometry. To extend the technique to be useful for large samples, we also developed a macro-to-microscale interface called preconcentration using liquid intake by paper (P-CLIP). This technique allows for efficient analysis of samples >100Ă— larger than are typically processed on microfluidic devices. As described herein, DMF-IP and P-CLIP-DMF-IP are rapid, automated, and multiplexed methods that have the potential to reduce the time and effort required for IP sample preparations with applications in the fields of pharmacy, biomarker discovery, and protein biology

    Use of a rapid digital microfluidics-powered immunoassay for assessing measles and rubella infection and immunity in outbreak settings in the Democratic Republic of the Congo.

    No full text
    The Democratic Republic of the Congo (DRC) has a high measles incidence despite elimination efforts and has yet to introduce rubella vaccine. We evaluated the performance of a prototype rapid digital microfluidics powered (DMF) enzyme-linked immunoassay (ELISA) assessing measles and rubella infection, by testing for immunoglobulin M (IgM), and immunity from natural infection or vaccine, by testing immunoglobulin G (IgG), in outbreak settings. Field evaluations were conducted during September 2017, in Kinshasa province, DRC. Blood specimens were collected during an outbreak investigation of suspected measles cases and tested for measles and rubella IgM and IgG using the DMF-ELISA in the field. Simultaneously, a household serosurvey for measles and rubella IgG was conducted in a recently confirmed measles outbreak area. DMF-ELISA results were compared with reference ELISA results tested at DRC's National Public Health Laboratory and the US Centers for Disease Control and Prevention. Of 157 suspected measles cases, rubella IgM was detected in 54% while measles IgM was detected in 13%. Measles IgG-positive cases were higher among vaccinated persons (87%) than unvaccinated persons (72%). In the recent measles outbreak area, measles IgG seroprevalence was 93% overall, while rubella seroprevalence was lower for children (77%) than women (98%). Compared with reference ELISA, DMF-ELISA sensitivity and specificity were 82% and 78% for measles IgG; 88% and 89% for measles IgM; 85% and 85% for rubella IgG; and 81% and 83% for rubella IgM, respectively. Rubella infection was detected in more than half of persons meeting the suspected measles case definition during a presumed measles outbreak, suggesting substantial unrecognized rubella incidence, and highlighting the need for rubella vaccine introduction into the national schedule. The performance of the DMF-ELISA suggested that this technology can be used to develop rapid diagnostic tests for measles and rubella

    Electrochemistry, biosensors and microfluidics: a convergence of fields

    No full text
    corecore